Editing Settings Using the Reader Configuration Utility (RCU)

3.Enter the Web server directory. Contact the local IT administrator for the appropriate Web server directory.

4.Save your settings by selecting File > Save from the menu.

No additional setup is required to access configuration files on a network shared drive.

Accessing Configuration Files

A Group is defined as a common configuration shared by multiple Readers. As many Groups as necessary can be defined. Each Group MUST have its own Directory. A Directory contains a set of configuration files that define how the Readers in that Group operate. For example, one Group may be defined for Readers in an emergency department environment with files saved in a directory “ED”, while a separate set of configuration files, for use in an intensive care setting, would be defined in the Group “ICU” and saved in a directory “ICU”.

A default Group Directory (C:\Program Files\Reader Configuration\) is set up during software installation. If only one group is needed, the initial files can be modified and saved in this directory.

If more than one group is needed, copy the default folder (C:\Program Files\Reader Configuration) and re-name or use the Save As command to save all files to a new directory. Each new folder MUST contain the following files: assays.dtv, controls.dtv, grp_settings.dtv, and, userlist.opl.

If transferring files by USB, all files in the Group Directory MUST be copied to the root directory of the USB.

CAUTION.

Do not change the file names.

To open all files for a group

Figure 40. Reader Configuration

Click File > Open Group..., select the folder containing the files to be

System Settings: File

 

used and click OK. If only one group is being used, the default

 

location is C:\Program Files\Reader Configuration\. This will open the

 

following files: group settings, userlist, controls and assays.

 

Detailed information on the use of the RCU files can be found in the

 

RCU HELP sections.

 

31

Image 36
Contents Operator Manual Made in Canada for Table of Contents Maintenance Iii Read all contents of this manual prior to use Consult Accompanying Documents Consult Operator ManualSummary of Warnings and Precautions To reduce the risk of instrument or accessory damageTo reduce the risk associated with hazardous voltage To reduce the risk associated with incorrect resultsIntroduction OverviewIntended Use Unpacking and Setup Optional Accessories Available from 3M3M Rapid Detection Reader Components 3M Rapid Detection Reader Setup To set-up 3M Rapid Detection ReaderBarcode Scanner § 3M Rapid Detection Control Module CM3M Rapid Detection Reader 3M Rapid Detection Control Module 3M Rapid Detection Test Module CM PortReader Configuration Utility RCU supplied with the CM. For 3M Rapid Detection Reader ModulesTurning on the 3M Rapid Detection Reader Display Icons Port Identification NomenclatureUsing Lot Cards Performing an AssayStarting an Assay Operator Entry Running Quality Control AcceptLQC Icons Assay Status WarningsRunning IQC To run IQC manuallyTo run IQC automatically Working with Results and Logs Viewing Saved ResultsViewing Saved Logs Searching Results Searching LogsManually Transferring / Printing Results or Logs Results TransferManaging Settings LQCSettings View Tabs AssayTimer Login PrinterLogin Requirements Network SettingsFile Privilege RequirementsSettings View About Tab AboutEdit Settings Settings Edit TabsTimers Manual / Auto Transfer Mode Date/TimeLanguage MiscRestoring Defaults Managing OperatorsSound Adding/Modifying an Operator To Add an OperatorTouch Search or Cancel Searching for an Individual OperatorTo Modify an Operator Editing Settings Using the Reader Configuration Utility RCU InstallationLogin Getting StartedEmergency Password Reset Mechanism Choosing a Configuration File Access MethodSetting Up a USB Flash Drive Setting Up Web Services AccessAccessing Configuration Files To open all files for a groupSetting Up Communications Between RCU and Readers To open an Individual Configuration FileFiles Identifying Readers through the RCU Non-networked EnvironmentNetworked Environment Touch Export to USB Flash DriveImporting Files Exporting FilesDeleting Results Delete Results Prior to DateMaintenance Exterior CleaningPossible device damage Upgrading Device Software Disposal of EquipmentTroubleshooting Restoring the Supervisor Operator ID / PasswordGeneral Power On Self Test Message / IQC Messages Test Run MessagesNo Available Ports. IQC Failed To Start FailError Insertion Error Remove & Reinsert Followed by Timed OutLot Card Messages Settings Messages LQC Related Messages Printer Errors Communications Errors USB Device ErrorsUnrecognized USB Drive Attached, Remove Device Specifications Operating temperature Storage temperatureOperating Humidity Operating/StorageIndex 3M Rapid Detection ReaderRestoring Supervisor Operator ID Password Languages Upgrading Software See RCU USB