3M™ Rapid Detection ReaderManaging Settings

Settings: Edit Tabs

Tab

Screen

Misc. continued

Sound

Edit on CM. Cannot edit through RCU. Test: Touch to hear indicator.

On: The audio indicator is ON and sounds at the completion of an assay and when a USB device is connected or disconnected.

Off: The audio indicator is OFF.

Default: On

There is no volume adjustment feature.

Restoring Defaults

NOTE: Restoring device settings to factory defaults will erase all stored settings, assay results and operator information. Back up all device databases prior to restoring factory defaults. To transfer files from the 3M Rapid Detection Reader to another device, see Exporting Files.

1.From the Settings Menu (Figure 20), touch Restore Defaults. The Settings: Restore Defaults screen will open (Figure 33).

2.Touch Restore Defaults to restore factory defaults or Cancel to return the Settings menu.

3.After selecting Restore Defaults, a confirmation prompt will appear. Touch Confirm to restore defaults or Cancel to return to the settings menu.

4.When prompted, turn 3M Rapid Detection Reader off and on again to complete restoration of defaults.

Figure 33. Settings: Restore Defaults

Managing Operators

If an Operator ID or password is required, only individuals with Operator IDs stored on the 3M Rapid Detection Reader can perform assays and LQC, or select Menu options. The operator login requirements can be set on CM and RCU.

To access the Operator List on the Reader:

1.From the Main Menu screen (Figure 4), touch Settings and enter the Operator ID and Password (Figure 6).

The default login for access to the Settings menu is: Operator ID: SUPERVISOR

Password: PASSWORD

Both entries are case-sensitive

Figure 34. Settings: Operators

26

Image 31
Contents Operator Manual Made in Canada for Table of Contents Maintenance Iii Consult Accompanying Documents Consult Operator Manual Read all contents of this manual prior to useTo reduce the risk associated with incorrect results Summary of Warnings and PrecautionsTo reduce the risk of instrument or accessory damage To reduce the risk associated with hazardous voltageOverview IntroductionIntended Use Optional Accessories Available from 3M Unpacking and Setup3M Rapid Detection Reader Components § 3M Rapid Detection Control Module CM 3M Rapid Detection Reader SetupTo set-up 3M Rapid Detection Reader Barcode Scanner3M Rapid Detection Reader 3M Rapid Detection Test Module CM Port 3M Rapid Detection Control Module3M Rapid Detection Reader Modules Reader Configuration Utility RCU supplied with the CM. ForTurning on the 3M Rapid Detection Reader Port Identification Nomenclature Display IconsPerforming an Assay Using Lot CardsStarting an Assay Operator Entry Accept Running Quality ControlAssay Status Warnings LQC IconsTo run IQC manually Running IQCTo run IQC automatically Viewing Saved Results Working with Results and LogsViewing Saved Logs Searching Logs Searching ResultsResults Transfer Manually Transferring / Printing Results or LogsLQC Managing SettingsAssay Settings View TabsTimer Printer LoginPrivilege Requirements Login RequirementsNetwork Settings FileAbout Settings View About TabSettings Edit Tabs Edit SettingsTimers Misc Manual / Auto Transfer ModeDate/Time LanguageManaging Operators Restoring DefaultsSound To Add an Operator Adding/Modifying an OperatorSearching for an Individual Operator Touch Search or CancelTo Modify an Operator Getting Started Editing Settings Using the Reader Configuration Utility RCUInstallation LoginSetting Up Web Services Access Emergency Password Reset MechanismChoosing a Configuration File Access Method Setting Up a USB Flash DriveTo open all files for a group Accessing Configuration FilesTo open an Individual Configuration File Setting Up Communications Between RCU and ReadersFiles Touch Export to USB Flash Drive Identifying Readers through the RCUNon-networked Environment Networked EnvironmentExporting Files Importing FilesDelete Results Prior to Date Deleting ResultsExterior Cleaning MaintenancePossible device damage Disposal of Equipment Upgrading Device SoftwareRestoring the Supervisor Operator ID / Password TroubleshootingGeneral Fail Power On Self Test Message / IQC MessagesTest Run Messages No Available Ports. IQC Failed To StartInsertion Error Remove & Reinsert Followed by Timed Out ErrorLot Card Messages Settings Messages LQC Related Messages Printer Errors USB Device Errors Communications ErrorsUnrecognized USB Drive Attached, Remove Device Specifications Operating/Storage Operating temperatureStorage temperature Operating Humidity3M Rapid Detection Reader IndexRestoring Supervisor Operator ID Password Languages Upgrading Software See RCU USB