Samsung AP50M1ANXSG, AP50M0ANXSG manual When the air conditioner is on, Button

Page 18

Setting the On/Off timer

When the air conditioner is on;

1. Press the Timer button to select (Off).

- (Off) indicator starts to blink and you can set the time.

2. Press the < or > button to set the time.

-You can set the time in 0.5 hour unit from 0.5 ~ 3 hours and 1 hour unit from 3~24 hours.

- Time can be set from minimum 0.5 hours to maximum 24 hours.

3.Press the SET button to complete the Off timer setting.

-(Off) indicator and the set time of the timer will be displayed on the remote controller display and the Timer indicator () will be displayed on the indoor unit display.

-Off timer setting will be cancelled if you don't press the SET button within 10 seconds after setting the time. Therefore check for the (Off) indicator on

the remote controller display and the Timer indicator () on the indoor unit display.

Cancel ffPress the Timer button Select (Off) Press the < or > button Set the time to Press the SET button.

Combining On Timer and Off Timer

When the air conditioner is off

When the air conditioner is on

 

 

When set time on On timer is shorter than Off timer

When set time on On timer is longer than Off timer

Ex) On timer: 3 hours, Off timer: 5 hours

Ex) On timer: 3 hours, Off timer: 1 hour

- The air conditioner will turn on after 3 hours from

- The air conditioner will turn off after 1 hour from the

the moment you have set the timer and the air

moment you have set the timer and turn on after 2 hours

conditioner will remain on for 2 hours and then turn off

from the moment it was turned off.

automatically.

 

 

 

 

 

Set time for the On timer and the Off timer should be different from each other.

 

 

 

When the On timer or the Off timer is set, setting can be cancelled by pressing the Power

NOTE

button.

18

Mirage_AP50M0@_IBIM_EN_05323A-02.indd 18

2016-05-19 오후 1:27:15

Image 18
Contents Air Conditioner Thank you for purchasing this Samsung productFeatures of your new air conditioner Strong Turbo/Long FunctionLook for Everywhere Contents Safety precautions Important safety symbols and precautionsDo not yank the power cable with hands Ensure no water gets into the air conditioner FfPotential risk of personal injury Use a rated circuit breaker onlyFfPotential risk of injury or electric shock Do not open the front panel during operationDo not allow children to climb on the air conditioner FfInsufficient ventilation may result in poor performanceFfPotential risk of personal injury or property loss FfWearing thick gloves can protect your hands Main parts Viewing your air conditionerChecking the indoor unit and display To open the panelControl panel Heater and Purity function is not supported by this modelChecking the remote controller Remote controller buttonsRemote controller display Using the remote controllerAre in the same space Inserting the batteries Battery changing timeStoring the remote controller Indoor unitBasic operation Adjusting the desired temperature Turning on the powerSelecting the operation mode Selecting the fan speedSelecting air flow direction You cannot set the fan speed when setting the On timer Setting the On/Off timerWhen the air conditioner is off Controller displayWhen the air conditioner is on ButtonUsing the Turbo function When the air conditioner is operating in Cool or Heat modeUsing the Long function Locking the control panelUsing the air conditioner with the control panel Cleaning and maintaining the air conditioner Cleaning the exteriorCleaning the filter Air filter Installation part Maintaining your air conditionerPeriodical checks Have deposited at low temperatures Internal protections via the unit control systemTroubleshooting AppendixOperation ranges HumidityGeneral information Installing the unitOr accessing its internal components PersonnelMake sure that you earth the cables Power supply line, fuse or circuit breakerDo not install the air conditioner in following places Complete, electric shock or fire may occurAccessory parts list Top view Selection of installation placeIndoor unit Side viewOutdoor unit Preparing the installation Selecting appropriate location for installationVentilate Space requirements Wear protective goggles and mask before sprayingCord. Code designation IEC60245 IEC 66 / CENELECH07RN-F Wiring standardElectrical work Ssc *2Indoor and outdoor connection wiring Using 4poles ELCBEarth Leakage Circuit BreakerAP50M0 Series Using 3poles Elcb and 2poles Elcb AP50M1 SeriesElectrical wiring Connecting the power terminalWhen using the rubber leg Installation methodOutdoor unit When using the anchor bolt Installation proceduresTrap Oil trap Check the following list and install an oil trapRefrigerant pipe work Insulating the pipes FfRadius of curvature R on the oil trap are as followsRemove burr on the edge of pipe Cut the pipe using the pipe cutterConnection of refrigerant piping Flare processing It may cause explosion and injuryPipe bending Tightening of connection partsDrilling a hole in the wall Fixing the indoor unit Wall installation Corner InstallationDrain hose ExampleAir purge Be sure that all valve cocks are closedHow to add refrigerant Refrigerant chargingCheck the stability of the pressure for 10 minutes Check and test operation CheckIs grounding properly made? Pump down procedure When removing the product When the outdoor temperature is below zero, do notTest operation Packing and unpacking guide Outdoor unit Prepare the following tools How to connect your extended power cablesMm of the wire shields of the tube TubeFfMethod Apply heat to the contraction tube to contract itMirageAP50M0@IBIMEN05323A-02.indd 2016-05-19 오후 English Questions or COMMENTS?