Electric Cooling Units
Installation, Start-Up and
Service Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . .
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
RECEIVING AND INSTALLATION . . . . . . . . . . .
·IDENTIFY UNIT
·INSPECT SHIPMENT
Step 2 Ð Provide Unit Support . . . . . . . . . . . . . . 10
·ROOF CURB
·SLAB MOUNT
·FLUSH MOUNT
Step 3 Ð Field Fabricate Ductwork . . . . . . . . . . . 10 Step 4 Ð Provide Clearances . . . . . . . . . . . . . . . . 10 Step 5 Ð Rig and Place Unit . . . . . . . . . . . . . . . . . 10
·UNITS WITHOUT BASE RAIL
·UNITS WITH OPTIONAL BASE RAIL
Step 6 Ð Connect Condensate Drain . . . . . . . . . 13 Step 7 Ð Install Flue Hood . . . . . . . . . . . . . . . . . . 13 Step 8 Ð Install Gas Piping . . . . . . . . . . . . . . . . . . 13 Step 9 Ð Install Duct Connections . . . . . . . . . . . 16
·CONFIGURING UNITS FOR DOWNFLOW (VERTICAL) DISCHARGE
Step 10 Ð Install Electrical Connections . . . . . 18
·
·SPECIAL PROCEDURES FOR
·CONTROL VOLTAGE CONNECTIONS;
·CONTROL VOLTAGE CONNECTIONS; INTEGRATED CONTROL MOTOR (ICM) UNITS
·HEAT ANTICIPATOR SETTING
·TRANSFORMER PROTECTION
NOTE TO INSTALLER Ð Before the installation, READ THESE INSTRUCTIONS CAREFULLY AND COM- PLETELY. Also, make sure the User's Manual and Replace- ment Guide are left with the unit after installation. The fur- nace is NOT to be used for temporary heating of buildings or structures under construction.
SAFETY CONSIDERATIONS
Installation and servicing of
Fig. 1 Ð Unit 48SX Shown With Optional Base Rail
Untrained personnel can perform basic maintenance func- tions of cleaning coils and ®lters. All other operations should be performed by trained service personnel. When working on
Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for unbrazing operations. Have ®re ex- tinguisher available for all brazing operations.
Improper installation, adjustment, alteration, service, main- tenance, or use can cause carbon monoxide poisoning, ®re, or an explosion which can result in personal injury or unit damage. Consult a quali®ed installer, service agency, or gas supplier for information or assistance. The quali- ®ed installer or agency must use only
Before performing service or maintenance operations on unit, turn off gas supply then unit main power switch. Electrical shock could cause personal injury.
General Ð The 48SS,SX units (see Fig. 1) are fully self- contained, combination Category I gas heating/electric cool- ing units designed for outdoor installation. See Fig.
Manufacturer reserves the right to discontinue, or change at any time, speci®cations or designs without notice and without incurring obligations.
Book | 1 | 4 |
| PC 111 | Catalog No. | Printed in U.S.A. | Form | Pg 1 | Replaces: | |
Tab | 1a | 6a |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|