Napoleon Fireplaces BGD36CFGN, BGD42CFN, BGD36CFNTR Common Replacements, BGD36CFG Replacements

Page 42

42

COMMON REPLACEMENTS

Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon® dealer or distributor.

When ordering replacement parts always give the following informa- tion:

1.MODEL & SERIAL NUMBER OF FIREPLACE

2.INSTALLATION DATE OF FIREPLACE

3.PART NUMBER

4.DESCRIPTION OF PART

5.FINISH

6.TOP OR REAR VENT

!WARNING

Failure to position the parts in accordance with these diagrams or failure to use only parts specified approved with this appliance may result in property damage or personal injury.

*IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR FURTHER INFORMATION,

CONTACT YOUR NAPOLEON® DEALER.

COMMON COMPONENTS:

#

PART NO.

DESCRIPTION

1

W357-0001

PIEZO IGNITER

2

W680-0004

THERMOPILE

3

W680-0005

THERMOCOUPLE**

4W010-0800 PROPANE GAS PILOT ASSEMBLY

4W010-0801 NATURAL GAS PILOT ASSEMBLY

5W455-0069 NATURAL GAS PILOT INJECTOR

5W455-0067 PROPANE GAS PILOT INJECTOR

6W725-0025 NATURAL GAS VALVE

6W725-0026 PROPANE GAS VALVE

7*

W385-0334

NAPOLEON® LOGO

8*

W750-0112

20FT OF WIRE

9*

W361-0016

GLOWING EMBERS

10*

W550-0001

CHARCOAL EMBERS

 

 

 

 

 

! WARNING

**This is a fast acting thermocouple. It is an integral safety

component. Replace only with a fast acting thermocouple supplied

by Wolf Steel Ltd.

COMMON ACCESSORIES:

11*

W573-0007

10.3OZ TUBE HIGH TEMP SEALANT

12*

W690-0001

MILLIVOLT THERMOSTAT

13*

W690-0010B

REMOTE CONTROL - Advantage

14*

W660-0011B

REMOTE CONTROL - ADVANTAGE PLUS

15*

GD65

FAN KIT

16

GZ550-1KT

BLOWER KIT

17*

B440-KT

BLOWER

18*

W500-0033

VARIABLE SPEED SWITCH WALL MOUNTING PLATE

19*

W690-0005

THERMOSTAT, 110 VOLT for use with ga-566

20*

W660-0026

PROGRAMMABLE TIMER

21

GA-566

HOT AIR KIT

22

GA-72

HOT AIR EXHAUST KIT

23

GA-70

EXTENSION KIT 5FT

24*

ANI-K

ANDIRONS - BLACK

25*

ANI-G

ANDIRONS - GOLD PLATED

26*

270

PAINT, BLACK - 13OZ

27*

W361-0014

VERMICULITE

28*

GD36

THERMOSTATIC SENSOR CONTROL KIT

 

 

FOR USE WITH GD65 ONLY

BGD36CF(G) REPLACEMENTS

BGD36CF(G) COMPONENTS:

29*

W225-0058

BLACK DOOR FRAME

30

W455-0048

#47 NATURAL GAS ORIFICE

30

W455-0047

#56 PROPANE GAS ORIFICE

31*

W010-0370

WALL SUPPORT ASSEMBLY

32

W010-0539

FLUE PIPE ASSEMBLY c/w GASKET

33*

W010-0538

FLUE CAP c/w GASKET

34

W010-0764

PAN BURNER

35

GL-639

LOG SET

36

W135-0183

BACK LOG (#1)

37W135-0184 LEFT MIDDLE LOG (#2)

38W135-0185 RIGHT MIDDLE LOG (#3)

39W135-0186 LEFT CROSSOVER LOG (#4)

40W135-0187 MIDDLE CROSSOVER LOG (#5)

41W135-0188 RIGHT CROSSOVER LOG (#6)

42W010-0454 GLASS c/w GASKET

43W010-0516 BLACK DOOR C/W GLASS

44W010-1774 FIRESTOP SPACER

BGD36CFG COMPONENTS:

45

W100-0102

BURNER TUBE

46*

W300-0102

CLEAR GLASS EMBERS

47*

W010-1835

GLASS EMBER TRAY

48*

W387-0004

HIGH TEMPERATURE LIGHT ASSEMBLY

49*

W387-0009

HALOGEN BULB 5W

50*

W725-0032

DEXEN VALVE EI NATURAL GAS

51*

W725-0049

DEXEN VALVE 3V PROPANE

52W455-0049 PILOT INJECTOR - LP

53W455-0071 PILOT INJECTOR - NG

54 W720-0092

PILOT TUBE

55W100-0069 PILOT ASSEMBLY - NG

56W100-0093 PILOT ASSEMBLY - LP

BGD36CF(G) FLEXIBLE VENT KITS:

 

GD220(5FT)

4" FLEXIBLE VENT PIPE - (5 FT) C/W SPACERS

57*

W010-0397

58*

W410-0017

7" FLEXIBLE VENT PIPE - (5 FT)

 

GD330 (10 FT)

 

FT)

59*

W410-0018

7" FLEXIBLE VENT PIPE - (10

60*

W010-0300

4" FLEXIBLE VENT PIPE - (10

FT) C/W SPACERS

61*

W010-0370

WALL SUPPORT ASSEMBLY

 

BGD36CF(G) TERMINAL KITS:

62

PERISCOPE

-

GD201

63

WALL TERMINAL KIT

-

GD222

BGD36CF(G) ROOF TERMINAL KITS:

64*

1/12 TO 7/12 PITCH

-

GD110

65*

8/12 TO 12/12 PITCH

-

GD111

66*

FLAT ROOF

 

-

GD112

67*

W490-0073

4/7 INNER/OUTER SLEEVE

 

68

W670-0006

4/7 TERMINAL

 

 

69

W170-0063

STORM COLLAR

 

 

70

W010-0453

ROOF SUPPORT

 

 

71W263-0054 / ROOF FLASHING

W263-0055 /

W263-0056

BGD36CF(G) ACCESSORIES:

72*

W175-0001

4" COUPLER

73*

W175-0013

7" COUPLER

74*

W615-0044

FIRESTOP SPACER - FLEXIBLE VENTING

75*

W500-0103

TERMINAL EXTENSION PLATE

76

GD-301

HEAT GUARD

77*

W010-0370

WALL SUPPORT ASSEMBLY

78*

W175-0053

DURA-VENT ZERO CLEARANCE ADAPTOR

79

VS47KT

VENT SLEEVE

80W170-0063 VENT PIPE COLLAR

81W585-0072 VENT PIPE SHIELD

82*

W175-0159

CONVERSION KIT - NG TO LP

83*

W175-0164

CONVERSION KIT - LP TO NG

84*

GD831KT

DECORATIVE BRICK PANELS - SANDSTONE

85*

CDV202-PB

DOOR TRIM KIT

86*

GD-565-1KT

SAFETY SCREEN

87*

S36WN

WAVE SURROUND - BROWN

87*

S36WP

WAVE SURROUND - PEWTER

87*

S36CCN

CONCAVE SURROUND - BROWN

87*

S36CCP

CONCAVE SURROUND - PEWTER

87*

S36CVN

CONVEX SURROUND - BROWN

87*

S36CVP

CONVEX SURROUND - PEWTER

88*

CFT36W

UPPER TRIM FOR WAVE SURROUND

88*

CFT36CC

UPPER TRIM FOR CONCAVE SURROUND

88*

CFT36CV

UPPER TRIM FOR CONVEX SURROUND

W415-0661 / C / 02.20.08

Image 42
Contents Installation Operating Instructions Table of Contents W415-0661 / C Care of Glass and Plated Parts General InstructionsGeneral Information For example in Massachusetts State38 1/2 Unit DimensionsInstallation Overview 24 1/4Venting Venting LengthsW415-0661 / C Typical Minimum and Maximum Vent Lengths See Venting SectionPeriscope Termination Special Vent InstallationsTOP Exit Installation Rear Exit Installation Corner TerminationVenting Application Flow Chart Fireplace Vent Exit Rear Exit TOP ExitHorizontal Termination Vertical Termination Definitions When HT VTBGD36CFG TOP Exit / Horizontal Termination Elbow Vent Length ValuesExample Formula 2 HT + VT 24.75 feetBGD36CFG Rear Exit / Horizontal Termination Formula 1 HT VT Formula 2 HT + VT 40 feetFormula 1 HT 3.5VT Formula 2 HT + VT 24.75 feet Example Formula 2 HT + VT 40 feet Example =5 ft Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleBGD36CFG TOP or Rear Exit Vertical Termination BGD42CF Horizontal Termination = HR + HO = 5.5 + 5.4 = 10.9 ft BGD42CF Vertical Termination= .03 45 + 90 + 90 +90 135 = 5.4 ft HT + VTFormula 1 HT 3VT Formula 2 HT + VT 40 feet Example BGD36CFG PRE-INSTALLATION Preparation Installation Wall and Ceiling ProtectionSpace around the pipe. Nail Vertical InstallationBGD42CF only Adjustable Firestop Installation Headers between the joist forUsing Flexible Vent Components Horizontal AIR Terminal InstallationUsing Rigid Vent Components Vertical Venting InstallationExtended Horizontal and Corner AIR Terminal Installation Optional Wall Switch Installation Excluding BGD36CFG GAS InstallationMobile Home Installation Restricting Vertical VentsInstalling Standoffs FramingCavity BGD36CFG BGD42CF 46 1/2BGD36CFG Minimum Mantel and Enclosure Clearances Clean Face Surround Minimum Enclosure Clearances Finished Floor InstallationConvex Concave Hearth Installation Optional Clean Face Trim KIT Installation37 3 BGD42CF Minimum Mantel and Enclosure Clearances GLASS/DOOR Replacement LOG PlacementDoor Installation / Removal Finishing BGD36CF FinishingDoor Trim LOG Placement Grate InstallationGrate BGD36CFG Finishing Installing the Blower Optional Blower InstallationBGD42CF Accessing the Blower BGD36CFG Accessing the Blower FigureGD36 Thermostatic Sensor Control Electrical Code in the United StatesBGD36CFG Burner Switch / Wiring Diagram Gauge FeetBGD36CFG Light Switch / Wiring Diagram Receptacle Wiring Diagram Operation BGD36CF & BGD42CF Lighting InstructionsTo Turn OFF GAS Operation BGD36CFG MaintenanceFor Your Safety Read Before Operating Operating InstructionsBGD36CFG Venturi Adjustment AdjustmentsVenturi Adjustment Pilot Burner Adjustment Excluding BGD36CFGBGD42CF Flame Characteristics Flame AdjustmentBGD36CF Flame Characteristics BGD36CFG Flame CharacteristicsCommon Replacements BGD36CFG ReplacementsBGD42CF Replacements W415-0661 / C BGD36CFG Trouble Shooting Guide Symptom Problem Test SolutionNot turn on Module or Valve Pilot lights Wiring / ConnectionRight order Ing, touch black lead to ground valve bodyWhich will not allow Pilot burner to be Gas valve hasAn interlock device Lit until the thermoModel BGD42CF only