Samsung AF0AKV3SAEENSG manual Connecting the power terminal

Page 61

Connecting the power terminal

Connect the cables to the terminal board with solderless ring terminals.

Only use the certified and rated cables and make sure to firmly connect them without applying any external force to the terminal.

Connect with a driver and a wrench that are able to apply the rated torque to the screws.

If the terminal is loose, fire can occur due to arc heat generation. However, If the terminal is connected too firmly, the terminal may get damaged.

Screw

Tightening torque (kgf∙cm)

M3

5.0

~ 7.5

M3.5

8.0 ~ 12.0

M4

12.0

~ 18.0

M5

20.0

~ 30.0

M6

25.0

~ 37.5

CAUTION

When removing the outer sheath of the power supply cable, be careful not to scratch the inner sheath of the cable.

Make sure that more than 20mm of the outer sheath of the indoor unit power supply cable and communication cable are inside the electrical component box.

Install the communication cable separately from power cable and other communication cables.

INSTALLATION PARTS

English 61

Image 61
Contents Air conditioner Contents Safety precautions For Installation Using Parts For Power Supply Using Parts Safety precautions Using Parts For Cleaning Checking the auxiliary power switch Using outdoor unitOperational temperature and humidity range Checking before useMain parts Viewing the partsTo open the panel Control panel and the display Locking the control panelUsing the air conditioner with the control panel Remote controller button Checking the remote controllerInserting the batteries Remote controller displayStoring the remote controller Battery changing timeCool Basic operationAuto DryAdjusting the air flow direction Using the Turbo function Setting the On timer Timer functionSetting the Off timer Cleaning the indoor unit Cleaning and maintaining the air conditionerCleaning the outdoor unit heat exchanger Cleaning the air filter Maintaining the air conditioner Periodical checks Problem Solution TroubleshootingTroubleshooting General information Power supply line, fuse or circuit breaker Installing the unitInstallation Parts Accessory parts list Indoor  outdoor unit type and combination Preparation for installationMoving the outdoor unit Indoor unit Deciding on where to install the productOutdoor unit Deciding on where to install the product Space requirements Installation location 2000 Or more 300 or More 1500 or Or 600 or more more Or more Less than 30m Pipe length between the indoor and the outdoor unitDrilling a hole in the wall Installing Outdoor unit Installing indoor unitBase ground contruction Installation Parts Installation Parts Refrigerant piping work Connecting the pipesFix the pipe on Indoor Selecting refrigerant pipe Pipe connectionTemper grade and minimum thickness of the refrigerant pipe Storing refrigerant pipe Cutting or flaring the pipes Direction of the pipe when brazingTightening flare connection part Pipe bending Connecting the drain hoseInsulating refrigerant pipe Selecting the insulator of the refrigerant pipeAllowable refrigerant pipe length Refrigerant chargingHow to add refrigerant Electrical work Wiring workPower supply and wire specification Phase 4 wires Power wiring diagramEarth Connecting power and communication cableSelecting solderless ring terminal Connecting the power terminal Connect the ring terminal Fixing the power cableGrounding work Installing grounding wire Wiring work Gas leak test and vacuum drying Check lists after completing the installation Testing operations SEG2 SEG3 SEG4 On on Check electrical connection and setting E441 IPM Installationparts How to connect your extended power cables Installation Parts Packing and unpacking guide Packing the indoor unit Unpacking the indoor unitPacking the outdoor unit Unpacking the outdoor unitCooling Questions or COMMENTS?