18.2When a battery is very cold, partially charged or sulfated, it will not draw the full rated amperes from the charger. It is dangerous and damaging to a battery to force higher amperage into it than it can effectively use in recharging.
18.3When an unknown operating problem arises, please read the complete manual and call the customer service number for information. Doing so will usually eliminate the need for return.
If the above solutions do not eliminate the problem or for information about troubleshooting or replacement parts, call
7:00 am to 5:00 pm Central Time Monday thru Friday
19.technical specifications
This charger is intended for use with
| Electrical | |
Nominal Operating Voltage (VAC) |
| 100 – 240 |
Input Voltage Range (VAC) |
| 85 – 264 |
Input Current (A rsm max) |
| 2.9 @ 85V 60Hz |
Output Power (W) |
| 120 nom. 130 max. |
Output Current (A max) |
| 5.0 |
Output Voltage (VDC nom./ |
| 24 / 2 – 29.5 |
range) |
|
|
|
| |
Mechanical | ||
Case |
| Black Anodized Aluminum |
Dimensions (inches) |
| 7 L x 5½ W x 2 H |
Weight |
| 1.80 lbs |
|
| |
Connections | ||
AC Power Input |
| C13 Male Socket |
DC Power Output Adapters |
| Option #1 – Battery Clamp Output Cord |
|
| Option #2 – |
|
| Option #3 – 3/8” Dia. Ring Terminal Output |
|
| Cord |
• 10 •