Safety precautions

ffDo not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires, explosions or injuries.

ffOur units must be installed in compliance with the spaces indicated in the manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs. The units’ components must be accessible and that can be disassembled in conditions of complete safety either for people or things. For this reason, where it is not observed as indicated into the manual, the cost necessary to reach and repair the unit (in safety, as required by current regulations in force) with slings, trucks, scaffolding or any other means of elevation won’t be considered in-warranty and charged to end user.

Power supply line, fuse or circuit breaker

ffAlways make sure that the power supply is compliant with current safety standards. Always install the air conditioner in compliance with current local safety standards.

ffAlways verify that a suitable grounding connection is available.

ffVerify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines.

ffAlways verify that the cut-off and protection switches are suitably dimensioned.

ffVerify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the manual.

ffAlways verify that electric connections (cable entry, section of leads, protections…) are compliant with the electric specifications and with the instructions provided in the wiring scheme. Always verify that all connections comply with the standards applicable to the installation of air conditioners.

• Make sure that you earth the cables.

CAUTION

-- Do not connect the earth wire to the gas pipe, water pipe, lighting rod or telephone wire. If earthing is not

complete, electric shock or fire may occur.

 

Install the circuit breaker.

-- If the circuit breaker is not installed, electric shock or fire may occur.

Make sure that the condensed water dripping from the drain hose runs out properly and safely.

Install the power cable and communication cable of the indoor and outdoor unit at least 1m away from the electric appliance.

Install the indoor unit away from lighting apparatus using the ballast.

-- If you use the wireless remote controller, reception error may occur due to the ballast of the lighting apparatus.

Do not install the air conditioner in following places.

-- Place where there is mineral oil or arsenic acid. Resin parts flame and the accessories may drop or water may leak. The capacity of the heat exchanger may reduce or the air conditioner may be out of order.

-- The place where corrosive gas such as sulfurous acid gas generates from the vent pipe or air outlet. The copper pipe or connection pipe may corrode and refrigerant may leak.

-- The place where there is a machine that generates electromagnetic waves. The air conditioner may not operate normally due to control system.

-- The place where there is a danger of existing combustible gas, carbon fiber or flammable dust. The place where thinner or gasoline is handled. Gas may leak and it may cause fire.

28

Mirage_AP50M0@_IBIM_EN_05323A-02.indd 28

2016-05-19 오후 1:27:19

Image 28
Contents Air Conditioner Thank you for purchasing this Samsung productStrong Turbo/Long Function Features of your new air conditionerLook for Everywhere Contents Important safety symbols and precautions Safety precautionsDo not yank the power cable with hands Ensure no water gets into the air conditioner Use a rated circuit breaker only FfPotential risk of injury or electric shockFfPotential risk of personal injury Do not open the front panel during operationFfInsufficient ventilation may result in poor performance Do not allow children to climb on the air conditionerFfPotential risk of personal injury or property loss FfWearing thick gloves can protect your hands Viewing your air conditioner Checking the indoor unit and displayMain parts To open the panelControl panel Heater and Purity function is not supported by this modelChecking the remote controller Remote controller buttonsUsing the remote controller Remote controller displayAre in the same space Battery changing time Storing the remote controllerInserting the batteries Indoor unitBasic operation Turning on the power Selecting the operation modeAdjusting the desired temperature Selecting the fan speedSelecting air flow direction Setting the On/Off timer When the air conditioner is offYou cannot set the fan speed when setting the On timer Controller displayWhen the air conditioner is on ButtonUsing the Turbo function When the air conditioner is operating in Cool or Heat modeUsing the Long function Locking the control panelUsing the air conditioner with the control panel Cleaning the exterior Cleaning and maintaining the air conditionerCleaning the filter Air filter Maintaining your air conditioner Installation partPeriodical checks Have deposited at low temperatures Internal protections via the unit control systemTroubleshooting AppendixOperation ranges HumidityInstalling the unit Or accessing its internal componentsGeneral information PersonnelPower supply line, fuse or circuit breaker Do not install the air conditioner in following placesMake sure that you earth the cables Complete, electric shock or fire may occurAccessory parts list Selection of installation place Indoor unitTop view Side viewOutdoor unit Selecting appropriate location for installation Preparing the installationVentilate Space requirements Wear protective goggles and mask before sprayingWiring standard Electrical workCord. Code designation IEC60245 IEC 66 / CENELECH07RN-F Ssc *2Using 4poles ELCBEarth Leakage Circuit Breaker Indoor and outdoor connection wiringAP50M0 Series Using 3poles Elcb and 2poles Elcb AP50M1 SeriesElectrical wiring Connecting the power terminalInstallation method Outdoor unit When using the anchor boltWhen using the rubber leg Installation proceduresTrap Check the following list and install an oil trap Refrigerant pipe work Insulating the pipesOil trap FfRadius of curvature R on the oil trap are as followsCut the pipe using the pipe cutter Connection of refrigerant piping Flare processingRemove burr on the edge of pipe It may cause explosion and injuryTightening of connection parts Pipe bendingDrilling a hole in the wall Wall installation Corner Installation Drain hoseFixing the indoor unit ExampleAir purge Be sure that all valve cocks are closedRefrigerant charging How to add refrigerantCheck the stability of the pressure for 10 minutes Check Check and test operationIs grounding properly made? When the outdoor temperature is below zero, do not Pump down procedure When removing the productTest operation Packing and unpacking guide Outdoor unit How to connect your extended power cables Mm of the wire shields of the tubePrepare the following tools TubeFfMethod Apply heat to the contraction tube to contract itMirageAP50M0@IBIMEN05323A-02.indd 2016-05-19 오후 English Questions or COMMENTS?