Cleaning and maintaining the air conditioner

Make sure to turn off the circuit breaker when cleaning the air conditioner.

CAUTION

Cleaning the exterior

1. Wipe the surface of the unit with a slightly wet or dry cloth when needed.

Do not use Benzene, Thinner or CloroxTM. They may damage the surface of the air conditioner and can CAUTION create a risk of fire.

Cleaning the filter

Air filter

Washable air filter captures large particles from the air.

The filter can be cleaned with a vacuum or by hand washing.

1.Open the panel and pull out the air filter after removing the tape that holds the air filter. Pull out the air filter in the direction of the arrow as shown in the below figure.

Air Filter

Tape

2.Clean the air filter with a vacuum cleaner or in running water.

If dust is too heavy, use warm water mixed with detergent. Do not scrub the filter too hard since it may get damaged.

3.Dry the air filter in a ventilated area.

Do not dry the air filter in a place with direct sunlight.

4. Insert the air filter back in its original position. Make sure it is firmly fixed.

Clean the air filter every two weeks. Cleaning term may differ depending on usage and environmental conditions.

NOTE

22

Mirage_AP50M0@_IBIM_EN_05323A-02.indd 22

2016-05-19 오후 1:27:18

Image 22
Contents Air Conditioner Thank you for purchasing this Samsung productStrong Turbo/Long Function Features of your new air conditionerLook for Everywhere Contents Important safety symbols and precautions Safety precautionsDo not yank the power cable with hands Ensure no water gets into the air conditioner FfPotential risk of personal injury Use a rated circuit breaker onlyFfPotential risk of injury or electric shock Do not open the front panel during operationFfInsufficient ventilation may result in poor performance Do not allow children to climb on the air conditionerFfPotential risk of personal injury or property loss FfWearing thick gloves can protect your hands Main parts Viewing your air conditionerChecking the indoor unit and display To open the panelControl panel Heater and Purity function is not supported by this modelChecking the remote controller Remote controller buttonsUsing the remote controller Remote controller displayAre in the same space Inserting the batteries Battery changing timeStoring the remote controller Indoor unitBasic operation Adjusting the desired temperature Turning on the powerSelecting the operation mode Selecting the fan speedSelecting air flow direction You cannot set the fan speed when setting the On timer Setting the On/Off timerWhen the air conditioner is off Controller displayWhen the air conditioner is on ButtonUsing the Turbo function When the air conditioner is operating in Cool or Heat modeUsing the Long function Locking the control panelUsing the air conditioner with the control panel Cleaning the exterior Cleaning and maintaining the air conditionerCleaning the filter Air filter Maintaining your air conditioner Installation partPeriodical checks Have deposited at low temperatures Internal protections via the unit control systemTroubleshooting AppendixOperation ranges HumidityGeneral information Installing the unitOr accessing its internal components PersonnelMake sure that you earth the cables Power supply line, fuse or circuit breakerDo not install the air conditioner in following places Complete, electric shock or fire may occurAccessory parts list Top view Selection of installation placeIndoor unit Side viewOutdoor unit Selecting appropriate location for installation Preparing the installationVentilate Space requirements Wear protective goggles and mask before sprayingCord. Code designation IEC60245 IEC 66 / CENELECH07RN-F Wiring standardElectrical work Ssc *2Using 4poles ELCBEarth Leakage Circuit Breaker Indoor and outdoor connection wiringAP50M0 Series Using 3poles Elcb and 2poles Elcb AP50M1 SeriesElectrical wiring Connecting the power terminalWhen using the rubber leg Installation methodOutdoor unit When using the anchor bolt Installation proceduresTrap Oil trap Check the following list and install an oil trapRefrigerant pipe work Insulating the pipes FfRadius of curvature R on the oil trap are as followsRemove burr on the edge of pipe Cut the pipe using the pipe cutterConnection of refrigerant piping Flare processing It may cause explosion and injuryTightening of connection parts Pipe bendingDrilling a hole in the wall Fixing the indoor unit Wall installation Corner InstallationDrain hose ExampleAir purge Be sure that all valve cocks are closedRefrigerant charging How to add refrigerantCheck the stability of the pressure for 10 minutes Check Check and test operationIs grounding properly made? When the outdoor temperature is below zero, do not Pump down procedure When removing the productTest operation Packing and unpacking guide Outdoor unit Prepare the following tools How to connect your extended power cablesMm of the wire shields of the tube TubeFfMethod Apply heat to the contraction tube to contract itMirageAP50M0@IBIMEN05323A-02.indd 2016-05-19 오후 English Questions or COMMENTS?