Lincoln Electric IM892-C Parameter Definition 503 Memory Button Disable, Mode Select Panel Lock

Page 47

B-31

 

OPERATION

B-31

 

 

 

 

 

 

 

 

 

 

 

USER DEFINED PARAMETERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Definition

 

 

 

 

 

 

 

 

 

 

P.503

Memory Button Disable

 

 

 

 

 

 

Disables the specified memory button(s). When a memory is disabled, welding procedures can-

 

 

 

 

 

not be restored from or saved to that memory. If an attempt is made to save or restore a dis-

 

 

 

 

 

abled memory, a message will be displayed on the Mode Select Panel indicating the memory

 

 

 

 

 

number is disabled. In multi-head systems, this parameter disables the same memory buttons

 

 

 

 

 

on both feed heads. This parameter can only be accessed using Weld Manager or Power

 

 

 

 

 

Wave Manager software.

 

 

 

 

 

 

 

 

 

 

P.504

Mode Select Panel Lock

 

 

 

 

 

 

Selects between several Mode Select Panel lockout preferences. When a Mode Select Panel

 

 

 

 

 

selection is locked and an attempt is made to change that parameter, a message will be dis-

 

 

 

 

 

played on the Mode Select Panel indicating the parameter is locked.

 

 

 

 

 

 

• All MSP Options Unlocked = All adjustable parameters on the Mode Select Panel are

 

 

 

 

 

unlocked.

 

 

 

 

 

 

• All MSP Options Locked = All knobs and buttons on the Mode Select Panel are locked.

 

 

 

 

 

 

• Start & End Options Locked = The Start and End parameters on the Mode Select Panel are

 

 

 

 

 

locked, all others are unlocked.

 

 

 

 

 

 

• Weld Mode Option Locked = The weld mode cannot be changed from the Mode Select Panel,

 

 

 

 

 

all others Mode Select Panel settings are unlocked.

 

 

 

 

 

 

• Wave Control Options Locked = The Wave Control parameters on the Mode Select Panel are

 

 

 

 

 

locked, all others are unlocked.

 

 

 

 

 

 

• Start, End, Wave Options Locked = The Start, End and Wave Control parameters on the

 

 

 

 

 

Mode Select Panel are locked, all others are unlocked.

 

 

 

 

 

 

• Start, End, Mode Options Locked = The Start, End and Weld Mode Select parameters on the

 

 

 

 

 

Mode Select Panel are locked, all others are unlocked.

 

 

 

 

 

 

This parameter can only be accessed using Power Wave Manager.

 

 

 

 

 

 

 

 

 

 

P.505

Setup Menu Lock

 

 

 

 

 

 

Determines if the setup parameters can be modified by the operator without entering a pass-

 

 

 

 

 

code.

 

 

 

 

 

 

• No = The operator can change any set menu parameter without first entering the passcode

 

 

 

 

 

even if the passcode is non-zero (default).

 

 

 

 

 

 

• Yes = The operator must enter the passcode (if the passcode is non-zero) in order to change

 

 

 

 

 

any setup menu parameters.

 

 

 

 

 

 

This parameter can only be accessed using Power Wave Manager.

 

 

 

 

 

 

 

 

 

 

P.506

Set User Interface Passcode

 

 

 

 

 

 

Prevents unauthorized changes to the equipment. The default passcode is zero which allows

 

 

 

 

 

full access. A nonzero passcode will prevent unauthorized:

 

 

 

 

 

 

• changes to memory limits

 

 

 

 

 

 

• saving to memory (if P.502 = Yes)

 

 

 

 

 

 

• changes to setup parameters (if P.505 = Yes)

 

 

 

 

 

 

This parameter can only be accessed using Power Wave Manager.

 

 

 

 

 

 

 

 

 

POWER FEED™ 25M

Image 47
Contents Power Feed 25M Safety Electric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionPrécautions DE Sûreté On-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Input Voltage ± 10% Input Amperes Gearing WFS Range Wire SizesHeight Width Depth Weight Power Feed 25MElectric Shock can Kill Safety PrecautionsLocation High Frequency ProtectionPIN Arclink Control CablesCable Connections Table A.1 To installWeld Cable Size Coaxial Weld CableBuild UP of Shielding GAS MAY Harm Health or Kill Electrode PolarityShielding GAS Connection OFF Changing the Drive Motor Gear RatioProcedure to Install Drive Rolls and Wire Guides Wire Drive ConfigurationLoading Spools of Wire Remote Sense Lead SpecificationsTypical System Configurations Input Voltage Direct CurrentOpen Circuit VoltageDuty Cycle Definition of Welding TermsEquipment Limitations Recommended Power SourcesRecommended Processes See Figure B.1 Case Front Controls CodeCase Front Controls Code 11456 Definition ON-OFF SwitchStatus LED Table B.1Smaw Stick Welding Making a Weld with Waveform Technology Power SourcesMSP4 Operation Process ModeSmaw Stick Welding Display Three non-synergic welding modes are available NON-SYNERGIC Gmaw and Fcaw WeldingNon-Synergic Gmaw and Fcaw Welding Display MSP4 OperationFigure B.5 Gmaw MIG Synergic WeldingSynergic CV Voltage Display Gmaw MIG Synergic Welding DisplayARC Control Steel and Stainless Synergic GMAW-P Pulsed MIG WeldingSteel and Stainless Synergic GMAW-P Pulsed MIG Welding 220 Figure B.9 Pulse-on-Pulse WeldingAluminum Pulse Welding Aluminum GMAW-P and GMAW-PPFigure B.14 Aluminum GMAW-P and GMAW-PP WeldingWeld Modes Aluminum Pulse and Pulse-On-Pulse Synergic Weld DisplayFigure B.15 GMAW-STT WeldingWeld Modes GMAW-STTTailout Peak Current Figure B.16Background Current Figure B.17 Gtaw TIG Welding Figure B.17a Gtaw Tigwelding Figure B.17aFigure B.17b Setup Menu SET-UP Features MenuUser Defined Parameters Stall Factor Adjustment Parameter Definition Procedure Change MethodTIG Gas Control Parameter Definition Gun Offset AdjustmentCrater Delay Reset Consumable WeightShow Test Modes 100 View DiagnosticsParameter Definition Push-Pull Gun Knob Behavior Sense From Studs105 View Welding Software Information 107 View Power Source ProtocolParameter Definition 103 View Software Version Information 104 View Hardware Version Information506 Set User Interface Passcode Parameter Definition 503 Memory Button Disable504 Mode Select Panel Lock 505 Setup Menu Lock509 UI Master Lockout Parameter Definition 507 UI Clear All MemoriesUser Memories PROCEDURE/MEMORY Panel OPERA- TionMSP4 Display LimitsParameter Range Units Limits may be set forParameter Name High LimitLow Limit For Code 11456 and Higher Dual PROCEDURE/MEMORY OperationMemory Set Limits Memory Value 200Description Internal Controls for CodeEscription Internal Controls for Code 11456 and higherHeater Switch Cold FEED/GAS Purge SwitchLight Switch Pressure ARM AdjustmentCode 11456 and higher Step Trigger OperationSTEP- Trigger Operation Step TriggerWeld PreflowRUN-IN Postflow UpslopeBurnback Crater & Downslope Start & UpslopeCrater Figure B.22 Downslope StartRear Controls DescriptionLiter/Min Operation on Lincnet Power SourcesFlow Meter ScfhDrive Roll Kits Used Factory Installed EquipmentWire Type Electrode Size KP KIT K2593-xx #1 Co-Axial Power Cable K2683-xx Heavy Duty ArcLink Control Cable K1500-5 Gun Receiver Bushing compatible Installation of the K590-6 Water Cooling KIT Water Cooled Guns Calibration Specification Routine MaintenancePeriodic Maintenance Troubleshooting Description Possible Adjustments SymptomsOutput Problems Troubleshooting G5585 Wiring Diagram Power Feed 25MDiagrams Dimensions for Code Dimensions for Codes 11456 Precaucion Warnung