Troubleshooting | 13 | |||||
|
|
|
|
|
| |
SYMPTOM | POSSIBLE CAUSE(S) | CORRECTIVE ACTION | ||||
Motor will not run | Disconnect switch is off | Be sure switch is on. | ||||
| Fuse is blown or circuit breaker tripped | Replace fuse or reset circuit breaker. | ||||
| Starting switch is defective | DISCONNECT POWER; Replace starting switch. | ||||
| Wires at motor are loose, | Refer to instructions on wiring (Page 9). DISCONNECT POWER; check and | ||||
| disconnected, or wired incorrectly | tighten all wiring. | ||||
|
|
|
|
| Capacitor voltage may be hazardous. To discharge | |
|
|
|
|
| ||
|
|
|
| |||
|
| capacitor, hold insulated handle screwdriver BY THE HANDLE and | ||||
|
| short capacitor terminals together. Do not touch metal screwdriver | ||||
|
| blade or capacitor terminals. If in doubt, consult a qualified electrician. | ||||
| Pressure switch contacts are dirty | DISCONNECT POWER and file contacts with emery board or nail file. | ||||
|
|
|
|
|
| |
Motor runs hot and | Motor is wired incorrectly | Refer to instructions on wiring. | ||||
overload kicks off | Voltage is too low | Check with power company. Install heavier wiring if wire size is too small | ||||
| ||||||
|
| (See Electrical / Wiring Chart). | ||||
| Pump cycles too frequently | See section below on too frequent cycling. | ||||
|
|
|
|
|
| |
Motor runs but no | Pump in new installation did | In new installation: | ||||
water is delivered* | not pick up prime through: |
|
|
|
| |
| 1. Improper priming | 1. | ||||
| 2. Air leaks | 2. Check all connections on suction line, AVC, and ejector with | ||||
|
|
| soapy water or shaving cream. | |||
* (Note: Stop pump; | 3. Leaking foot valve or check valve | 3. Replace foot valve or check valve. | ||||
then check prime | Pump has lost prime through: | In installation already in use: | ||||
before looking for | 1. Air leaks | 1. Check all connections on suction line and shaft seal. | ||||
other causes. | 2. Water level below suction pipe inlet | 2. Lower suction line into water and | ||||
Unscrew priming |
|
| in well exceeds 25’ (7.6M), a deep well pump is needed. | |||
plug and see if water | Foot valve or strainer is plugged | Clean foot valve or strainer. | ||||
is in priming hole). | ||||||
Ejector or impeller is plugged | Clean ejector or impeller. | |||||
| ||||||
| Check valve or foot valve is stuck shut | Replace check valve or foot valve. | ||||
| Pipes are frozen | Thaw pipes. Bury pipes below frost line. Heat pit or pump house. | ||||
| Foot valve and/or strainer are | Raise foot valve and/or strainer above bottom of water source. | ||||
| buried in sand or mud | Clean foot valve and strainer. | ||||
| Water level is too low for shallow | A deep well jet will be needed if your well is more than 25’ (7.6M) | ||||
| well setup to deliver water | depth to water. | ||||
|
|
|
|
|
| |
Pump does not | Water level in well is lower than | A new nozzle and venturi combination may be needed. | ||||
deliver water to full | estimated |
|
|
|
| |
capacity | Steel piping (if used) is corroded or | Replace with plastic pipe where possible, otherwise with new steel pipe. | ||||
(Also check point | ||||||
limed, causing excess friction |
|
|
|
| ||
3 immediately above) |
|
|
|
| ||
Piping is too small in size | Use larger piping. | |||||
| ||||||
|
|
|
|
|
| |
Pump delivers water but | Pressure switch is out of adjustment or | DISCONNECT POWER; adjust or replace pressure switch. | ||||
does not shut off or | contacts are welded together |
|
|
|
| |
pump cycles too | Faucets have been left open | Close faucets. | ||||
frequently | Venturi, nozzle or impeller is clogged | Clean venturi, nozzle or impeller. | ||||
| ||||||
| Standard pressure tank is waterlogged | Drain tank to air volume control port. Check AVC for defects. Check | ||||
| and has no air cushion | all connections for air leaks. | ||||
| Pipes leak | Check connections. | ||||
| Foot valves leak | Replace foot valve. | ||||
| Pressure switch is out of adjustment | Adjust or replace pressure switch. | ||||
| Air charge too low in | DISCONNECT POWER and open faucets until all pressure is relieved. | ||||
|
| Using tire pressure gauge, check air pressure in tank at valve stem | ||||
|
| located on the tank. If less than pressure switch | ||||
|
| PSI), pump air into tank from outside source until air pressure is 2 PSI | ||||
|
| less than | ||||
|
| solution) and replace core if necessary. | ||||
|
|
|
|
|
| |
Air spurts from faucets | Pump is picking up prime | When pump has picked up prime, it should pump solid water with no air. | ||||
| Leak in suction side of pump | Suction pipe is sucking air. Check joints for leaks with soapy water. | ||||
| Well is gaseous | Consult factory about installing a sleeve in the well. | ||||
| Intermittent | Lower foot valve if possible, otherwise restrict pump discharge. | ||||
| (Water drawn down below foot valve.) |
|
|
|
| |
|
|
|
|
|
|
For parts or assistance, call Simer Customer Service at