3M #3968, #3960 manual 3M Rapid Detection Reader Modules, Turning on the 3M Rapid Detection Reader

Page 13

3M™ Rapid Detection Reader

3M Rapid Detection Reader (MODULES)

3M Rapid Detection Reader (MODULES)

Figure 2. 3M Rapid Detection Reader Features - Front View

Control Module

Touch

 

Screen

 

Display

 

Lot Card

 

Insertion Slot

Test Module (3 max)

Port LEDs

 

 

Test Cartridge

 

Ports

Turning on the 3M Rapid Detection Reader

 

The power On/Off switch is located on the rear panel of the CM

Figure 3. Home

(Figure 1). When the power is switched on, the 3M Rapid Detection

 

 

Reader performs a number of internal self-tests, including IQC, to

 

ensure the system is operating within specifications. For additional

 

information, refer to Running Quality Control section.

 

When switched ON, the LEDs on the front of the TM illuminate blue.

 

When the power-on sequence is complete, the Home screen is

 

displayed (Figure 3). The power-on sequence takes approximately

 

1 minute.

 

Once the Home screen is displayed, selections can be made by

 

touching the appropriate prompt on the display (i.e., Run Assay to

 

initiate an assay, or Menu to go to the Main Menu screen (Figure 4)).

 

The display is touch-sensitive and can accept input from a bare/gloved

 

finger or a blunt stylus.

 

The 3M Rapid Detection Reader can be operated immediately after

 

set-up using the pre-programmed default settings. The date, local

 

time and some settings can be edited manually through the Settings

 

menu on the CM touch screen. Most settings can be edited using the

 

Reader Configuration Utility (RCU) supplied with the CM. For

 

additional information on editing user settings, refer to Managing

 

Settings and Editing Settings Using the Reader Configuration Utility

 

(RCU).

 

CAUTION.

Pens or other sharp instruments will damage the touch screen.

8

Image 13
Contents Operator Manual Made in Canada for Table of Contents Maintenance Iii Consult Accompanying Documents Consult Operator Manual Read all contents of this manual prior to useTo reduce the risk of instrument or accessory damage Summary of Warnings and PrecautionsTo reduce the risk associated with hazardous voltage To reduce the risk associated with incorrect resultsOverview IntroductionIntended Use Optional Accessories Available from 3M Unpacking and Setup3M Rapid Detection Reader Components To set-up 3M Rapid Detection Reader 3M Rapid Detection Reader SetupBarcode Scanner § 3M Rapid Detection Control Module CM3M Rapid Detection Reader 3M Rapid Detection Test Module CM Port 3M Rapid Detection Control Module3M Rapid Detection Reader Modules Reader Configuration Utility RCU supplied with the CM. ForTurning on the 3M Rapid Detection Reader Port Identification Nomenclature Display IconsPerforming an Assay Using Lot CardsStarting an Assay Operator Entry Accept Running Quality ControlAssay Status Warnings LQC IconsTo run IQC manually Running IQCTo run IQC automatically Viewing Saved Results Working with Results and LogsViewing Saved Logs Searching Logs Searching ResultsResults Transfer Manually Transferring / Printing Results or LogsLQC Managing SettingsAssay Settings View TabsTimer Printer LoginNetwork Settings Login RequirementsFile Privilege RequirementsAbout Settings View About TabSettings Edit Tabs Edit SettingsTimers Date/Time Manual / Auto Transfer ModeLanguage MiscManaging Operators Restoring DefaultsSound To Add an Operator Adding/Modifying an OperatorSearching for an Individual Operator Touch Search or CancelTo Modify an Operator Installation Editing Settings Using the Reader Configuration Utility RCULogin Getting StartedChoosing a Configuration File Access Method Emergency Password Reset MechanismSetting Up a USB Flash Drive Setting Up Web Services AccessTo open all files for a group Accessing Configuration FilesTo open an Individual Configuration File Setting Up Communications Between RCU and ReadersFiles Non-networked Environment Identifying Readers through the RCUNetworked Environment Touch Export to USB Flash DriveExporting Files Importing FilesDelete Results Prior to Date Deleting ResultsExterior Cleaning MaintenancePossible device damage Disposal of Equipment Upgrading Device SoftwareRestoring the Supervisor Operator ID / Password TroubleshootingGeneral Test Run Messages Power On Self Test Message / IQC MessagesNo Available Ports. IQC Failed To Start FailInsertion Error Remove & Reinsert Followed by Timed Out ErrorLot Card Messages Settings Messages LQC Related Messages Printer Errors USB Device Errors Communications ErrorsUnrecognized USB Drive Attached, Remove Device Specifications Storage temperature Operating temperatureOperating Humidity Operating/Storage3M Rapid Detection Reader IndexRestoring Supervisor Operator ID Password Languages Upgrading Software See RCU USB