Troubleshooting

Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.

PROBLEM

 

 

 

 

 

 

 

 

 

 

 

SOLUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The air conditioner does not operate

• Because of the protective mechanism, the appliance does not start operating

immediately after it has been

immediately to keep the unit from overloading. The air conditioner will start in 3

restarted.

minutes.

The air conditioner does not work

• Check if the circuit breaker is switched off.

at all.

• Check if there is a power failure.

 

• Check your fuse. Make sure it is not blown out.

The temperature does not change.

• Check if you selected Fan mode. Press the Mode button on the remote controller to

 

select another mode.

The cool(warm) air does not come

• Check if the set temperature is higher (lower) than the current temperature. Press the

out of the air conditioner.

Temp + or - button on the remote controller to change the set temperature. Press the

 

Temp + or - button to increase or decrease the temperature.

 

• Check if the air filter is blocked by dirt. Clean the Air filter every two weeks.

 

• If the air conditioner has just been turned on or the indoor temperature reaches

 

the desired temperature, only fan will operate around 3 minutes for the product

 

protection. Also, just after you start the heating operation, warm air will come out after

 

for a while to avoid cold air from coming out.

The fan speed does not change.

• Check if you selected Auto or Dry mode. The air conditioner automatically adjusts the

 

fan speed to Auto in Auto/Dry mode.

Timer function does not set.

• Check if you press the Set button on the remote controller after you have set the time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Odors permeate in the room during

• Check if the appliance is running in a smoky area or if there is a smell entering from

operation.

outside. Operate the air conditioner in Fan mode or open the windows to air out the

 

room.

The air conditioner makes a bubbling

• A bubbling sound may be heard when the refrigerant is circulating through the

sound.

compressor. Let the air conditioner operate in a selected mode.

Water is dripping from the air flow

• Check if the air conditioner has been cooling for an extended period of time with the

blades.

air flow blades pointed downwards. Condensation may generate due to the difference

 

in temperature.

Remote controller is not working.

• Check if your batteries are depleted.

 

• Make sure batteries are correctly installed.

 

• Make sure nothing is blocking your remote control sensor.

 

• Check that there are strong lighting apparatus near the air conditioner. Strong light

 

which comes from fluorescent bulbs or neon signs may interrupt the electric waves.

Smoke is generated from the

• It may not be a fire but it can be a steam generated by the defrost operation from

outdoor unit.

outdoor heat exchanger during Heat mode in winter.

Error is indicated.

• Contact the service center when the following errors are indicated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGLISH

25

Mirage_AP50M0@_IBIM_EN_05323A-02.indd 25

2016-05-19 오후 1:27:19

Image 25
Contents Thank you for purchasing this Samsung product Air ConditionerStrong Turbo/Long Function Features of your new air conditionerLook for Everywhere Contents Important safety symbols and precautions Safety precautionsDo not yank the power cable with hands Ensure no water gets into the air conditioner FfPotential risk of injury or electric shock Use a rated circuit breaker onlyFfPotential risk of personal injury Do not open the front panel during operationFfInsufficient ventilation may result in poor performance Do not allow children to climb on the air conditionerFfPotential risk of personal injury or property loss FfWearing thick gloves can protect your hands Checking the indoor unit and display Viewing your air conditionerMain parts To open the panelHeater and Purity function is not supported by this model Control panelRemote controller buttons Checking the remote controllerUsing the remote controller Remote controller displayAre in the same space Storing the remote controller Battery changing timeInserting the batteries Indoor unitBasic operation Selecting the operation mode Turning on the powerAdjusting the desired temperature Selecting the fan speedSelecting air flow direction When the air conditioner is off Setting the On/Off timerYou cannot set the fan speed when setting the On timer Controller displayButton When the air conditioner is onWhen the air conditioner is operating in Cool or Heat mode Using the Turbo functionLocking the control panel Using the Long functionUsing the air conditioner with the control panel Cleaning the exterior Cleaning and maintaining the air conditionerCleaning the filter Air filter Maintaining your air conditioner Installation partPeriodical checks Internal protections via the unit control system Have deposited at low temperaturesAppendix TroubleshootingHumidity Operation rangesOr accessing its internal components Installing the unitGeneral information PersonnelDo not install the air conditioner in following places Power supply line, fuse or circuit breakerMake sure that you earth the cables Complete, electric shock or fire may occurAccessory parts list Indoor unit Selection of installation placeTop view Side viewOutdoor unit Selecting appropriate location for installation Preparing the installationVentilate Wear protective goggles and mask before spraying Space requirementsElectrical work Wiring standardCord. Code designation IEC60245 IEC 66 / CENELECH07RN-F Ssc *2Using 4poles ELCBEarth Leakage Circuit Breaker Indoor and outdoor connection wiringAP50M0 Series AP50M1 Series Using 3poles Elcb and 2poles ElcbConnecting the power terminal Electrical wiringOutdoor unit When using the anchor bolt Installation methodWhen using the rubber leg Installation proceduresTrap Refrigerant pipe work Insulating the pipes Check the following list and install an oil trapOil trap FfRadius of curvature R on the oil trap are as followsConnection of refrigerant piping Flare processing Cut the pipe using the pipe cutterRemove burr on the edge of pipe It may cause explosion and injuryTightening of connection parts Pipe bendingDrilling a hole in the wall Drain hose Wall installation Corner InstallationFixing the indoor unit ExampleBe sure that all valve cocks are closed Air purgeRefrigerant charging How to add refrigerantCheck the stability of the pressure for 10 minutes Check Check and test operationIs grounding properly made? When the outdoor temperature is below zero, do not Pump down procedure When removing the productTest operation Packing and unpacking guide Outdoor unit Mm of the wire shields of the tube How to connect your extended power cablesPrepare the following tools TubeApply heat to the contraction tube to contract it FfMethodMirageAP50M0@IBIMEN05323A-02.indd 2016-05-19 오후 English Questions or COMMENTS?