Lincoln Electric IM892-C manual Parameter Definition 103 View Software Version Information

Page 46

B-30

 

OPERATION

B-30

 

 

 

 

 

 

 

 

 

 

 

USER DEFINED PARAMETERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Definition

 

 

 

 

 

 

 

 

 

 

P.103

View Software Version Information

 

 

 

 

 

 

Used for viewing the firmware versions for each board in the system. Press the right MSP

 

 

 

 

 

Button to enter the option. Rotate Set knob to select the desired board to read. Press the right

 

 

 

 

 

button again to read the firmware version. Press the left button to back out to select another

 

 

 

 

 

board. Rotate the SET knob to select another board, or press the left button to exit this option.

 

 

 

 

 

 

 

 

 

P.104

View Hardware Version Information

 

 

 

 

 

 

Used for viewing the hardware version for each board in the system. Press the right MSP

 

 

 

 

 

Button to enter the option. Rotate Set knob to select the desired board to read. Press the right

 

 

 

 

 

button again to read the hardware version. Press the left button to back out to select another

 

 

 

 

 

board. Press the left button again to exit this option.

 

 

 

 

 

 

 

 

 

 

P.105

View Welding Software Information

 

 

 

 

 

 

Used for viewing the Weld Set in the Power Source. Press the right MSP Button to read the

 

 

 

 

 

Weld Set version. Press the left button to back out and exit this option.

 

 

 

 

 

 

 

 

 

 

P.106

View Ethernet IP Address

 

 

 

 

 

 

Used for viewing the Ethernet Network IP address if there is an Ethernet board present in the

 

 

 

 

 

system. Press the right MSP Button to read the IP Address. Press the left button to back out

 

 

 

 

 

and exit this option. The IP address cannot be changed using this option.

 

 

 

 

 

 

 

 

 

 

P.107

View Power Source Protocol

 

 

 

 

 

 

Used for viewing the type of power source the feeder is connected to. Press the right MSP

 

 

 

 

 

Button to identify the power source as either LincNet or ArcLink. Press the left button to back

 

 

 

 

 

out and exit this option.

 

 

 

 

 

 

 

 

 

 

P.500

View Lockout Parameters

 

 

 

 

 

 

Originally used to prevent inadvertent changes of secure setup parameters, P.500 was previ-

 

 

 

 

 

ously used as a gateway to these parameters. Presently, this option does not exist in any setup

 

 

 

 

 

menu.

 

 

 

 

 

 

 

 

 

 

P.501

Encoder Lockout

 

 

 

 

 

 

Locks one or both of the upper knobs (encoders), preventing the operator from changing wire

 

 

 

 

 

feed speed, amps, volts or trim. The function of each upper knob depends on the selected weld

 

 

 

 

 

mode. When a constant current weld mode is selected (e.g. Stick, TIG, Gouge), the upper right

 

 

 

 

 

knob will always function as an on/off switch. This parameter can only be accessed using Weld

 

 

 

 

 

Manager or Power Wave Manager software.

 

 

 

 

 

 

 

 

 

 

P.502

Memory Change Lockout

 

 

 

 

 

 

Determines if the memories can be overwritten with new contents.

 

 

 

 

 

 

• No = Memories can be saved and limits can be configured (default).

 

 

 

 

 

 

• Yes = Memories cannot be changed - saving is prohibited and limits cannot be re-configured.

 

 

 

 

 

This parameter can only be accessed using Power Wave Manager.

 

 

 

 

 

 

 

 

 

POWER FEED™ 25M

Image 46
Contents Power Feed 25M Safety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Please Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Power Feed 25M Gearing WFS Range Wire SizesHeight Width Depth Weight Input Voltage ± 10% Input AmperesHigh Frequency Protection Safety PrecautionsLocation Electric Shock can KillCable Connections Arclink Control CablesPIN Coaxial Weld Cable To installWeld Cable Size Table A.1Shielding GAS Connection Electrode PolarityBuild UP of Shielding GAS MAY Harm Health or Kill Changing the Drive Motor Gear Ratio OFFWire Drive Configuration Procedure to Install Drive Rolls and Wire GuidesRemote Sense Lead Specifications Loading Spools of WireTypical System Configurations Voltage Direct CurrentOpen Circuit Input VoltageDefinition of Welding Terms Duty CycleRecommended Processes Recommended Power SourcesEquipment Limitations Case Front Controls Code See Figure B.1Case Front Controls Code 11456 Table B.1 ON-OFF SwitchStatus LED DefinitionMaking a Weld with Waveform Technology Power Sources Smaw Stick WeldingSmaw Stick Welding Display Process ModeMSP4 Operation NON-SYNERGIC Gmaw and Fcaw Welding Three non-synergic welding modes are availableMSP4 Operation Non-Synergic Gmaw and Fcaw Welding DisplayGmaw MIG Synergic Welding Figure B.5Gmaw MIG Synergic Welding Display Synergic CV Voltage DisplaySteel and Stainless Synergic GMAW-P Pulsed MIG Welding ARC ControlSteel and Stainless Synergic GMAW-P Pulsed MIG Welding 220 Pulse-on-Pulse Welding Figure B.9Aluminum GMAW-P and GMAW-PP Aluminum Pulse WeldingAluminum GMAW-P and GMAW-PP Welding Figure B.14Aluminum Pulse and Pulse-On-Pulse Synergic Weld Display Weld ModesGMAW-STT Welding Figure B.15GMAW-STT Weld ModesBackground Current Figure B.17 Peak Current Figure B.16Tailout Gtaw TIG Welding Gtaw Tigwelding Figure B.17a Figure B.17aSET-UP Features Menu Figure B.17b Setup MenuUser Defined Parameters Parameter Definition Procedure Change Method Stall Factor AdjustmentReset Consumable Weight Parameter Definition Gun Offset AdjustmentCrater Delay TIG Gas ControlSense From Studs 100 View DiagnosticsParameter Definition Push-Pull Gun Knob Behavior Show Test Modes104 View Hardware Version Information 107 View Power Source ProtocolParameter Definition 103 View Software Version Information 105 View Welding Software Information505 Setup Menu Lock Parameter Definition 503 Memory Button Disable504 Mode Select Panel Lock 506 Set User Interface PasscodeParameter Definition 507 UI Clear All Memories 509 UI Master LockoutPROCEDURE/MEMORY Panel OPERA- Tion User MemoriesLimits may be set for LimitsParameter Range Units MSP4 DisplayLow Limit High LimitParameter Name Dual PROCEDURE/MEMORY Operation For Code 11456 and HigherMemory Set Limits 200 Memory ValueInternal Controls for Code DescriptionInternal Controls for Code 11456 and higher EscriptionPressure ARM Adjustment Cold FEED/GAS Purge SwitchLight Switch Heater SwitchStep Trigger Step Trigger OperationSTEP- Trigger Operation Code 11456 and higherRUN-IN PreflowWeld Burnback UpslopePostflow Crater Start & UpslopeCrater & Downslope Figure B.22 Start DownslopeDescription Rear ControlsScfh Operation on Lincnet Power SourcesFlow Meter Liter/MinWire Type Electrode Size KP KIT Factory Installed EquipmentDrive Roll Kits Used K2593-xx #1 Co-Axial Power Cable K2683-xx Heavy Duty ArcLink Control Cable K1500-5 Gun Receiver Bushing compatible Installation of the K590-6 Water Cooling KIT Water Cooled Guns Periodic Maintenance Routine MaintenanceCalibration Specification Troubleshooting Symptoms Description Possible AdjustmentsOutput Problems Troubleshooting Wiring Diagram Power Feed 25M G5585Diagrams Dimensions for Code Dimensions for Codes 11456 Precaucion Warnung