Do not allow children to climb on the air conditioner.

Do not use the air conditioner as a cooling precision instrument for food, pets, plants, cosmetics or machinery. Do not pull or give excessive shock to the air conditioner.

ffPotential risk of fire, or unit malfunction and there are risk of personal injury because unit may fall down.

Do not spray water directly on the air conditioner or use benzene, thinner or alcohol to clean the surface of the unit.

ffPotential risk of electric shock or fire.

ffPotential risk of damage to the air conditioner.

Do not place any objects, especially containers with liquid.

Do not touch the pipe connected to the air conditioner.

Install the indoor unit away from lighting apparatus using the ballast.

fIfyou use the wireless remote controller, reception error may occur due to the ballast of the lighting apparatus.

Install the outdoor unit where operating noise and vibration will not disturb your neighbor and in a well- ventilated area with no obstacle.

ffPotential risk of malfunction.

ffOperating noise may disturb your neighbor.

Make sure that there are no obstacles or covers that block the air conditioner.

Allow sufficient space for air circulation.

ffInsufficient ventilation may result in poor performance.

If the power cable is damaged, the manufacturer or a qualified service technician must replace it.

If a power outage occurs while the air conditioner is working, turn off the power source immediately.

Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency.

Check for damage on delivery. If damaged, do not install the air conditioner and call the place of purchase immediately.

Keep indoor temperatures stable and not extremely cold, especially where there are children, elderly or disabled people.

The packaging material and used batteries of the remote controller (optional) must be disposed of in accordance with the national standards.

The refrigerant used in the air conditioner must be treated as chemical waste. Dispose the refrigerant following national standards.

Have a qualified service technician install the air conditioner and perform a trial operation. Firmly connect the drain hose to the air conditioner for proper water drainage.

Check for damages on the outdoor unit installation pad at least once a year.

ffPotential risk of personal injury or property loss.

ENGLISH

7

Mirage_AP50M0@_IBIM_EN_05323A-02.indd 7

2016-05-19 오후 1:27:10

Image 7
Contents Thank you for purchasing this Samsung product Air ConditionerStrong Turbo/Long Function Features of your new air conditionerLook for Everywhere Contents Important safety symbols and precautions Safety precautionsDo not yank the power cable with hands Ensure no water gets into the air conditioner Do not open the front panel during operation Use a rated circuit breaker onlyFfPotential risk of injury or electric shock FfPotential risk of personal injuryFfInsufficient ventilation may result in poor performance Do not allow children to climb on the air conditionerFfPotential risk of personal injury or property loss FfWearing thick gloves can protect your hands To open the panel Viewing your air conditionerChecking the indoor unit and display Main partsHeater and Purity function is not supported by this model Control panelRemote controller buttons Checking the remote controllerUsing the remote controller Remote controller displayAre in the same space Indoor unit Battery changing timeStoring the remote controller Inserting the batteriesBasic operation Selecting the fan speed Turning on the powerSelecting the operation mode Adjusting the desired temperatureSelecting air flow direction Controller display Setting the On/Off timerWhen the air conditioner is off You cannot set the fan speed when setting the On timerButton When the air conditioner is onWhen the air conditioner is operating in Cool or Heat mode Using the Turbo functionLocking the control panel Using the Long functionUsing the air conditioner with the control panel Cleaning the exterior Cleaning and maintaining the air conditionerCleaning the filter Air filter Maintaining your air conditioner Installation partPeriodical checks Internal protections via the unit control system Have deposited at low temperaturesAppendix TroubleshootingHumidity Operation rangesPersonnel Installing the unitOr accessing its internal components General informationComplete, electric shock or fire may occur Power supply line, fuse or circuit breakerDo not install the air conditioner in following places Make sure that you earth the cablesAccessory parts list Side view Selection of installation placeIndoor unit Top viewOutdoor unit Selecting appropriate location for installation Preparing the installationVentilate Wear protective goggles and mask before spraying Space requirementsSsc *2 Wiring standardElectrical work Cord. Code designation IEC60245 IEC 66 / CENELECH07RN-FUsing 4poles ELCBEarth Leakage Circuit Breaker Indoor and outdoor connection wiringAP50M0 Series AP50M1 Series Using 3poles Elcb and 2poles ElcbConnecting the power terminal Electrical wiringInstallation procedures Installation methodOutdoor unit When using the anchor bolt When using the rubber legTrap FfRadius of curvature R on the oil trap are as follows Check the following list and install an oil trapRefrigerant pipe work Insulating the pipes Oil trapIt may cause explosion and injury Cut the pipe using the pipe cutterConnection of refrigerant piping Flare processing Remove burr on the edge of pipeTightening of connection parts Pipe bendingDrilling a hole in the wall Example Wall installation Corner InstallationDrain hose Fixing the indoor unitBe sure that all valve cocks are closed Air purgeRefrigerant charging How to add refrigerantCheck the stability of the pressure for 10 minutes Check Check and test operationIs grounding properly made? When the outdoor temperature is below zero, do not Pump down procedure When removing the productTest operation Packing and unpacking guide Outdoor unit Tube How to connect your extended power cablesMm of the wire shields of the tube Prepare the following toolsApply heat to the contraction tube to contract it FfMethodMirageAP50M0@IBIMEN05323A-02.indd 2016-05-19 오후 English Questions or COMMENTS?