NOTES:

1.If any of the original wire furnished must be replaced, it must be replaced with type 90 C wire or its equivalent.

2.Use copper conductors only.

 

 

LEGEND

AWG

Ð

American Wire Gage

BR

Ð

Blower Relay

CÐ Contactor

CAP

Ð

Capacitor

COMP

Ð Compressor Motor

CR

Ð Combustion Relay

EQUIP

Ð

Equipment

FL

Ð

Fuse Link

FS

Ð

Flame Sensor

FU

Ð

Fuse

GND

Ð Ground

GVR

Ð Gas Valve Relay

HS

Ð Hall Effect Sensor

HV TRAN

Ð

High-Voltage Transformer

IÐ Ignitor

ICM

Ð

Integrated Control Motor

IDM

Ð

Induced-Draft Motor

IGC

Ð

Integrated Gas Control

LS

Ð

Limit Switch

MGV

Ð Main Gas Valve

NEC

Ð

National Electrical Code

OFM

Ð Outdoor-Fan Motor

PWR

Ð Power

QT

Ð Quadruple Terminal

RS

Ð Rollout Switch

SEC

Ð

Secondary

TRAN

Ð

Transformer

Field Splice

Terminal (Marked)

Terminal (Unmarked)

Splice

Splice (Marked)

Factory Wiring

Field Control Wiring

Field Power Wiring

Accessory or Optional Wiring

To Indicate Common Potential

Only, Not to Represent Wiring

Fig. 30 Ð 208/230-1-60 Wiring Diagram, Units 48SX048,060

31

Image 31
Contents Safety Considerations Contents48SS018-042 Without Base Rail, Unit Dimensions 48SS018-042 With Optional Base Rail, Unit Dimensions 48SS048,060 Without Base Rail, Unit Dimensions 48SS048,060 With Optional Base Rail, Unit Dimensions 48SX024-036 Without Base Rail, Unit Dimensions 48SX024-036 With Optional Base Rail, Unit Dimensions 48SX042-060 Without Base Rail, Unit Dimensions 48SX042-060 With Optional Base Rail, Unit Dimensions Rig and Place Unit Receiving and InstallationCheck Equipment Provide Unit SupportCurb Part NumberUnit MAX WeightUnit Condensate Trap Connect Condensate DrainUnit Size 48SS Physical Data Ð Unit 48SSUnit Size 48SX Physical Data Ð Unit 48SXSediment Trap Supply and Return Duct Openings Maximum Gas Flow CapacityVertical Discharge Cover Removed Install Electrical ConnectionsÐ Electrical Data Ð Unit 48SS FLA MCA Ð Electrical Data Ð Unit 48SXRange Motor RLA LRAHigh- and Control-Voltage Connections Easy Select Interface Board PRE-START-UPSTART-UP Start Up Heating Section and Make AdjustmentsOrifices Rated Gas Inputs at Indicated Manifold PressuresGAS Supply Pressure Manifold Natural GAS Propane Number Pressure Unit 48SS,SXMonoport Burners Heating Temperature Rise F InputError Code LED Indication Start Up Cooling Section and Make AdjustmentsLED Indications 208/230-1-60 Wiring Diagram, Units 48SS018-060 208/230-3-60 Wiring Diagram, Units 48SS030-060 460-3-60 Wiring Diagram, Units 48SS036-060 208/230-1-60 Wiring Diagram, Units 48SX024-042 208/230-1-60 Wiring Diagram, Units 48SX048,060 208/230-3-60 Wiring Diagram, Units 48SX036-042 208/230-3-60 Wiring Diagram, Units 48SX048,060 460-3-60 Wiring Diagram, Units 48SX036-048 Checking and Adjusting Refrigerant Charge Ð Superheat Charging Table, 48SS024 Ð Superheat Charging Table, 48SS018Ð Superheat Charging Table, 48SS036 Ð Superheat Charging Table, 48SS030Ð Superheat Charging Table, 48SS042 Ð Superheat Charging Table, 48SS060 Ð Superheat Charging Table, 48SX030 Ð Superheat Charging Table, 48SX024Ð Superheat Charging Table, 48SX036 Ð Superheat Charging Table, 48SX048 Ð Superheat Charging Table, 48SX042Ð Superheat Charging Table, 48SX060 Unit Motor AIR Required Suction-Tube Temperature FSuperheat Temp FExternal Static Pressure in. wg 48SX FAN only Cfm Cooling Cfm Unit 48SXWet Coil Pressure Drop MaintenanceUnit Size Airflow Pressure Drop Unit Top Removal Air FilterEvaporator Blower and Motor Burner Access Panel Condenser Fan Condenser Coil, Evaporator Coil, and CondenCooling TroubleshootingBurners will not ignite HeatingLED Troubleshooting Ð Error Code Service TrainingPage Preliminary Information Remove and Store in Job FileIII. START-UP