Lincoln Electric 11124, 11226 manual Phase, Recommendations

Page 49

B-11

OPERATION

B-11

 

 

 

MULTIPLE ARC AC ADJUSTMENTS FOR

SYSTEMS EQUIPPED WITH K2282-1

SYSTEM INTERFACE

Phase

The phase relationship between the arcs helps to minimize the magnetic interaction between adjacent arcs. It is essentially a time offset between the wave- forms of different arcs, and is set in terms of an angle from 0 to 360°, representing no offset to a full period offset. The offset of each arc is set independently with respect to the lead arc of the system (ARC 1).

Recommendations:

For balanced waveforms a phase relationship of 90° should be maintained between adjacent arcs.

 

ARC 1

ARC2

ARC3

ARC 4

2 Arc System

90°

X

X

3 Arc System

90°

180°

X

4 Arc System

90°

180°

270°

 

 

 

 

 

For unbalanced waveforms:

Avoid switching at same time

Break up long periods of unchanged polarity relative to adjacent arcs

Phase Relationship

Use Phase Relation ship to minimize arc blow

 

in multip le arc systems.

 

 

(Balanced two arc system shown)

 

90°

180°

(PULL)

(PUSH/PULL)

(PUSH)

500

 

 

ARC 1

 

 

ARC 2

 

 

0

 

 

-500

 

 

BAD

GOOD

BAD

Best results obtained by alternating and equalizing the duration of

magnetic forces between adjacent arcs.

POWER WAVE® AC/DC 1000

Image 49
Contents Power Wave AC/DC Mar ‘95 SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéSafety Safety Thank You Table of Contents Table of Contents Specifications Installation Input and Ground Connections Input Fuse and Supply Wire ConsiderationsInput Connection Input Voltage SelectionSystem Overview System ConnectionSystem Description Single Arc Tandem Arc Triple Arc 3,4 Recommended EquipmentSystem Identifier Description Optional EquipmentElectrode Studs Work Studs Arclink 5 Pin Step by Step Installation Checklist Wire Reel Mountings Step by Step Installation Checklist System DeviceNet PLC Controller Installation Connection Diagram- Parallel Machines PF-10A Controlled Systems PF-10S ConnectionsDeviceNet PLC Controlled Systems Connections Electrode and WorkCable INDUCTANCE, and ITS Effects on Welding Remove the front cover from the power sourceRemote Sense Lead Connections Voltage Sensing OverviewVoltage Sensing Considerations for Multiple ARC Systems Voltage Sensing for Slave machinesPower Common Equipment Connections Control Cable ConnectionsInstallation Receptacle Specification External I/O ConnectorTable A.4 RS232 Connector S3 DB-25 style Table A.5 DeviceNet Connector S5 5 pin mini styleTransmit + Table A.7 External I/O S7 12 pin terminal blockTransmit Receive +Ethernet Configuration Wire Drive Gear Ratio SettingInternal Controls Devicenet ConfigurationInternal Controls Description Feed Head Board DIP Switch S1 Control Board DIP Switch S1Ethernet Board DIP Switches S1, S2 Object Instance Off 0defaultTable A.14 Table A.15Devicenet MAC ID Table A.16 Master Master / Slave ConfigSlave Bank S4 Bank S3Definitions of Welding Modes OperationCommon Welding Abbreviations Input Power Three Phase Positive Output Negative Output Phase InverterProtective GroundRecommended Processes Product SummaryProcess Limitations Equipment LimitationsSee Figure B.4 Case Front Control DescriptionsFigure B.5 Power Wave AC/DC Case Rear Components POWER-UP SequenceDuty Cycle Common Welding ProceduresOverview of the AC/DC Submerged ARC Process Making a WeldBasic Modes of Operation Multiple ARC System ConsiderationsConstant Current CC Constant Voltage CVWeld Sequence RE-STRIKE TimerStart Options END OptionsAC Adjustments Weld Process Adjustments DC OffsetWave Balance FrequencyRecommendations PhaseKITS, Options and Accessories AccessoriesOptional Kits and Accessories Software ToolsPeriodic Maintenance MaintenanceCalibration Specification HOW to USE Troubleshooting Guide TroubleshootingRecommended SymptomsCourse of Action Qualified person should Perform this operationRecommended Symptoms ARC Quality Problems Weld Tab of the Diagnostics Utility Diagnostics Utility displays Diagnostics Utility, select MonitorDiagnostics Utility, select Changed, select Configure, Power Wave’s passive modeProduced Assembly that Gas Analog In Active Selections From the DeviceNet tabScans Between Updates and I/O Bad Weld Ending Burnback DisabledBetween Updates is 1/4 of I/O Bad Welding Analog Scans Between UpdatesManager utility Utility included on the Power Wave Submerged Arc Present. Read the error codes before the machineUtilities and Service Navigator CD’s. This is the pre Is turned offError Codes Power SOURCE- Weld ControllerError Code # Indication This error will immediately turn off the machine outputWire Drive Module 1000 DiagramsDiagrams AC Switch Wiring Diagram AC Switch Wiring Diagram Dimension Print Power Wave AC/DC Precaucion Warnung