Napoleon Fireplaces BGD36CFNTR, BGD36CFGN, BGD42CFN manual Formula 2 HT + VT 40 feet Example =5 ft

Page 14

14

BGD36CF(G) TOP OR REAR EXIT VERTICAL TERMINATION

when (HT) < (VT)

Simple venting confi guration (only two 90° elbows)

FIGURE 29

REQUIRED

VERTICAL

RISE IN

FEET VT

HORIZONTAL VENT RUN PLUS

OFFSET IN FEET HT

The shaded area within the lines represents acceptable values for HT and VT .

See graph to determine the required vertical rise VT for the required horizontal run HT

For vent confi gurations requiring more than zero 90° elbow (top exit) or one 90° elbow (rear exit), the following formulas apply:

Formula 1: HT < VT

Formula 2: HT + VT < 40 feet

Example 6:

90° V2

FIGURE 30

H2

H1 V1

90°

V1=5 ft

90°

 

V2=10 ft

VT=V1 + V2 = 5 + 10 = 15 ft H1=3 ft

H2=2.5 ft

HR=H1 + H2 = 3 + 2.5 = 5.5 ft HO=.03 (three 90° elbows - 90°)

=.03(90 + 90 + 90 - 90) = 5.4 ft

HT=HR + HO = 5.5 + 5.4 = 10.9 ft

HT + VT= 10.9 + 15 = 25.9 ft

Formula 1: HT < VT 10.9 < 15

Formula 2: HT + VT < 40 feet 25.9 < 40

Since both formulas are met, this vent confi guration is ac- ceptable.

when (HT) > (VT)

Simple venting confi gurations

FIGURE 31

See graph to determine

the required vertical rise VT for the required horizontal

run HT.

MAXIMUM

VERTICAL

RISE IN

FEET

VT

HORIZONTAL VENT RUN PLUS OFFSET IN

FEET HT

The shaded area within the lines represents acceptable values for HT and VT .

For vent confi gurations requiring more than two 90° elbows (top exit) or one 90° elbow (rear exit), the following formulas apply:

Formula 1: HT < 3VT

Formula 2: HT + VT < 40 feet

Example 7:

90°

90°

V3

V1

V2 H2

 

 

H1

90°

 

90°

FIGURE 32

V1 = 2 ft V2 = 1 ft V3 = 1.5 ft

VT = V1 + V2 + V3 = 2 + 1 + 1.5 = 4.5 ft H1 = 6 ft

H2 = 2 ft

HR = H1 + H2 = 6 + 2 = 8 ft

HO = .03 (four 90° elbows - 90°)

= .03(90 + 90 + 90 + 90 - 90) = 8.1 ft

HT = HR + HO = 8 + 8.1 = 16.1 ft

HT + VT = 16.1 + 4.5 = 20.6 ft

Formula 1: HT < 3VT

3VT = 3 x 4.5 = 13.5 ft

Since this formula is not met, this vent confi guration is unac- ceptable.

Formula 2: HT + VT < 40 feet 20.6 < 40

Since only formula 2 is met, this vent confi guration is unacceptable and a new fi replace location or vent confi guration will need to be established to satisfy both formulas.

W415-0661 / C / 02.20.08

Image 14
Contents Installation Operating Instructions Table of Contents W415-0661 / C Care of Glass and Plated Parts General InstructionsGeneral Information For example in Massachusetts State38 1/2 Unit DimensionsInstallation Overview 24 1/4Venting Venting LengthsW415-0661 / C Typical Minimum and Maximum Vent Lengths See Venting SectionPeriscope Termination Special Vent InstallationsTOP Exit Installation Rear Exit Installation Corner TerminationHorizontal Termination Vertical Termination Venting Application Flow ChartFireplace Vent Exit Rear Exit TOP Exit Definitions When HT VTBGD36CFG TOP Exit / Horizontal Termination Elbow Vent Length ValuesExample Formula 2 HT + VT 24.75 feetFormula 1 HT 3.5VT Formula 2 HT + VT 24.75 feet Example BGD36CFG Rear Exit / Horizontal TerminationFormula 1 HT VT Formula 2 HT + VT 40 feet Formula 2 HT + VT 40 feet Example =5 ft Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleBGD36CFG TOP or Rear Exit Vertical Termination BGD42CF Horizontal Termination = HR + HO = 5.5 + 5.4 = 10.9 ft BGD42CF Vertical Termination= .03 45 + 90 + 90 +90 135 = 5.4 ft HT + VTFormula 1 HT 3VT Formula 2 HT + VT 40 feet Example BGD36CFG PRE-INSTALLATION Preparation Installation Wall and Ceiling ProtectionSpace around the pipe. Nail Vertical InstallationBGD42CF only Adjustable Firestop Installation Headers between the joist forUsing Flexible Vent Components Horizontal AIR Terminal InstallationExtended Horizontal and Corner AIR Terminal Installation Using Rigid Vent ComponentsVertical Venting Installation Optional Wall Switch Installation Excluding BGD36CFG GAS InstallationMobile Home Installation Restricting Vertical VentsCavity Installing StandoffsFraming BGD36CFG BGD42CF 46 1/2BGD36CFG Minimum Mantel and Enclosure Clearances Convex Concave Clean Face Surround Minimum Enclosure ClearancesFinished Floor Installation 37 3 Hearth InstallationOptional Clean Face Trim KIT Installation BGD42CF Minimum Mantel and Enclosure Clearances GLASS/DOOR Replacement LOG PlacementDoor Installation / Removal Finishing BGD36CF FinishingGrate Door Trim LOG PlacementGrate Installation BGD36CFG Finishing Installing the Blower Optional Blower InstallationBGD42CF Accessing the Blower BGD36CFG Accessing the Blower FigureGD36 Thermostatic Sensor Control Electrical Code in the United StatesBGD36CFG Burner Switch / Wiring Diagram Gauge FeetBGD36CFG Light Switch / Wiring Diagram Receptacle Wiring Diagram To Turn OFF GAS Operation BGD36CF & BGD42CFLighting Instructions Operation BGD36CFG MaintenanceFor Your Safety Read Before Operating Operating InstructionsBGD36CFG Venturi Adjustment AdjustmentsVenturi Adjustment Pilot Burner Adjustment Excluding BGD36CFGBGD42CF Flame Characteristics Flame AdjustmentBGD36CF Flame Characteristics BGD36CFG Flame CharacteristicsCommon Replacements BGD36CFG ReplacementsBGD42CF Replacements W415-0661 / C BGD36CFG Trouble Shooting Guide Symptom Problem Test SolutionNot turn on Module or Valve Pilot lights Wiring / ConnectionRight order Ing, touch black lead to ground valve bodyWhich will not allow Pilot burner to be Gas valve hasAn interlock device Lit until the thermoModel BGD42CF only