Carrier Understanding 230/1/60 Wiring for Air Conditioners

Page 30

NOTES:

1.If any of the original wire furnished must be replaced, it must be replaced with type 90 C wire or its equivalent.

2.Use copper conductors only.

 

 

LEGEND

AWG

Ð

American Wire Gage

BR

Ð

Blower Relay

CÐ Contactor

CAP

Ð

Capacitor

COMP

Ð Compressor Motor

CR

Ð Combustion Relay

DT

Ð

Discharge Thermostat

EQUIP

Ð

Equipment

FL

Ð

Fuse Link

FS

Ð

Flame Sensor

FU

Ð

Fuse

GND

Ð Ground

GVR

Ð Gas Valve Relay

HS

Ð Hall Effect Sensor

HV TRAN

Ð

High-Voltage Transformer

IÐ Ignitor

IDM

Ð

Induced-Draft Motor

IFM

Ð

Indoor-Fan Motor

IGC

Ð

Integrated Gas Control

LS

Ð

Limit Switch

MGV

Ð Main Gas Valve

NEC

Ð

National Electrical Code

OFM

Ð Outdoor-Fan Motor

PWR

Ð Power

QT

Ð Quadruple Terminal

RS

Ð Rollout Switch

ST

Ð

Start Thermistor

TRAN

Ð

Transformer

Field Splice

Terminal (Marked)

Terminal (Unmarked)

Splice

Splice (Marked)

Factory Wiring

Field Control Wiring

Field Power Wiring

Accessory or Optional Wiring

To Indicate Common Potential

Only, Not to Represent Wiring

Fig. 29 Ð 208/230-1-60 Wiring Diagram, Units 48SX024-042

30

Image 30
Contents Contents Safety Considerations48SS018-042 Without Base Rail, Unit Dimensions 48SS018-042 With Optional Base Rail, Unit Dimensions 48SS048,060 Without Base Rail, Unit Dimensions 48SS048,060 With Optional Base Rail, Unit Dimensions 48SX024-036 Without Base Rail, Unit Dimensions 48SX024-036 With Optional Base Rail, Unit Dimensions 48SX042-060 Without Base Rail, Unit Dimensions 48SX042-060 With Optional Base Rail, Unit Dimensions Provide Unit Support Receiving and InstallationCheck Equipment Rig and Place UnitPart Number CurbWeight Unit MAXUnit Connect Condensate Drain Condensate TrapPhysical Data Ð Unit 48SS Unit Size 48SSPhysical Data Ð Unit 48SX Unit Size 48SXSediment Trap Maximum Gas Flow Capacity Supply and Return Duct OpeningsInstall Electrical Connections Vertical Discharge Cover RemovedÐ Electrical Data Ð Unit 48SS RLA LRA Ð Electrical Data Ð Unit 48SXRange Motor FLA MCAHigh- and Control-Voltage Connections PRE-START-UP Easy Select Interface BoardStart Up Heating Section and Make Adjustments START-UPPressure Unit 48SS,SX Rated Gas Inputs at Indicated Manifold PressuresGAS Supply Pressure Manifold Natural GAS Propane Number OrificesHeating Temperature Rise F Input Monoport BurnersStart Up Cooling Section and Make Adjustments Error Code LED IndicationLED Indications 208/230-1-60 Wiring Diagram, Units 48SS018-060 208/230-3-60 Wiring Diagram, Units 48SS030-060 460-3-60 Wiring Diagram, Units 48SS036-060 208/230-1-60 Wiring Diagram, Units 48SX024-042 208/230-1-60 Wiring Diagram, Units 48SX048,060 208/230-3-60 Wiring Diagram, Units 48SX036-042 208/230-3-60 Wiring Diagram, Units 48SX048,060 460-3-60 Wiring Diagram, Units 48SX036-048 Checking and Adjusting Refrigerant Charge Ð Superheat Charging Table, 48SS018 Ð Superheat Charging Table, 48SS024Ð Superheat Charging Table, 48SS030 Ð Superheat Charging Table, 48SS036Ð Superheat Charging Table, 48SS042 Ð Superheat Charging Table, 48SS060 Ð Superheat Charging Table, 48SX024 Ð Superheat Charging Table, 48SX030Ð Superheat Charging Table, 48SX036 Ð Superheat Charging Table, 48SX042 Ð Superheat Charging Table, 48SX048Ð Superheat Charging Table, 48SX060 Temp F Required Suction-Tube Temperature FSuperheat Unit Motor AIRExternal Static Pressure in. wg 48SX Unit 48SX FAN only Cfm Cooling CfmMaintenance Wet Coil Pressure DropUnit Size Airflow Pressure Drop Air Filter Unit Top RemovalEvaporator Blower and Motor Burner Access Panel Condenser Coil, Evaporator Coil, and Conden Condenser FanTroubleshooting CoolingHeating Burners will not igniteService Training LED Troubleshooting Ð Error CodePage Remove and Store in Job File Preliminary InformationIII. START-UP