Appendix
Operation ranges
The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.
MODE | OPERATIONAL TEMPERATURE | INDOOR | IF OUT OF CONDITIONS | ||
INDOOR | OUTDOOR | HUMIDITY | |||
|
| ||||
COOLING |
|
|
| Condensation may occur on the indoor | |
18˚C to 32˚C | 21˚C to 52˚C | 80% or less | unit with risk to have either water blow off | ||
|
|
|
| or drops on the floor. | |
HEATING | 27˚C or less | 0˚C to 24˚C | - | Internal protection triggers and the air | |
conditioner will stop. | |||||
|
|
|
| ||
DRYING |
|
|
| Condensation may occur on the indoor | |
18˚C to 32˚C | 21˚C to 52˚C | - | unit with risk to have either water blow off | ||
|
|
|
| or drops on the floor. |
|
|
| The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below, the heating | |
|
|
| capacity can be reduced depending on the temperature condition. | |
NOTE | ||||
If the cooling operation is used at over 32˚C (indoor temperature), it does not cool at its full capacity. | ||||
|
|
|
26