BGD36CFG LIGHT SWITCH / WIRING DIAGRAM

A wall switch must be installed in a convenient location for the light operation.

The recommended maximum lead length depends on wire size:

WIRE SIZE

MAX. LENGTH

14 gauge

100 feet

16 gauge

60 feet

18 gauge

40 feet

A 20’ length of millivolt wire is connected to the gas valve for the light wall switch. However if a greater length is required route 2- strand (solid core) wire through the electrical hole located at the bottom left side of the unit.

FIGURE 126

W415-0661 / C / 02.20.08

Image 36
Contents Installation Operating Instructions Table of Contents W415-0661 / C General Instructions General InformationCare of Glass and Plated Parts For example in Massachusetts StateUnit Dimensions Installation Overview38 1/2 24 1/4Venting Venting LengthsW415-0661 / C Typical Minimum and Maximum Vent Lengths See Venting SectionSpecial Vent Installations TOP Exit Installation Rear Exit InstallationPeriscope Termination Corner TerminationVenting Application Flow Chart Fireplace Vent Exit Rear Exit TOP ExitHorizontal Termination Vertical Termination When HT VT BGD36CFG TOP Exit / Horizontal TerminationDefinitions Elbow Vent Length ValuesExample Formula 2 HT + VT 24.75 feetBGD36CFG Rear Exit / Horizontal Termination Formula 1 HT VT Formula 2 HT + VT 40 feetFormula 1 HT 3.5VT Formula 2 HT + VT 24.75 feet Example Formula 2 HT + VT 40 feet Example =5 ft Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleBGD36CFG TOP or Rear Exit Vertical Termination BGD42CF Horizontal Termination BGD42CF Vertical Termination = .03 45 + 90 + 90 +90 135 = 5.4 ft= HR + HO = 5.5 + 5.4 = 10.9 ft HT + VTFormula 1 HT 3VT Formula 2 HT + VT 40 feet Example BGD36CFG PRE-INSTALLATION Preparation Installation Wall and Ceiling ProtectionVertical Installation BGD42CF only Adjustable Firestop InstallationSpace around the pipe. Nail Headers between the joist forUsing Flexible Vent Components Horizontal AIR Terminal InstallationUsing Rigid Vent Components Vertical Venting InstallationExtended Horizontal and Corner AIR Terminal Installation GAS Installation Mobile Home InstallationOptional Wall Switch Installation Excluding BGD36CFG Restricting Vertical VentsInstalling Standoffs FramingCavity BGD36CFG BGD42CF 46 1/2BGD36CFG Minimum Mantel and Enclosure Clearances Clean Face Surround Minimum Enclosure Clearances Finished Floor InstallationConvex Concave Hearth Installation Optional Clean Face Trim KIT Installation37 3 BGD42CF Minimum Mantel and Enclosure Clearances LOG Placement Door Installation / RemovalGLASS/DOOR Replacement Finishing BGD36CF FinishingDoor Trim LOG Placement Grate InstallationGrate BGD36CFG Finishing Optional Blower Installation BGD42CF Accessing the BlowerInstalling the Blower BGD36CFG Accessing the Blower FigureGD36 Thermostatic Sensor Control Electrical Code in the United StatesBGD36CFG Burner Switch / Wiring Diagram Gauge FeetBGD36CFG Light Switch / Wiring Diagram Receptacle Wiring Diagram Operation BGD36CF & BGD42CF Lighting InstructionsTo Turn OFF GAS Maintenance For Your Safety Read Before OperatingOperation BGD36CFG Operating InstructionsAdjustments Venturi AdjustmentBGD36CFG Venturi Adjustment Pilot Burner Adjustment Excluding BGD36CFGFlame Adjustment BGD36CF Flame CharacteristicsBGD42CF Flame Characteristics BGD36CFG Flame CharacteristicsCommon Replacements BGD36CFG ReplacementsBGD42CF Replacements W415-0661 / C BGD36CFG Trouble Shooting Guide Symptom Problem Test SolutionPilot lights Wiring / Connection Right orderNot turn on Module or Valve Ing, touch black lead to ground valve bodyGas valve has An interlock deviceWhich will not allow Pilot burner to be Lit until the thermoModel BGD42CF only