SM 1619X03291
Battery Disposal
Do not attempt to disas- ! WARNING semble the battery or remove any component projecting from the battery terminals. Fire or injury may result. Prior to disposal, protect exposed terminals with heavy
insulating tape to prevent shorting.
LITHIUM-ION BATTERIES
If equipped with a
“The EPA certified RBRC Battery Recycling Seal on the
program to collect and recycle these batteries at the end of their useful life, when taken out of service in the United States or Canada. The RBRC program provides a convenient alterative to placing used
Please call
Battery Disposal – 2362
BATTERY REMOVAL INSTRUCTIONS
!Run motor until battery is CAUTION completely discharged before
attempting to remove battery from your tool.
1.Remove the seven (7) housing screws with a flat blade screwdriver.
2.Remove housing cover by lifting upward from front end of tool.
3.Disconnect lead wires from switch.
4.Wrap heavy insulating tape around battery terminals or enclose in a sealable plastic bag to prevent possible shorting.
5.Dispose of battery through your local waste removal authority or a Skil Service Center.
Battery Disposal – 2372
BATTERY REMOVAL INSTRUCTIONS
!Run motor until battery is CAUTION completely discharged before
attempting to remove battery from your tool.
1.Loosen the nut with a large wrench in direction of arrow (A) and completely unthread nut.
2.Remove head assembly and nut from the tool.
3.Pull and remove metal front end in direction of arrow (B) to expose and remove the two T6 torx head screws.
4.Remove the six (6) housing screws with a flat blade screwdriver.
5.Remove housing cover by lifting upward from front end of tool.
6.Remove lead wires from switch.
7.Wrap heavy insulating tape around battery
terminals or enclose in a sealable plastic bag to prevent possible shorting.
8.Dispose of battery through your local waste removal authority or a Skil Service Center.
FIG. 2
HEAD ASSEMBLY
ARROW (A)
NUT
METAL FRONT END
ARROW (B)
T6 TORX HEAD
SCREW