| SPECIFICATIONS |
| ||||
|
|
|
|
|
|
|
| |
TECHNICAL SPECIFICATIONS - POWER WAVE® AC/DC 1000 | ||||||||
|
|
|
|
|
|
|
| |
|
| INPUT AT RATED OUTPUT - THREE PHASE ONLY |
| |||||
INPUT VOLTS | INPUT | OUTPUT | IDLE | POWER FACTOR | EFFICIENCY | |||
3 PHASE | CURRENT | AMPS | CONDITIONS | |||||
POWER | @ RATED OUTPUT | @ RATED OUTPUT | ||||||
50/60 Hz |
| WATTS |
|
| ||||
380 | 82 |
|
|
|
| |||
400 | 79 | 1000A@44V. |
|
|
| |||
460 | 68 | 69 | 100% Duty Cycle | 225 | .95 | 86% | ||
500 | 62 | 62 |
|
|
|
| ||
575 | 54 | 55 |
|
|
|
| ||
|
|
|
|
|
|
|
|
OUTPUT
OPEN | AUXILIARY | POWER |
| PROCESS CURRENT RANGES (AC or DC) | ||||||||
CIRCUIT |
| (CIRCUIT BREAKER |
|
|
|
|
|
|
|
| ||
VOLTAGE |
| PROTECTED) |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |||||
25 to 100 |
| 40 VDC AT |
| } |
| Output Range | ||||||
VRMS |
| 10 AMPS |
|
| ||||||||
|
| 115 VAC AT |
|
|
|
|
| |||||
|
| 10 AMPS |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||||||
|
| RECOMMENDED INPUT WIRE AND FUSE SIZES1 |
| |||||||||
3 PHASE INPUT |
| TYPE 90°C |
| COPPER GROUNDING | ||||||||
VOLTAGE 50/60Hz |
| COPPER WIRE3 IN |
| CONDUCTOR | OR BREAKER2 | |||||||
|
|
|
| CONDUIT |
|
|
|
|
|
|
| |
|
|
|
| AWG (mm2) |
|
|
| AWG (mm2) |
| AMPS | ||
| 380 |
|
| 3(25) |
|
|
| 8 (10) |
| 100 | ||
| 400 |
|
| 3(25) |
|
|
| 8 (10) |
| 90 | ||
| 460 |
|
| 4(25) |
|
|
| 8 (10) |
| 90 | ||
| 500 |
|
| 4(25) |
|
|
| 8 (10) |
| 80 | ||
| 575 |
|
| 6(16) |
|
|
| 10 (6) |
| 70 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
PHYSICAL DIMENSIONS
MODEL |
| CONFORMITY MARK |
| HEIGHT | WIDTH | DEPTH |
| WEIGHT | |||
|
|
| CSA C/UL |
| 43.5 in | 19.2 in | 33 in |
| 600 lbs. | ||
|
|
|
| 1105 mm | 488 mm | 838 mm |
| 272 kg. | |||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
* |
|
| EN |
| 43.5 in | 19.2 in | 33 in |
| 650 lbs. | ||
|
| CSA C/UL |
| 1105 mm | 488 mm | 838 mm |
| 296 kg. | |||
|
|
|
|
|
| ||||||
|
|
|
|
| TEMPERATURE RANGES |
|
|
| |||
OPERATING TEMPERATURE RANGE |
| STORAGE TEMPERATURE RANGE | |||||||||
|
| 32°F to 104°F(0°C to 40°C) |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
Insulation Class: Class F(155°C)
1Wire and Fuse Sizes based upon the U.S. National Electric Code and maximum output for 40°C (104°) ambient.
2Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers that have a delay in tripping action that decreases as the magnitude of current increases.
3Fail to use proper type of copper wire will cause fire hazards.
*An external filter will be required to meet CE and
WELDING PROCESSES
Process
Electrode Diameter Range Output Range (Amperes
Wire Feed Speed Range
SAW
5/64 – 7/32" (2 – 5.6 mm)
200 - 1000
21 - 300 ipm (.53 – 7.62 m/minute)
POWER WAVE® AC/DC 1000