Samsung AP50M0ANXSG, AP50M1ANXSG manual General information, Installing the unit, Personnel

Page 27

Installation manual

Safety precautions

Carefully follow the precautions listed as below because they are essential to guarantee the safety of SAMSUNG product.

 

• Always disconnect the air conditioner from the power supply before servicing it

WARNING

 

or accessing its internal components.

Verify that installation and testing operations are performed by qualified

 

 

personnel.

 

Verify that the air conditioner is not installed in an easily accessible area.

 

 

 

General information

ffCarefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation.

ffFor maximum safety, installers should always carefully read the following warnings.

ffStore the manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred.

ffThis manual explains how to install an indoor unit with a split system with two SAMSUNG units. The use of other types of units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units.

ffThe manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and hydraulic lines. Failure to comply with these instructions or to comply with the requirements set forth in the“Operating limits” table, included in the manual, shall immediately invalidate the warranty.

ffThe air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry.

ffDo not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.

ffIn order to prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.

ffAlways remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations should be performed by qualified personnel only.

ffThe unit contains moving parts, which should always be kept out of the reach of children.

ffDo not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, these operations may cause electric shocks or fires.

ffDo not place containers with liquids or other objects on the unit.

ffAll the materials used for the manufacture and packaging of the air conditioner are recyclable.

ffThe packing material and exhaust batteries of the remote controller(optional) must be disposed of in accordance with current laws.

ffThe air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely.

Installing the unit

IMPORTANT : When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes.

ffUpon receipt, inspect the product to verify that it has not been damaged during transport. If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer).

ffAfter completing the installation, always carry out a functional test and provide the instructions on how to operate the air conditioner to the user.

ENGLISH

27

Mirage_AP50M0@_IBIM_EN_05323A-02.indd 27

2016-05-19 오후 1:27:19

Image 27
Contents Thank you for purchasing this Samsung product Air ConditionerFeatures of your new air conditioner Strong Turbo/Long FunctionLook for Everywhere Contents Safety precautions Important safety symbols and precautionsDo not yank the power cable with hands Ensure no water gets into the air conditioner Do not open the front panel during operation Use a rated circuit breaker onlyFfPotential risk of injury or electric shock FfPotential risk of personal injuryDo not allow children to climb on the air conditioner FfInsufficient ventilation may result in poor performanceFfPotential risk of personal injury or property loss FfWearing thick gloves can protect your hands To open the panel Viewing your air conditionerChecking the indoor unit and display Main partsHeater and Purity function is not supported by this model Control panelRemote controller buttons Checking the remote controllerRemote controller display Using the remote controllerAre in the same space Indoor unit Battery changing timeStoring the remote controller Inserting the batteriesBasic operation Selecting the fan speed Turning on the powerSelecting the operation mode Adjusting the desired temperatureSelecting air flow direction Controller display Setting the On/Off timerWhen the air conditioner is off You cannot set the fan speed when setting the On timerButton When the air conditioner is onWhen the air conditioner is operating in Cool or Heat mode Using the Turbo functionLocking the control panel Using the Long functionUsing the air conditioner with the control panel Cleaning and maintaining the air conditioner Cleaning the exteriorCleaning the filter Air filter Installation part Maintaining your air conditionerPeriodical checks Internal protections via the unit control system Have deposited at low temperaturesAppendix TroubleshootingHumidity Operation rangesPersonnel Installing the unitOr accessing its internal components General informationComplete, electric shock or fire may occur Power supply line, fuse or circuit breakerDo not install the air conditioner in following places Make sure that you earth the cablesAccessory parts list Side view Selection of installation placeIndoor unit Top viewOutdoor unit Preparing the installation Selecting appropriate location for installationVentilate Wear protective goggles and mask before spraying Space requirementsSsc *2 Wiring standardElectrical work Cord. Code designation IEC60245 IEC 66 / CENELECH07RN-FIndoor and outdoor connection wiring Using 4poles ELCBEarth Leakage Circuit BreakerAP50M0 Series AP50M1 Series Using 3poles Elcb and 2poles ElcbConnecting the power terminal Electrical wiringInstallation procedures Installation methodOutdoor unit When using the anchor bolt When using the rubber legTrap FfRadius of curvature R on the oil trap are as follows Check the following list and install an oil trapRefrigerant pipe work Insulating the pipes Oil trapIt may cause explosion and injury Cut the pipe using the pipe cutterConnection of refrigerant piping Flare processing Remove burr on the edge of pipePipe bending Tightening of connection partsDrilling a hole in the wall Example Wall installation Corner InstallationDrain hose Fixing the indoor unitBe sure that all valve cocks are closed Air purgeHow to add refrigerant Refrigerant chargingCheck the stability of the pressure for 10 minutes Check and test operation CheckIs grounding properly made? Pump down procedure When removing the product When the outdoor temperature is below zero, do notTest operation Packing and unpacking guide Outdoor unit Tube How to connect your extended power cablesMm of the wire shields of the tube Prepare the following toolsApply heat to the contraction tube to contract it FfMethodMirageAP50M0@IBIMEN05323A-02.indd 2016-05-19 오후 English Questions or COMMENTS?