Lincoln Electric IM892-C manual Electrode Polarity, Shielding GAS Connection

Page 12

A-5

INSTALLATION

A-5

 

 

 

ELECTRODE POLARITY

The wire feeder is factory set for Electrode Positive welding. Most GMAW welding procedures use Electrode Positive welding. Most GTAW and some Innershield procedures use Electrode Negative weld- ing.

CAUTION

When changing the electrode polarity, the weld cables must be changed at the power source studs and the DIP switch inside the wire feeder must be properly set. Operation with the DIP switch in the wrong position will cause erratic arc performance.

WARNING

ELECTRIC SHOCK CAN KILL.

Turn the input power OFF at the weld- ing power source before changing electrode polarity.

Do not touch electrically live parts.

Only qualified personnel should per-

form maintenance work.

------------------------------------------------------------------------

Electrode Polarity

DIP switch #7 setting

Positive

OFF (Factory setting)

Negative

ON

Tools required:

• 5/16" nut driver

To change the DIP switch from Electrode Polarity:

1.Turn power off at the welding power source

2.Remove the spool of wire from the feeder.

3.Remove the 4 screws holding the cover. Lift the cover out of the feeder.

4.Move DIP switch #7 on the feed head board to the appropriate position.

5.Install the cover and secure with the screws.

SHIELDING GAS CONNECTION

WARNING

CYLINDER may explode if damaged.

• Keep cylinder upright and chained to support.

Keep cylinder away from areas where it may be damaged.

Never lift welder with cylinder attached.

Never allow welding electrode to touch cylinder.

Keep cylinder away from welding or other live electrical circuits.

BUILD UP OF SHIELDING GAS MAY HARM HEALTH OR KILL.

• Shut off shielding gas supply when not in use.

See American National Standard Z-49.1, "Safety in Welding and Cutting” Published by the American Welding Society.

------------------------------------------------------------------------

MAXIMUM INLET PRESSURE IS 100 PSI. (6.9 BAR.)

Install the shielding gas supply as follows:

1.Secure the cylinder to prevent it from falling.

2.Remove the cylinder cap. Inspect the cylinder valves and regulator for damaged threads, dirt, dust, oil or grease. Remove dust and dirt with a clean cloth. DO

NOT ATTACH THE REGULATOR IF OIL, GREASE OR DAMAGE IS PRESENT! Inform your gas supplier of this condition. Oil or grease in the presence of high pressure oxygen is explosive.

3.Stand to one side away from the outlet and open the cylinder valve for an instant. This blows away any dust or dirt which may have accumulated in the valve out- let.

4.Attach the flow regulator to the cylinder valve and tighten the union nut(s) securely with a wrench. Note:

if connecting to 100% CO2 cylinder, insert regulator adapter between regulator and cylinder valve. If adapter is equipped with a plastic washer, be sure it is seated for connection to the CO2 cylinder.

5.Attach one end of the inlet hose to the outlet fitting of the flow regulator. Attach the other end to the welding system shielding gas inlet. Tighten the union nuts with a wrench.

6.Before opening the cylinder valve, turn the regulator adjusting knob counterclockwise until the adjusting spring pressure is released.

7.Standing to one side, open the cylinder valve slowly a fraction of a turn. When the cylinder pressure gage stops moving, open the valve fully.

8.The flow regulator is adjustable. Adjust it to the flow rate recommended for the procedure and process being used before making a weld.

POWER FEED™ 25M

Image 12
Contents Power Feed 25M Safety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Please Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Gearing WFS Range Wire Sizes Height Width Depth WeightPower Feed 25M Input Voltage ± 10% Input AmperesSafety Precautions LocationHigh Frequency Protection Electric Shock can KillArclink Control Cables Cable ConnectionsPIN To install Weld Cable SizeCoaxial Weld Cable Table A.1Electrode Polarity Shielding GAS ConnectionBuild UP of Shielding GAS MAY Harm Health or Kill Changing the Drive Motor Gear Ratio OFFWire Drive Configuration Procedure to Install Drive Rolls and Wire GuidesRemote Sense Lead Specifications Loading Spools of WireTypical System Configurations Direct Current Open CircuitVoltage Input VoltageDefinition of Welding Terms Duty CycleRecommended Power Sources Recommended ProcessesEquipment Limitations Case Front Controls Code See Figure B.1Case Front Controls Code 11456 ON-OFF Switch Status LEDTable B.1 DefinitionMaking a Weld with Waveform Technology Power Sources Smaw Stick WeldingProcess Mode Smaw Stick Welding DisplayMSP4 Operation NON-SYNERGIC Gmaw and Fcaw Welding Three non-synergic welding modes are availableMSP4 Operation Non-Synergic Gmaw and Fcaw Welding DisplayGmaw MIG Synergic Welding Figure B.5Gmaw MIG Synergic Welding Display Synergic CV Voltage DisplaySteel and Stainless Synergic GMAW-P Pulsed MIG Welding ARC ControlSteel and Stainless Synergic GMAW-P Pulsed MIG Welding 220 Pulse-on-Pulse Welding Figure B.9Aluminum GMAW-P and GMAW-PP Aluminum Pulse WeldingAluminum GMAW-P and GMAW-PP Welding Figure B.14Aluminum Pulse and Pulse-On-Pulse Synergic Weld Display Weld ModesGMAW-STT Welding Figure B.15GMAW-STT Weld ModesPeak Current Figure B.16 Background Current Figure B.17Tailout Gtaw TIG Welding Gtaw Tigwelding Figure B.17a Figure B.17aSET-UP Features Menu Figure B.17b Setup MenuUser Defined Parameters Parameter Definition Procedure Change Method Stall Factor AdjustmentParameter Definition Gun Offset Adjustment Crater DelayReset Consumable Weight TIG Gas Control100 View Diagnostics Parameter Definition Push-Pull Gun Knob BehaviorSense From Studs Show Test Modes107 View Power Source Protocol Parameter Definition 103 View Software Version Information104 View Hardware Version Information 105 View Welding Software InformationParameter Definition 503 Memory Button Disable 504 Mode Select Panel Lock505 Setup Menu Lock 506 Set User Interface PasscodeParameter Definition 507 UI Clear All Memories 509 UI Master LockoutPROCEDURE/MEMORY Panel OPERA- Tion User MemoriesLimits Parameter Range UnitsLimits may be set for MSP4 DisplayHigh Limit Low LimitParameter Name Dual PROCEDURE/MEMORY Operation For Code 11456 and HigherMemory Set Limits 200 Memory ValueInternal Controls for Code DescriptionInternal Controls for Code 11456 and higher EscriptionCold FEED/GAS Purge Switch Light SwitchPressure ARM Adjustment Heater SwitchStep Trigger Operation STEP- Trigger OperationStep Trigger Code 11456 and higherPreflow RUN-INWeld Upslope BurnbackPostflow Start & Upslope CraterCrater & Downslope Figure B.22 Start DownslopeDescription Rear ControlsOperation on Lincnet Power Sources Flow MeterScfh Liter/MinFactory Installed Equipment Wire Type Electrode Size KP KITDrive Roll Kits Used K2593-xx #1 Co-Axial Power Cable K2683-xx Heavy Duty ArcLink Control Cable K1500-5 Gun Receiver Bushing compatible Installation of the K590-6 Water Cooling KIT Water Cooled Guns Routine Maintenance Periodic MaintenanceCalibration Specification Troubleshooting Symptoms Description Possible AdjustmentsOutput Problems Troubleshooting Wiring Diagram Power Feed 25M G5585Diagrams Dimensions for Code Dimensions for Codes 11456 Precaucion Warnung