INSTALLATION | ||
|
|
|
ELECTRODE POLARITY
The wire feeder is factory set for Electrode Positive welding. Most GMAW welding procedures use Electrode Positive welding. Most GTAW and some Innershield procedures use Electrode Negative weld- ing.
CAUTION
When changing the electrode polarity, the weld cables must be changed at the power source studs and the DIP switch inside the wire feeder must be properly set. Operation with the DIP switch in the wrong position will cause erratic arc performance.
WARNING
ELECTRIC SHOCK CAN KILL.
•Turn the input power OFF at the weld- ing power source before changing electrode polarity.
•Do not touch electrically live parts.
•Only qualified personnel should per-
form maintenance work.
Electrode Polarity | DIP switch #7 setting |
Positive | OFF (Factory setting) |
Negative | ON |
Tools required:
• 5/16" nut driver
To change the DIP switch from Electrode Polarity:
1.Turn power off at the welding power source
2.Remove the spool of wire from the feeder.
3.Remove the 4 screws holding the cover. Lift the cover out of the feeder.
4.Move DIP switch #7 on the feed head board to the appropriate position.
5.Install the cover and secure with the screws.
SHIELDING GAS CONNECTION
WARNING
CYLINDER may explode if damaged.
• Keep cylinder upright and chained to support.
•Keep cylinder away from areas where it may be damaged.
•Never lift welder with cylinder attached.
•Never allow welding electrode to touch cylinder.
•Keep cylinder away from welding or other live electrical circuits.
•BUILD UP OF SHIELDING GAS MAY HARM HEALTH OR KILL.
• Shut off shielding gas supply when not in use.
•See American National Standard
MAXIMUM INLET PRESSURE IS 100 PSI. (6.9 BAR.)
Install the shielding gas supply as follows:
1.Secure the cylinder to prevent it from falling.
2.Remove the cylinder cap. Inspect the cylinder valves and regulator for damaged threads, dirt, dust, oil or grease. Remove dust and dirt with a clean cloth. DO
NOT ATTACH THE REGULATOR IF OIL, GREASE OR DAMAGE IS PRESENT! Inform your gas supplier of this condition. Oil or grease in the presence of high pressure oxygen is explosive.
3.Stand to one side away from the outlet and open the cylinder valve for an instant. This blows away any dust or dirt which may have accumulated in the valve out- let.
4.Attach the flow regulator to the cylinder valve and tighten the union nut(s) securely with a wrench. Note:
if connecting to 100% CO2 cylinder, insert regulator adapter between regulator and cylinder valve. If adapter is equipped with a plastic washer, be sure it is seated for connection to the CO2 cylinder.
5.Attach one end of the inlet hose to the outlet fitting of the flow regulator. Attach the other end to the welding system shielding gas inlet. Tighten the union nuts with a wrench.
6.Before opening the cylinder valve, turn the regulator adjusting knob counterclockwise until the adjusting spring pressure is released.
7.Standing to one side, open the cylinder valve slowly a fraction of a turn. When the cylinder pressure gage stops moving, open the valve fully.
8.The flow regulator is adjustable. Adjust it to the flow rate recommended for the procedure and process being used before making a weld.