BGD36CF(G) MINIMUM MANTEL AND ENCLOSURE CLEARANCES

Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed.

FIGURE 77

FIGURE 80

The fi replace requires a minimum enclosure height of 38 1/2“ (REAR VENT) 49" (TOP VENT). For temperature requirements, the enclosure space around and above the fi replace must be left unobstructed.

FIGURE 78

FIGURE 79

*If this unit is installed fl ush to the fi nishing material and optional clean face surround is to be installed then a minimum of 6 1/2" of cement board or non-combustible equivalent must be used on the top only of the front face. See Figure 80.

**See Venting Section

W415-0661 / C / 02.20.08

Image 26
Contents Installation Operating Instructions Table of Contents W415-0661 / C Care of Glass and Plated Parts General InstructionsGeneral Information For example in Massachusetts State38 1/2 Unit DimensionsInstallation Overview 24 1/4Venting Venting LengthsW415-0661 / C Typical Minimum and Maximum Vent Lengths See Venting SectionPeriscope Termination Special Vent InstallationsTOP Exit Installation Rear Exit Installation Corner TerminationHorizontal Termination Vertical Termination Venting Application Flow ChartFireplace Vent Exit Rear Exit TOP Exit Definitions When HT VTBGD36CFG TOP Exit / Horizontal Termination Elbow Vent Length ValuesExample Formula 2 HT + VT 24.75 feetFormula 1 HT 3.5VT Formula 2 HT + VT 24.75 feet Example BGD36CFG Rear Exit / Horizontal TerminationFormula 1 HT VT Formula 2 HT + VT 40 feet Formula 2 HT + VT 40 feet Example =5 ft Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleBGD36CFG TOP or Rear Exit Vertical Termination BGD42CF Horizontal Termination = HR + HO = 5.5 + 5.4 = 10.9 ft BGD42CF Vertical Termination= .03 45 + 90 + 90 +90 135 = 5.4 ft HT + VTFormula 1 HT 3VT Formula 2 HT + VT 40 feet Example BGD36CFG PRE-INSTALLATION Preparation Installation Wall and Ceiling ProtectionSpace around the pipe. Nail Vertical InstallationBGD42CF only Adjustable Firestop Installation Headers between the joist forUsing Flexible Vent Components Horizontal AIR Terminal InstallationExtended Horizontal and Corner AIR Terminal Installation Using Rigid Vent ComponentsVertical Venting Installation Optional Wall Switch Installation Excluding BGD36CFG GAS InstallationMobile Home Installation Restricting Vertical VentsCavity Installing StandoffsFraming BGD36CFG BGD42CF 46 1/2BGD36CFG Minimum Mantel and Enclosure Clearances Convex Concave Clean Face Surround Minimum Enclosure ClearancesFinished Floor Installation 37 3 Hearth InstallationOptional Clean Face Trim KIT Installation BGD42CF Minimum Mantel and Enclosure Clearances GLASS/DOOR Replacement LOG PlacementDoor Installation / Removal Finishing BGD36CF FinishingGrate Door Trim LOG PlacementGrate Installation BGD36CFG Finishing Installing the Blower Optional Blower InstallationBGD42CF Accessing the Blower BGD36CFG Accessing the Blower FigureGD36 Thermostatic Sensor Control Electrical Code in the United StatesBGD36CFG Burner Switch / Wiring Diagram Gauge FeetBGD36CFG Light Switch / Wiring Diagram Receptacle Wiring Diagram To Turn OFF GAS Operation BGD36CF & BGD42CFLighting Instructions Operation BGD36CFG MaintenanceFor Your Safety Read Before Operating Operating InstructionsBGD36CFG Venturi Adjustment AdjustmentsVenturi Adjustment Pilot Burner Adjustment Excluding BGD36CFGBGD42CF Flame Characteristics Flame AdjustmentBGD36CF Flame Characteristics BGD36CFG Flame CharacteristicsCommon Replacements BGD36CFG ReplacementsBGD42CF Replacements W415-0661 / C BGD36CFG Trouble Shooting Guide Symptom Problem Test SolutionNot turn on Module or Valve Pilot lights Wiring / ConnectionRight order Ing, touch black lead to ground valve bodyWhich will not allow Pilot burner to be Gas valve hasAn interlock device Lit until the thermoModel BGD42CF only