Samsung AP50M1ANXSG, AP50M0ANXSG manual FfWearing thick gloves can protect your hands

Page 8

Safety precautions

CAUTION

CAUTION SIGNS

When using a wireless remote controller, the distance should not be more than 7 meters from the air conditioner.

If the remote controller is not used for a long period of time, remove the batteries to prevent leakage of electrolyte.

When cleaning the outdoor unit, touch the heat exchanger radiator fins with extreme care.

ffWearing thick gloves can protect your hands.

Make sure that the condensed water dripping from the drain hose runs out properly and safely.

The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety: Young children should be supervised to ensure that they do not play with the appliance.

Inspect the condition, electric connections, pipes and external case of the air conditioner regularly by a qualified service technician.

Do not open doors and windows in the room being cooled during operation unless necessary.

Do not block the air conditioner vents. If objects block the air flow, it may cause unit malfunction or poor performance.

The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry.

Ensure the off-on and protection switches are properly installed.

Do not use the air conditioner if damaged. If problems occur, immediately stop operation and disconnect the plug from the power supply.

If the air conditioner will not be used for an extended period of time (for example, over several months), unplug the power from the wall.

Call the place of purchase or a contact center if repairs are needed.

ffPotential risk of fire or electric shock if disassembly or repairs are attempted by a non-qualified service technician.

8

Mirage_AP50M0@_IBIM_EN_05323A-02.indd 8

2016-05-19 오후 1:27:10

Image 8
Contents Air Conditioner Thank you for purchasing this Samsung productLook for Everywhere Features of your new air conditionerStrong Turbo/Long Function Contents Do not yank the power cable with hands Safety precautionsImportant safety symbols and precautions Ensure no water gets into the air conditioner Use a rated circuit breaker only FfPotential risk of injury or electric shockFfPotential risk of personal injury Do not open the front panel during operationFfPotential risk of personal injury or property loss Do not allow children to climb on the air conditionerFfInsufficient ventilation may result in poor performance FfWearing thick gloves can protect your hands Viewing your air conditioner Checking the indoor unit and displayMain parts To open the panelControl panel Heater and Purity function is not supported by this modelChecking the remote controller Remote controller buttonsAre in the same space Remote controller displayUsing the remote controller Battery changing time Storing the remote controllerInserting the batteries Indoor unitBasic operation Turning on the power Selecting the operation modeAdjusting the desired temperature Selecting the fan speedSelecting air flow direction Setting the On/Off timer When the air conditioner is offYou cannot set the fan speed when setting the On timer Controller displayWhen the air conditioner is on ButtonUsing the Turbo function When the air conditioner is operating in Cool or Heat modeUsing the Long function Locking the control panelUsing the air conditioner with the control panel Cleaning the filter Air filter Cleaning and maintaining the air conditionerCleaning the exterior Periodical checks Installation partMaintaining your air conditioner Have deposited at low temperatures Internal protections via the unit control systemTroubleshooting AppendixOperation ranges HumidityInstalling the unit Or accessing its internal componentsGeneral information PersonnelPower supply line, fuse or circuit breaker Do not install the air conditioner in following placesMake sure that you earth the cables Complete, electric shock or fire may occurAccessory parts list Selection of installation place Indoor unitTop view Side viewOutdoor unit Ventilate Preparing the installationSelecting appropriate location for installation Space requirements Wear protective goggles and mask before sprayingWiring standard Electrical workCord. Code designation IEC60245 IEC 66 / CENELECH07RN-F Ssc *2AP50M0 Series Indoor and outdoor connection wiringUsing 4poles ELCBEarth Leakage Circuit Breaker Using 3poles Elcb and 2poles Elcb AP50M1 SeriesElectrical wiring Connecting the power terminalInstallation method Outdoor unit When using the anchor boltWhen using the rubber leg Installation proceduresTrap Check the following list and install an oil trap Refrigerant pipe work Insulating the pipesOil trap FfRadius of curvature R on the oil trap are as followsCut the pipe using the pipe cutter Connection of refrigerant piping Flare processingRemove burr on the edge of pipe It may cause explosion and injuryDrilling a hole in the wall Pipe bendingTightening of connection parts Wall installation Corner Installation Drain hoseFixing the indoor unit ExampleAir purge Be sure that all valve cocks are closedCheck the stability of the pressure for 10 minutes How to add refrigerantRefrigerant charging Is grounding properly made? Check and test operationCheck Test operation Pump down procedure When removing the productWhen the outdoor temperature is below zero, do not Packing and unpacking guide Outdoor unit How to connect your extended power cables Mm of the wire shields of the tubePrepare the following tools TubeFfMethod Apply heat to the contraction tube to contract itMirageAP50M0@IBIMEN05323A-02.indd 2016-05-19 오후 English Questions or COMMENTS?