Samsung AP50M0ANXSG Battery changing time, Storing the remote controller, Inserting the batteries

Page 13

Battery changing time

When the battery is exhausted,( )will be displayed in the remote controller display. When the icon appears, change the batteries. The remote controller requires two 1.5V AAA type batteries.

Storing the remote controller

When you do not use the remote controller for a long time, remove the batteries from the remote controller and store it in the remote controller holder.

Inserting the batteries

1. Open the battery cover.

ffPush the ( ) part in the direction of the arrow and lift up the cover.

2. Insert the batteries.

ffCheck and match the (+), (-) signs and insert them in correct position.

3. Close the battery cover.

ffMatch the cover and bottom part of the remote controller and press it until you hear click sound.

Make sure that water is not allowed to enter the remote controller.

CAUTION

 

 

 

There is a possibility that the air conditioner will not operate by remote controller near strong light such as a

 

 

 

 

fluorescent lamp or neon sign. In this case, use the remote controller in front of the remote controller receiver of the

NOTE

 

 

indoor unit.

 

 

 

 

 

 

 

If other electrical products are operated by the remote controller, call your nearest service center.

ENGLISH

13

Mirage_AP50M0@_IBIM_EN_05323A-02.indd 13

2016-05-19 오후 1:27:13

Image 13
Contents Thank you for purchasing this Samsung product Air ConditionerStrong Turbo/Long Function Features of your new air conditionerLook for Everywhere Contents Important safety symbols and precautions Safety precautionsDo not yank the power cable with hands Ensure no water gets into the air conditioner FfPotential risk of injury or electric shock Use a rated circuit breaker onlyFfPotential risk of personal injury Do not open the front panel during operationFfInsufficient ventilation may result in poor performance Do not allow children to climb on the air conditionerFfPotential risk of personal injury or property loss FfWearing thick gloves can protect your hands Checking the indoor unit and display Viewing your air conditionerMain parts To open the panelHeater and Purity function is not supported by this model Control panelRemote controller buttons Checking the remote controllerUsing the remote controller Remote controller displayAre in the same space Storing the remote controller Battery changing timeInserting the batteries Indoor unitBasic operation Selecting the operation mode Turning on the powerAdjusting the desired temperature Selecting the fan speedSelecting air flow direction When the air conditioner is off Setting the On/Off timerYou cannot set the fan speed when setting the On timer Controller displayButton When the air conditioner is onWhen the air conditioner is operating in Cool or Heat mode Using the Turbo functionLocking the control panel Using the Long functionUsing the air conditioner with the control panel Cleaning the exterior Cleaning and maintaining the air conditionerCleaning the filter Air filter Maintaining your air conditioner Installation partPeriodical checks Internal protections via the unit control system Have deposited at low temperaturesAppendix TroubleshootingHumidity Operation rangesOr accessing its internal components Installing the unitGeneral information PersonnelDo not install the air conditioner in following places Power supply line, fuse or circuit breakerMake sure that you earth the cables Complete, electric shock or fire may occurAccessory parts list Indoor unit Selection of installation placeTop view Side viewOutdoor unit Selecting appropriate location for installation Preparing the installationVentilate Wear protective goggles and mask before spraying Space requirementsElectrical work Wiring standardCord. Code designation IEC60245 IEC 66 / CENELECH07RN-F Ssc *2Using 4poles ELCBEarth Leakage Circuit Breaker Indoor and outdoor connection wiringAP50M0 Series AP50M1 Series Using 3poles Elcb and 2poles ElcbConnecting the power terminal Electrical wiringOutdoor unit When using the anchor bolt Installation methodWhen using the rubber leg Installation proceduresTrap Refrigerant pipe work Insulating the pipes Check the following list and install an oil trapOil trap FfRadius of curvature R on the oil trap are as followsConnection of refrigerant piping Flare processing Cut the pipe using the pipe cutterRemove burr on the edge of pipe It may cause explosion and injuryTightening of connection parts Pipe bendingDrilling a hole in the wall Drain hose Wall installation Corner InstallationFixing the indoor unit ExampleBe sure that all valve cocks are closed Air purgeRefrigerant charging How to add refrigerantCheck the stability of the pressure for 10 minutes Check Check and test operationIs grounding properly made? When the outdoor temperature is below zero, do not Pump down procedure When removing the productTest operation Packing and unpacking guide Outdoor unit Mm of the wire shields of the tube How to connect your extended power cablesPrepare the following tools TubeApply heat to the contraction tube to contract it FfMethodMirageAP50M0@IBIMEN05323A-02.indd 2016-05-19 오후 English Questions or COMMENTS?