Napoleon Fireplaces BGD42CFN, BGD36CFGN, BGD36CFNTR manual BGD42CF Replacements

Page 43

43

BGD42CF REPLACEMENTS

BGD42CF COMPONENTS:

89

W455-0019

#43 NATURAL GAS ORIFICE

89

W455-0003

#54 PROPANE GAS ORIFICE

90

W010-0864

PAN BURNER

91

GL-641

LOG SET

92

W135-0198

BACK LOG (#1)

93W135-0201 LEFT CROSSOVER LOG (#4)

94W135-0203 RIGHT CROSSOVER LOG (#5)

95W135-0199 SMALL LEFT LOG (#2)

96W135-0200 SMALL RIGHT LOG (#3)

97W010-1819 BLACK DOOR C/W GLASS

98W010-1778 FIRESTOP SPACER

99*

W500-0205

RESTRICTOR PLATE

 

 

100

W585-0138

VENT HEAT SHIELD, TOP PIECE

 

100

W655-0222

VENT HEAT SHIELD, BOTTOM PIECE

101

W185-0020

GRATE

 

 

102*

W550-0002

CHARCOAL LUMPS

 

 

 

 

 

BGD42CF FLEXIBLE VENT KITS:

 

GD420 (5 FT)

 

 

 

103*

W730-0010

5" FLEXIBLE VENT PIPE - (5.5 FT) C/W SPACERS

104*

W730-0012

8" FLEXIBLE VENT PIPE - (5.5 FT)

 

 

GD430 (10 FT)

 

 

105*

W730-0011

5" FLEXIBLE VENT PIPE -(11.5 FT)

106*

W730-0013

8" FLEXIBLE VENT PIPE -(11.5 FT) C/W SPACERS

107*

W010-0810

WALL SUPPORT ASSEMBLY

 

 

 

 

BGD42CF TERMINAL KITS:

108

PERISCOPE

 

-

GD401

109

WALL TERMINAL KIT

-

GD422

 

 

 

BGD42CF ROOF TERMINAL KITS:

110*

1/12 TO 7/12 PITCH

-

GD410

111*

8/12 TO 12/12 PITCH

-

GD411

112*

FLAT ROOF

 

-

GD412

113

W490-0074

5/8 INNER/OUTER SLEEVE

 

114

W670-0007

5/8 TERMINAL

 

 

115

W170-0086

STORM COLLAR

 

 

116

W010-0453

ROOF SUPPORT

 

 

117

W263-0065 /

ROOF FLASHING

 

 

 

W263-0066 /

 

 

 

 

W263-0055

 

 

 

 

 

 

BGD42CF ACCESSORIES:

118*

W175-0166

5" COUPLER

 

 

119*

W175-0002

8" COUPLER

 

 

120*

W500-0206

TERMINAL EXTENSION PLATE

 

121

GD-501

HEAT GUARD

 

 

122*

W585-0096

SOFFIT HEAT SHIELD

 

 

123*

W010-0810

WALL SUPPORT ASSEMBLY

 

124*

W175-0170

DURA-VENT ZERO CLEARANCE ADAPTOR

125

W170-0086

VENT PIPE COLLAR

 

 

126

W585-0092

VENT PIPE SHIELD

 

 

127*

W175-0211

CONVERSION KIT - NG TO LP

 

128*

W175-0248

CONVERSION KIT - LP TO NG

 

 

129*

S42WN

WAVE SURROUND - BROWN

 

 

129*

S42WP

WAVE SURROUND - PEWTER

 

129*

S42CCN

CONCAVE SURROUND - BROWN

 

129*

S42CCP

CONCAVE SURROUND - PEWTER

 

129*

S42CVN

CONVEX SURROUND - BROWN

 

129*

S42CVP

CONVEX SURROUND - PEWTER

 

130*

CFT42W

UPPER TRIM FOR WAVE SURROUND

130*

CFT42CC

UPPER TRIM FOR CONCAVE SURROUND

130*

CFT42CV

UPPER TRIM FOR CONVEX SURROUND

W415-0661 / C / 02.20.08

Image 43
Contents Installation Operating Instructions Table of Contents W415-0661 / C For example in Massachusetts State General InstructionsGeneral Information Care of Glass and Plated Parts24 1/4 Unit DimensionsInstallation Overview 38 1/2Venting Lengths VentingW415-0661 / C See Venting Section Typical Minimum and Maximum Vent LengthsCorner Termination Special Vent InstallationsTOP Exit Installation Rear Exit Installation Periscope TerminationFireplace Vent Exit Rear Exit TOP Exit Venting Application Flow ChartHorizontal Termination Vertical Termination Elbow Vent Length Values When HT VTBGD36CFG TOP Exit / Horizontal Termination DefinitionsFormula 2 HT + VT 24.75 feet ExampleFormula 1 HT VT Formula 2 HT + VT 40 feet BGD36CFG Rear Exit / Horizontal TerminationFormula 1 HT 3.5VT Formula 2 HT + VT 24.75 feet Example Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Formula 2 HT + VT 40 feet Example =5 ftBGD36CFG TOP or Rear Exit Vertical Termination BGD42CF Horizontal Termination HT + VT BGD42CF Vertical Termination= .03 45 + 90 + 90 +90 135 = 5.4 ft = HR + HO = 5.5 + 5.4 = 10.9 ftFormula 1 HT 3VT Formula 2 HT + VT 40 feet Example Installation Wall and Ceiling Protection BGD36CFG PRE-INSTALLATION PreparationHeaders between the joist for Vertical InstallationBGD42CF only Adjustable Firestop Installation Space around the pipe. NailHorizontal AIR Terminal Installation Using Flexible Vent ComponentsVertical Venting Installation Using Rigid Vent ComponentsExtended Horizontal and Corner AIR Terminal Installation Restricting Vertical Vents GAS InstallationMobile Home Installation Optional Wall Switch Installation Excluding BGD36CFGFraming Installing StandoffsCavity 46 1/2 BGD36CFG BGD42CFBGD36CFG Minimum Mantel and Enclosure Clearances Finished Floor Installation Clean Face Surround Minimum Enclosure ClearancesConvex Concave Optional Clean Face Trim KIT Installation Hearth Installation37 3 BGD42CF Minimum Mantel and Enclosure Clearances Finishing BGD36CF Finishing LOG PlacementDoor Installation / Removal GLASS/DOOR ReplacementGrate Installation Door Trim LOG PlacementGrate BGD36CFG Finishing BGD36CFG Accessing the Blower Figure Optional Blower InstallationBGD42CF Accessing the Blower Installing the BlowerElectrical Code in the United States GD36 Thermostatic Sensor ControlGauge Feet BGD36CFG Burner Switch / Wiring DiagramBGD36CFG Light Switch / Wiring Diagram Receptacle Wiring Diagram Lighting Instructions Operation BGD36CF & BGD42CFTo Turn OFF GAS Operating Instructions MaintenanceFor Your Safety Read Before Operating Operation BGD36CFGPilot Burner Adjustment Excluding BGD36CFG AdjustmentsVenturi Adjustment BGD36CFG Venturi AdjustmentBGD36CFG Flame Characteristics Flame AdjustmentBGD36CF Flame Characteristics BGD42CF Flame CharacteristicsBGD36CFG Replacements Common ReplacementsBGD42CF Replacements W415-0661 / C Symptom Problem Test Solution BGD36CFG Trouble Shooting GuideIng, touch black lead to ground valve body Pilot lights Wiring / ConnectionRight order Not turn on Module or ValveLit until the thermo Gas valve hasAn interlock device Which will not allow Pilot burner to beModel BGD42CF only