Lincoln Electric IM892-C manual High Limit, Low Limit, Parameter Name

Page 51

B-35

OPERATION

B-35

 

 

 

If the passcode does not equal zero (0000), enter the passcode now. If the passcode has been forgotten, a p.c. computer application or Palm O.S. application is required to change the passcode

Memory Value

 

High Limit

 

Low Limit

 

 

 

WAVEFORM CONTROL TECHNOLOGY

IR PORT

200Lo ==

180200

 

Hi

 

 

 

SETUP

 

Weld WFS

WELD MODE

 

START OPTIONS

ARC CONTROL

 

END OPTIONS

SET

Parameter Name

If the passcode has been set to zero (0000), SETUP will illuminate on the MSP4 panel and the display will show the following:

Four items show on the MSP4 panel.

Memory Value

High Limit

Low Limit

Parameter Name

One of these items will flash to indicate which item will change when the MSP4 encoder is rotated. Press the right button on the MSP4 panel to select the item to change.

The Limits Setup menu shows a list of all parameters available for the weld mode stored in the memory cho- sen. For example, if limits are being set for a stick (SMAW) mode, parameters such as Run-in WFS and Postflow will not appear.

To lock a parameter to a specific value that cannot be changed, set the high and low limits to the same value.

 

WAVEFORM CONTROL TECHNOLOGY

IR PORT

200Lo ==

180200

 

Hi

 

 

 

SETUP

 

Weld WFS

WELD MODE

 

START OPTIONS

ARC CONTROL

 

END OPTIONS

 

SET

 

 

Rotate to

Press to

 

Change

select item

 

Value.

to change.

The memory value must always be less than or equal to the high limit, and greater than or equal to the low limit.

After setting limits, press the memory button with the flashing LED. The MSP4 will ask to save or discard the limit changes just made. Press the left MSP4 for button (YES) to save and enable the limits and exit. Press the right MSP4 button (NO) to exit and leave limits unchanged.

Enabling/Disabling Limits

Enable/Disable

Limits: Press

10 seconds

MMEMORYM

PROCEDURE

A GUN B

1 2 3

HOLD 2 SECONDS TO SAVE

4 5 6

Limits for each memory may be enabled or disabled by pressing and hold the appropriate memory button for 10 seconds. Release the memory button when the MSP4 display shows the following:

 

WAVEFORM CONTROL TECHNOLOGY

 

Memory 1

IR PORT

Limits

 

SETUP

 

Enable/Disable

WELD MODE

START OPTIONS

ARC CONTROL

END OPTIONS

 

SET

If the passcode does not equal zero, enter the passcode now. If the passcode is zero (0000), SETUP will light and the MSP4 displays the following:

WAVEFORM CONTROL TECHNOLOGY

 

Enable

IR PORT

Limits?

 

SETUP

Yes

No

WELD MODE

START OPTIONS

ARC CONTROL

END OPTIONS

 

SET

Press the left MSP4 button (YES) to enable limits or the right MSP4 button (NO) to disable limits. Disabling limits does not change any limits values that may have been previously set.

POWER FEED™ 25M

Image 51
Contents Power Feed 25M Safety Electric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionPrécautions DE Sûreté On-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Input Voltage ± 10% Input Amperes Gearing WFS Range Wire SizesHeight Width Depth Weight Power Feed 25MElectric Shock can Kill Safety PrecautionsLocation High Frequency ProtectionArclink Control Cables Cable ConnectionsPIN Table A.1 To installWeld Cable Size Coaxial Weld CableElectrode Polarity Shielding GAS ConnectionBuild UP of Shielding GAS MAY Harm Health or Kill OFF Changing the Drive Motor Gear RatioProcedure to Install Drive Rolls and Wire Guides Wire Drive ConfigurationLoading Spools of Wire Remote Sense Lead SpecificationsTypical System Configurations Input Voltage Direct CurrentOpen Circuit VoltageDuty Cycle Definition of Welding TermsRecommended Power Sources Recommended ProcessesEquipment Limitations See Figure B.1 Case Front Controls CodeCase Front Controls Code 11456 Definition ON-OFF SwitchStatus LED Table B.1Smaw Stick Welding Making a Weld with Waveform Technology Power SourcesProcess Mode Smaw Stick Welding DisplayMSP4 Operation Three non-synergic welding modes are available NON-SYNERGIC Gmaw and Fcaw WeldingNon-Synergic Gmaw and Fcaw Welding Display MSP4 OperationFigure B.5 Gmaw MIG Synergic WeldingSynergic CV Voltage Display Gmaw MIG Synergic Welding DisplayARC Control Steel and Stainless Synergic GMAW-P Pulsed MIG WeldingSteel and Stainless Synergic GMAW-P Pulsed MIG Welding 220 Figure B.9 Pulse-on-Pulse WeldingAluminum Pulse Welding Aluminum GMAW-P and GMAW-PPFigure B.14 Aluminum GMAW-P and GMAW-PP WeldingWeld Modes Aluminum Pulse and Pulse-On-Pulse Synergic Weld DisplayFigure B.15 GMAW-STT WeldingWeld Modes GMAW-STTPeak Current Figure B.16 Background Current Figure B.17Tailout Gtaw TIG Welding Figure B.17a Gtaw Tigwelding Figure B.17aFigure B.17b Setup Menu SET-UP Features MenuUser Defined Parameters Stall Factor Adjustment Parameter Definition Procedure Change MethodTIG Gas Control Parameter Definition Gun Offset AdjustmentCrater Delay Reset Consumable WeightShow Test Modes 100 View DiagnosticsParameter Definition Push-Pull Gun Knob Behavior Sense From Studs105 View Welding Software Information 107 View Power Source ProtocolParameter Definition 103 View Software Version Information 104 View Hardware Version Information506 Set User Interface Passcode Parameter Definition 503 Memory Button Disable504 Mode Select Panel Lock 505 Setup Menu Lock509 UI Master Lockout Parameter Definition 507 UI Clear All MemoriesUser Memories PROCEDURE/MEMORY Panel OPERA- TionMSP4 Display LimitsParameter Range Units Limits may be set forHigh Limit Low LimitParameter Name For Code 11456 and Higher Dual PROCEDURE/MEMORY OperationMemory Set Limits Memory Value 200Description Internal Controls for CodeEscription Internal Controls for Code 11456 and higherHeater Switch Cold FEED/GAS Purge SwitchLight Switch Pressure ARM AdjustmentCode 11456 and higher Step Trigger OperationSTEP- Trigger Operation Step TriggerPreflow RUN-INWeld Upslope BurnbackPostflow Start & Upslope CraterCrater & Downslope Figure B.22 Downslope StartRear Controls DescriptionLiter/Min Operation on Lincnet Power SourcesFlow Meter ScfhFactory Installed Equipment Wire Type Electrode Size KP KITDrive Roll Kits Used K2593-xx #1 Co-Axial Power Cable K2683-xx Heavy Duty ArcLink Control Cable K1500-5 Gun Receiver Bushing compatible Installation of the K590-6 Water Cooling KIT Water Cooled Guns Routine Maintenance Periodic MaintenanceCalibration Specification Troubleshooting Description Possible Adjustments SymptomsOutput Problems Troubleshooting G5585 Wiring Diagram Power Feed 25MDiagrams Dimensions for Code Dimensions for Codes 11456 Precaucion Warnung