Carrier 48HC Service Manual and Error Code 34 Troubleshooting Guide

Page 34

LEGEND

AWG

Ð

American Wire Gage

BR

Ð

Blower Relay

CÐ Contactor

CAP

Ð

Capacitor

COMP

Ð Compressor Motor

CR

Ð Combustion Relay

EQUIP

Ð

Equipment

FS

Ð

Flame Sensor

FU

Ð

Fuse

GND

Ð Ground

GVR

Ð Gas Valve Relay

HS

Ð Hall Effect Sensor

HV TRAN

Ð

High-Voltage Transformer

IÐ Ignitor

IDM

Ð

Induced-Draft Motor

IFM

Ð

Indoor-Fan Motor

IGC

Ð

Integrated Gas Control

LS

Ð

Limit Switch

MGV

Ð Main Gas Valve

NEC

Ð

National Electrical Code

OFM

Ð Outdoor-Fan Motor

PWR

Ð Power

QT

Ð Quadruple Terminal

RS

Ð Rollout Switch

TRAN

Ð Transformer

 

Field Splice

 

Terminal (Marked)

 

Terminal (Unmarked)

 

Splice

 

Splice (Marked)

 

Factory Wiring

 

Field Control Wiring

 

Field Power Wiring

 

Accessory or Optional Wiring

 

To Indicate Common Potential

 

Only, Not to Represent Wiring

NOTES:

1.If any of the original wire furnished must be replaced, it must be re- placed with type 90 C wire or its equivalent.

2.Use copper conductors only.

Fig. 33 Ð 460-3-60 Wiring Diagram, Units 48SX036-048

34

Image 34
Contents Contents Safety Considerations48SS018-042 Without Base Rail, Unit Dimensions 48SS018-042 With Optional Base Rail, Unit Dimensions 48SS048,060 Without Base Rail, Unit Dimensions 48SS048,060 With Optional Base Rail, Unit Dimensions 48SX024-036 Without Base Rail, Unit Dimensions 48SX024-036 With Optional Base Rail, Unit Dimensions 48SX042-060 Without Base Rail, Unit Dimensions 48SX042-060 With Optional Base Rail, Unit Dimensions Provide Unit Support Receiving and InstallationCheck Equipment Rig and Place UnitPart Number CurbUnit MAX WeightUnit Connect Condensate Drain Condensate TrapPhysical Data Ð Unit 48SS Unit Size 48SSPhysical Data Ð Unit 48SX Unit Size 48SXSediment Trap Maximum Gas Flow Capacity Supply and Return Duct OpeningsInstall Electrical Connections Vertical Discharge Cover RemovedÐ Electrical Data Ð Unit 48SS RLA LRA Ð Electrical Data Ð Unit 48SXRange Motor FLA MCAHigh- and Control-Voltage Connections PRE-START-UP Easy Select Interface BoardStart Up Heating Section and Make Adjustments START-UPPressure Unit 48SS,SX Rated Gas Inputs at Indicated Manifold PressuresGAS Supply Pressure Manifold Natural GAS Propane Number OrificesHeating Temperature Rise F Input Monoport BurnersError Code LED Indication Start Up Cooling Section and Make AdjustmentsLED Indications 208/230-1-60 Wiring Diagram, Units 48SS018-060 208/230-3-60 Wiring Diagram, Units 48SS030-060 460-3-60 Wiring Diagram, Units 48SS036-060 208/230-1-60 Wiring Diagram, Units 48SX024-042 208/230-1-60 Wiring Diagram, Units 48SX048,060 208/230-3-60 Wiring Diagram, Units 48SX036-042 208/230-3-60 Wiring Diagram, Units 48SX048,060 460-3-60 Wiring Diagram, Units 48SX036-048 Checking and Adjusting Refrigerant Charge Ð Superheat Charging Table, 48SS018 Ð Superheat Charging Table, 48SS024Ð Superheat Charging Table, 48SS036 Ð Superheat Charging Table, 48SS030Ð Superheat Charging Table, 48SS042 Ð Superheat Charging Table, 48SS060 Ð Superheat Charging Table, 48SX030 Ð Superheat Charging Table, 48SX024Ð Superheat Charging Table, 48SX036 Ð Superheat Charging Table, 48SX048 Ð Superheat Charging Table, 48SX042Ð Superheat Charging Table, 48SX060 Temp F Required Suction-Tube Temperature FSuperheat Unit Motor AIRExternal Static Pressure in. wg 48SX Unit 48SX FAN only Cfm Cooling CfmWet Coil Pressure Drop MaintenanceUnit Size Airflow Pressure Drop Unit Top Removal Air FilterEvaporator Blower and Motor Burner Access Panel Condenser Coil, Evaporator Coil, and Conden Condenser FanTroubleshooting CoolingHeating Burners will not igniteService Training LED Troubleshooting Ð Error CodePage Preliminary Information Remove and Store in Job FileIII. START-UP