Samsung AF0AKV3SAEENSG manual Power supply and wire specification

Page 57

Power supply and wire specification

 

Model name

 

 

 

 

Indoor unit

 

Outdoor unit

 

 

 

 

 

AF80KV3SAEEN

 

AF80KV3SAEEX

 

 

 

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

Product

 

 

220 - 240 V~ 50 Hz

380 - 415 V 3N~ 50 Hz

Power

Cooling

 

 

 

T1

 

W

520 W

 

8000 W

 

 

 

T3

 

 

520 W

 

7600 W

consumption

 

 

 

 

 

 

 

 

Heating

 

 

-

 

 

 

W

-

 

-

Operationg

Cooling

 

 

 

T1

 

A

2.3 A

 

12.5 A

 

 

 

T3

 

 

2.3 A

 

11.9 A

current

 

 

 

 

 

 

 

 

Heating

 

 

-

 

 

 

A

-

 

-

 

 

 

 

 

 

 

Capacity of

 

Product

 

 

 

A

30

 

circuit breaker

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thickness of ground wire

 

 

 

mm2

4.0

 

Indoor and outdoor unit

 

 

 

mm2

0.75~1.5

 

communication wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

 

At least equal to H05RN-F

At least equal to H07RN-F

 

 

 

 

 

 

Below

mm2

2.5 (Should be purchased

2.5 (Should be purchased

Power wire

Product

 

 

20m

 

separately)

 

separately)

 

 

20m or

mm2

4.0 (Should be purchased

4.0

(Should be purchased

 

 

 

 

 

 

 

 

 

 

 

 

 

over

 

separately)

 

separately)

 

Model name

 

 

 

 

Indoor unit

 

Outdoor unit

 

 

 

 

 

AF0AKV3SAEEN

 

AF0AKV3SAEEX

 

 

 

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

Product

 

220 - 240 V~ 50 Hz

380 - 415 V 3N~ 50 Hz

 

 

 

Cooling

 

 

T1

W

560 W

 

11 900 W

Power consumption

 

 

 

T3

560 W

 

9900 W

 

 

 

Heating

 

 

-

W

-

 

-

 

 

 

Cooling

 

 

T1

A

2.5 A

 

18.3 A

Operationg current

 

 

 

T3

2.5 A

 

15.4 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

 

 

-

A

-

 

-

Capacity of circuit

 

 

 

Product

 

A

30

 

breaker

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thickness of ground wire

 

 

 

mm2

4.0

 

Indoor and outdoor unit

 

 

 

mm2

0.75~1.5

 

communication wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

At least equal to H05RN-F

At least equal to H07RN-F

 

 

 

 

 

 

 

Below

mm2

2.5 (Should be purchased

4.0 (Should be purchased

Power wire

Product

 

20m

separately)

 

separately)

 

 

 

20m

mm2

4.0 (Should be purchased

6.0

(Should be purchased

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or over

 

separately)

 

separately)

INSTALLATION PARTS

English 57

Image 57
Contents Air conditioner Contents Safety precautions For Installation Using Parts For Power Supply Using Parts Safety precautions Using Parts For Cleaning Checking the auxiliary power switch Using outdoor unitOperational temperature and humidity range Checking before useViewing the parts Main partsTo open the panel Control panel and the display Locking the control panelUsing the air conditioner with the control panel Remote controller button Checking the remote controllerInserting the batteries Remote controller displayStoring the remote controller Battery changing timeCool Basic operationAuto DryAdjusting the air flow direction Using the Turbo function Setting the On timer Timer functionSetting the Off timer Cleaning and maintaining the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Cleaning the air filter Maintaining the air conditioner Periodical checks Problem Solution TroubleshootingTroubleshooting General information Power supply line, fuse or circuit breaker Installing the unitInstallation Parts Accessory parts list Preparation for installation Indoor  outdoor unit type and combinationMoving the outdoor unit Indoor unit Deciding on where to install the productOutdoor unit Deciding on where to install the product Space requirements Installation location 2000 Or more 300 or More 1500 or Or 600 or more more Or more Pipe length between the indoor and the outdoor unit Less than 30mDrilling a hole in the wall Installing Outdoor unit Installing indoor unitBase ground contruction Installation Parts Installation Parts Refrigerant piping work Connecting the pipesFix the pipe on Indoor Pipe connection Selecting refrigerant pipeTemper grade and minimum thickness of the refrigerant pipe Storing refrigerant pipe Cutting or flaring the pipes Direction of the pipe when brazingTightening flare connection part Pipe bending Connecting the drain hoseInsulating refrigerant pipe Selecting the insulator of the refrigerant pipeAllowable refrigerant pipe length Refrigerant chargingHow to add refrigerant Electrical work Wiring workPower supply and wire specification Phase 4 wires Power wiring diagramEarth Connecting power and communication cableSelecting solderless ring terminal Connecting the power terminal Connect the ring terminal Fixing the power cableGrounding work Installing grounding wire Wiring work Gas leak test and vacuum drying Check lists after completing the installation Testing operations SEG2 SEG3 SEG4 On on Check electrical connection and setting E441 IPM Installationparts How to connect your extended power cables Installation Parts Packing and unpacking guide Packing the indoor unit Unpacking the indoor unitPacking the outdoor unit Unpacking the outdoor unitCooling Questions or COMMENTS?