| OPERATION | |||||
|
|
|
|
|
|
|
|
|
|
| USER DEFINED PARAMETERS |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| |
|
| Parameter | Definition |
|
| |
|
|
|
|
|
| |
|
| P.103 | View Software Version Information |
|
| |
|
|
|
| Used for viewing the firmware versions for each board in the system. Press the right MSP |
| |
|
|
|
| Button to enter the option. Rotate Set knob to select the desired board to read. Press the right |
| |
|
|
|
| button again to read the firmware version. Press the left button to back out to select another |
| |
|
|
|
| board. Rotate the SET knob to select another board, or press the left button to exit this option. |
| |
|
|
|
|
|
| |
|
| P.104 | View Hardware Version Information |
|
| |
|
|
|
| Used for viewing the hardware version for each board in the system. Press the right MSP |
| |
|
|
|
| Button to enter the option. Rotate Set knob to select the desired board to read. Press the right |
| |
|
|
|
| button again to read the hardware version. Press the left button to back out to select another |
| |
|
|
|
| board. Press the left button again to exit this option. |
|
|
|
|
|
|
|
| |
|
| P.105 | View Welding Software Information |
|
| |
|
|
|
| Used for viewing the Weld Set in the Power Source. Press the right MSP Button to read the |
| |
|
|
|
| Weld Set version. Press the left button to back out and exit this option. |
|
|
|
|
|
|
|
| |
|
| P.106 | View Ethernet IP Address |
|
| |
|
|
|
| Used for viewing the Ethernet Network IP address if there is an Ethernet board present in the |
| |
|
|
|
| system. Press the right MSP Button to read the IP Address. Press the left button to back out |
| |
|
|
|
| and exit this option. The IP address cannot be changed using this option. |
|
|
|
|
|
|
|
| |
|
| P.107 | View Power Source Protocol |
|
| |
|
|
|
| Used for viewing the type of power source the feeder is connected to. Press the right MSP |
| |
|
|
|
| Button to identify the power source as either LincNet or ArcLink. Press the left button to back |
| |
|
|
|
| out and exit this option. |
|
|
|
|
|
|
|
| |
|
| P.500 | View Lockout Parameters |
|
| |
|
|
|
| Originally used to prevent inadvertent changes of secure setup parameters, P.500 was previ- |
| |
|
|
|
| ously used as a gateway to these parameters. Presently, this option does not exist in any setup |
| |
|
|
|
| menu. |
|
|
|
|
|
|
|
| |
|
| P.501 | Encoder Lockout |
|
| |
|
|
|
| Locks one or both of the upper knobs (encoders), preventing the operator from changing wire |
| |
|
|
|
| feed speed, amps, volts or trim. The function of each upper knob depends on the selected weld |
| |
|
|
|
| mode. When a constant current weld mode is selected (e.g. Stick, TIG, Gouge), the upper right |
| |
|
|
|
| knob will always function as an on/off switch. This parameter can only be accessed using Weld |
| |
|
|
|
| Manager or Power Wave Manager software. |
|
|
|
|
|
|
|
| |
|
| P.502 | Memory Change Lockout |
|
| |
|
|
|
| Determines if the memories can be overwritten with new contents. |
|
|
|
|
|
| • No = Memories can be saved and limits can be configured (default). |
|
|
|
|
|
| • Yes = Memories cannot be changed - saving is prohibited and limits cannot be |
| |
|
|
|
| This parameter can only be accessed using Power Wave Manager. |
|
|
|
|
|
|
|
|
|