Napoleon Fireplaces BGD42CFN, BGD36CFGN, BGD36CFNTR Adjustments, BGD36CFG Venturi Adjustment

Page 40

40

ADJUSTMENTS

PILOT BURNER ADJUSTMENT

EXCLUDING BGD36CFG

Adjust the pilot screw to provide prop- erly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow.

FIGURE 128

FIGURE 129

VENTURI ADJUSTMENT

Both fi replace models have air shutters that have been factory set open according to the chart below:

BGD36CF BGD36CFG BGD42CF

NG

1/16"

0

1/4"

 

 

 

 

LP

1/4"

0

7/16"

These settings are for (maximum) horizontal termination. Adjust- ment may be required depending on fuel type, vent confi guration and altitude.

Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame colour to be established.

Air shutter adjustment must only be done by a qualified

installer!

FIGURE 130

BGD36CFG VENTURI ADJUSTMENT

FIGURE 132

The alternate access is to remove the glass, glass ember tray and burner from the fi replace and then adjust the air shutter.

FIGURE 133

!WARNING

The front of the fireplace becomes very hot during operation. Let the fireplace cool completely before conducting service.

NOTE: When removing the glass ember tray make sure the glass embers are away from the center of the screen, exposing the burner, before lifting glass ember tray out.

When replacing burner, absolutely no glass can be in cup surrounding the orifice. HINT: If glass falls into cup and surrounds the orifice, insert a clean bag into a vacuum cleaner and vacuum out glass embers or replacement glass embers can be ordered from Wolf Steel Ltd.

V E N T U R I

FIGURE 131

To access the air shutter, remove the control panel, remove the two screws that secure the cover to the air housing, loosen the set screw and adjust air shutter position.

W415-0661 / C / 02.20.08

Image 40
Contents Installation Operating Instructions Table of Contents W415-0661 / C General Instructions General InformationCare of Glass and Plated Parts For example in Massachusetts StateUnit Dimensions Installation Overview38 1/2 24 1/4Venting Venting LengthsW415-0661 / C Typical Minimum and Maximum Vent Lengths See Venting SectionSpecial Vent Installations TOP Exit Installation Rear Exit InstallationPeriscope Termination Corner TerminationFireplace Vent Exit Rear Exit TOP Exit Venting Application Flow ChartHorizontal Termination Vertical Termination When HT VT BGD36CFG TOP Exit / Horizontal TerminationDefinitions Elbow Vent Length ValuesExample Formula 2 HT + VT 24.75 feetFormula 1 HT VT Formula 2 HT + VT 40 feet BGD36CFG Rear Exit / Horizontal TerminationFormula 1 HT 3.5VT Formula 2 HT + VT 24.75 feet Example Formula 2 HT + VT 40 feet Example =5 ft Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleBGD36CFG TOP or Rear Exit Vertical Termination BGD42CF Horizontal Termination BGD42CF Vertical Termination = .03 45 + 90 + 90 +90 135 = 5.4 ft= HR + HO = 5.5 + 5.4 = 10.9 ft HT + VTFormula 1 HT 3VT Formula 2 HT + VT 40 feet Example BGD36CFG PRE-INSTALLATION Preparation Installation Wall and Ceiling ProtectionVertical Installation BGD42CF only Adjustable Firestop InstallationSpace around the pipe. Nail Headers between the joist forUsing Flexible Vent Components Horizontal AIR Terminal InstallationVertical Venting Installation Using Rigid Vent ComponentsExtended Horizontal and Corner AIR Terminal Installation GAS Installation Mobile Home InstallationOptional Wall Switch Installation Excluding BGD36CFG Restricting Vertical VentsFraming Installing StandoffsCavity BGD36CFG BGD42CF 46 1/2BGD36CFG Minimum Mantel and Enclosure Clearances Finished Floor Installation Clean Face Surround Minimum Enclosure ClearancesConvex Concave Optional Clean Face Trim KIT Installation Hearth Installation37 3 BGD42CF Minimum Mantel and Enclosure Clearances LOG Placement Door Installation / RemovalGLASS/DOOR Replacement Finishing BGD36CF FinishingGrate Installation Door Trim LOG PlacementGrate BGD36CFG Finishing Optional Blower Installation BGD42CF Accessing the BlowerInstalling the Blower BGD36CFG Accessing the Blower FigureGD36 Thermostatic Sensor Control Electrical Code in the United StatesBGD36CFG Burner Switch / Wiring Diagram Gauge FeetBGD36CFG Light Switch / Wiring Diagram Receptacle Wiring Diagram Lighting Instructions Operation BGD36CF & BGD42CFTo Turn OFF GAS Maintenance For Your Safety Read Before OperatingOperation BGD36CFG Operating InstructionsAdjustments Venturi AdjustmentBGD36CFG Venturi Adjustment Pilot Burner Adjustment Excluding BGD36CFGFlame Adjustment BGD36CF Flame CharacteristicsBGD42CF Flame Characteristics BGD36CFG Flame CharacteristicsCommon Replacements BGD36CFG ReplacementsBGD42CF Replacements W415-0661 / C BGD36CFG Trouble Shooting Guide Symptom Problem Test SolutionPilot lights Wiring / Connection Right orderNot turn on Module or Valve Ing, touch black lead to ground valve bodyGas valve has An interlock deviceWhich will not allow Pilot burner to be Lit until the thermoModel BGD42CF only