Napoleon Fireplaces BGD36CFGN manual Finishing BGD36CF Finishing, BGD42CF Finishing, LOG Placement

Page 30
DOOR LATCH

30

FINISHING

BGD36CF FINISHING

LOG PLACEMENT

PHAZERTM logs and glowing embers exclusive to Napoleon® Fire- places, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect.

Log colours may vary. During the initial use of the fi replace, Log colours may vary. During the initial use of the fi replace the colours will become more uniform as colour pigments burn in during the heat activated curing process.

FIGURE 93

SIDEVIEW

1.Place the back log (#1) onto the log support tray and in front of the tabs. The tabs maintain an air space between the log and fi rebox back to facilitate combustion air fl ow. Ensure that the back of the log rests against the brackets on the back wall of the fi rebox.

FIGURE 98

5.Place the bottom of the right crossover log (#6) against the right fi rebox side and pulled forward to the grate. The top of the log should rest in the pocket provided on the center log (#5).

BGD36CF(G) GLASS/DOOR REPLACEMENT

1. Place the door frame face down care-

FIGURE99

ful not to scratch the paint.

 

2. Center the gasketed glass inside the door frame with the thick side of the gasket fac- ing up.

3. Bend the glass retainers lo- cated along the edge of the door frame over the gasket holding the glass in place. Careful not to break the glass.

BGD42CF FINISHING

DOOR INSTALLATION / REMOVAL

TAB

FIGURE 94

FIGURE 95

2.Move the two small logs (#2 & #3) into position, lining up the studs located on the burner with the holes on the bottom of the logs. Ensure that the small logs sit fl at on the burner.

FIGURE 96

Open the Valve Access Door. While holding the door securely, release the 4 latches along the top of the door.

Tilt the door forward and lift off of the

two brackets at the bottom of the door.

When replacing the door, rest the door on the brackets ensuring that lip of the brackets rest in the groove in the bottom edge of the door. Push the door backward into place and secure with the 4 latches.

FIGURE 100

DOOR BRACKET

3.Place the bottom of the left crossover log (#4) against the left

rebox side and pulled forward to the grate.

The top of the log should rest in the pocket on the back log.

FIGURE 97

4.Position the base end of the center log (#5) against the middle grate post with the other end of the log resting in the pocket of the left crossover log.

REMOVING THE VALVE ACCESS DOOR

1.The valve access door rotates on the pins attached to the side frame. Lift the valve access door off the pins to operate

the main glass door.

FIGURE 101

GLASS/DOOR REPLACEMENT

Only available as an assembly complete with frame W010-0770. Glass not available seperately.

W415-0661 / C / 02.20.08

Image 30
Contents Installation Operating Instructions Table of Contents W415-0661 / C Care of Glass and Plated Parts General InstructionsGeneral Information For example in Massachusetts State38 1/2 Unit DimensionsInstallation Overview 24 1/4Venting Venting LengthsW415-0661 / C Typical Minimum and Maximum Vent Lengths See Venting SectionPeriscope Termination Special Vent InstallationsTOP Exit Installation Rear Exit Installation Corner TerminationVenting Application Flow Chart Fireplace Vent Exit Rear Exit TOP ExitHorizontal Termination Vertical Termination Definitions When HT VTBGD36CFG TOP Exit / Horizontal Termination Elbow Vent Length ValuesExample Formula 2 HT + VT 24.75 feetBGD36CFG Rear Exit / Horizontal Termination Formula 1 HT VT Formula 2 HT + VT 40 feetFormula 1 HT 3.5VT Formula 2 HT + VT 24.75 feet Example Formula 2 HT + VT 40 feet Example =5 ft Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleBGD36CFG TOP or Rear Exit Vertical Termination BGD42CF Horizontal Termination = HR + HO = 5.5 + 5.4 = 10.9 ft BGD42CF Vertical Termination= .03 45 + 90 + 90 +90 135 = 5.4 ft HT + VTFormula 1 HT 3VT Formula 2 HT + VT 40 feet Example BGD36CFG PRE-INSTALLATION Preparation Installation Wall and Ceiling ProtectionSpace around the pipe. Nail Vertical InstallationBGD42CF only Adjustable Firestop Installation Headers between the joist forUsing Flexible Vent Components Horizontal AIR Terminal InstallationUsing Rigid Vent Components Vertical Venting InstallationExtended Horizontal and Corner AIR Terminal Installation Optional Wall Switch Installation Excluding BGD36CFG GAS InstallationMobile Home Installation Restricting Vertical VentsInstalling Standoffs FramingCavity BGD36CFG BGD42CF 46 1/2BGD36CFG Minimum Mantel and Enclosure Clearances Clean Face Surround Minimum Enclosure Clearances Finished Floor InstallationConvex Concave Hearth Installation Optional Clean Face Trim KIT Installation37 3 BGD42CF Minimum Mantel and Enclosure Clearances GLASS/DOOR Replacement LOG PlacementDoor Installation / Removal Finishing BGD36CF FinishingDoor Trim LOG Placement Grate InstallationGrate BGD36CFG Finishing Installing the Blower Optional Blower InstallationBGD42CF Accessing the Blower BGD36CFG Accessing the Blower FigureGD36 Thermostatic Sensor Control Electrical Code in the United StatesBGD36CFG Burner Switch / Wiring Diagram Gauge FeetBGD36CFG Light Switch / Wiring Diagram Receptacle Wiring Diagram Operation BGD36CF & BGD42CF Lighting InstructionsTo Turn OFF GAS Operation BGD36CFG MaintenanceFor Your Safety Read Before Operating Operating InstructionsBGD36CFG Venturi Adjustment AdjustmentsVenturi Adjustment Pilot Burner Adjustment Excluding BGD36CFGBGD42CF Flame Characteristics Flame AdjustmentBGD36CF Flame Characteristics BGD36CFG Flame CharacteristicsCommon Replacements BGD36CFG ReplacementsBGD42CF Replacements W415-0661 / C BGD36CFG Trouble Shooting Guide Symptom Problem Test SolutionNot turn on Module or Valve Pilot lights Wiring / ConnectionRight order Ing, touch black lead to ground valve bodyWhich will not allow Pilot burner to be Gas valve hasAn interlock device Lit until the thermoModel BGD42CF only