Napoleon Fireplaces BGD36CFGN manual Operation BGD36CFG, Operating Instructions, To Turn OFF GAS

Page 39

39

OPERATION BGD36CFG

FOR YOUR SAFETY READ BEFORE OPERATING

! WARNING

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING

PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

 

A. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE

REPLACE ANY PART OF THE CONTROL SYSTEM AND

 

 

WHICH AUTOMATICALLY LIGHTS THE PILOT. DO NOT TRY

ANY GAS CONTROL WHICH HAS BEEN UNDER

 

 

TO LIGHT BY HAND.

 

WATER.

 

 

 

 

 

B. BEFORE OPERATING SMELL ALL AROUND THE FIREPLACE

WHAT TO DO IF YOU SMELL GAS:

 

 

AREA FOR GAS AND NEXT TO THE FLOOR BECAUSE SOME

• TURN OFF ALL GAS TO THE FIREPLACE.

 

 

GAS IS HEAVIER THAN AIR AND WILL SETTLE ON THE

• OPEN WINDOWS.

 

 

FLOOR.

 

• DO NOT TRY TO LIGHT ANY APPLIANCE.

 

C. USE ONLY YOUR HAND TO TURN THE GAS CONTROL

 

• DO NOT TOUCH ANY ELECTRIC SWITCH; DO NOT

 

 

KNOB. NEVER USE TOOLS. IF THE KNOB WILL NOT TURN

USE ANY PHONE IN YOUR BUILDING.

 

 

BY HAND, DO NOT TRY TO REPAIR IT. CALL A QUALIFIED

• IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A

 

 

SERVICE TECHNICIAN. FORCE OR ATTEMPTED REPAIR

NEIGHBOUR'S PHONE FOLLOW THE (GAS

 

 

MAY RESULT IN A FIRE OR EXPLOSION.

 

SUPPLIER'S) INSTRUCTIONS.

 

D. DO NOT USE THIS FIREPLACE IF ANY PART HAS BEEN

• IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL

 

 

UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE

THE FIRE DEPARTMENT.

 

 

TECHNICIAN TO INSPECT THE FIREPLACE AND

 

 

 

 

 

 

 

 

 

 

 

OPERATING INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

STOP! READ THE ABOVE SAFETY INFORMATION ON

NEXT STEP.

 

 

 

 

 

 

THIS LABEL.

 

8. CLOSE THE GLASS DOOR.

 

2.

TURN REMOTE WALL SWITCH TO OFF POSITION.

 

9. TURN MANUAL SHUTOFF VALVE COUNTER-

 

3.

TURN OFF ALL ELECTRIC POWER TO THE FIREPLACE

CLOCKWISE

TO ON.

 

 

AND REMOVE BATTERIES.

 

10. TURN ON ALL ELECTRIC POWER TO THE FIREPLACE

 

4.

THIS FIREPLACE IS EQUIPPED WITH AN IGNITION

 

AND RE-INSTALL BATTERIES.

 

 

DEVICE WHICH AUTOMATICALLY LIGHTS THE PILOT. DO

11. TURN ON REMOTE WALL SWITCH TO ON POSITION.

 

 

NOT TRY TO LIGHT THE PILOT BY HAND.

 

12. IF FIREPLACE WILL NOT OPERATE, FOLLOW

 

5.

TURN MANUAL SHUTOFF VALVE CLOCKWISE

TO

INSTRUCTIONS "TO TURN OFF GAS" AND CALL YOUR

 

 

OFF.

 

SERVICE TECHNICIAN OR GAS SUPPLIER.

 

6.

OPEN THE GLASS DOOR.

 

 

 

 

 

Manual Shut-off Valve

 

7.

WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS. IF

 

 

 

 

 

 

Shown in “OFF”

 

 

YOU SMELL GAS INCLUDING NEAR THE FLOOR, STOP!

 

 

 

 

 

position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOLLOW "B" IN THE ABOVE SAFETY INFORMATION ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THIS LABEL. IF YOU DON'T SMELL GAS GO TO THE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO TURN OFF GAS

1.TURN OFF REMOTE WALL SWITCH TO THE FIREPLACE.

2.TURN OFF ALL ELECTRICAL POWER TO THE FIREPLACE IF SERVICE IS TO BE PERFORMED.

3.TURN MANUAL SHUTOFF VALVE CLOCKWISE TO OFF. DO NOT FORCE.

MAINTENANCE

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. This fi replace and its venting system should be inspected before use and at least annually by a qualifi ed service person. The fi replace area must be kept clear and free of combustible materials, gasoline or other fl ammable vapours and liquids. The fl ow of combustion and ventilation air must not be obstructed.

1.In order to properly clean the burner and pilot assembly, remove the logs to expose both assemblies.

2.Keep the control compartment, logs, burner, air shutter

opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year.

3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly.

4.Check to see that the pilot fl ame is large enough to engulf the thermocouple and thermopile and reaches toward the burner with the third jet.

5.Replace the cleaned logs.

6.Check to see that the main burner ignites completely on all open- ings when the gas knob for the burner is turned on. A 5 to 10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon® dealer / distributor.

7.Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if necessary.

W415-0661 / C / 02.20.08

Image 39
Contents Installation Operating Instructions Table of Contents W415-0661 / C For example in Massachusetts State General InstructionsGeneral Information Care of Glass and Plated Parts24 1/4 Unit DimensionsInstallation Overview 38 1/2Venting Lengths VentingW415-0661 / C See Venting Section Typical Minimum and Maximum Vent LengthsCorner Termination Special Vent InstallationsTOP Exit Installation Rear Exit Installation Periscope TerminationVenting Application Flow Chart Fireplace Vent Exit Rear Exit TOP ExitHorizontal Termination Vertical Termination Elbow Vent Length Values When HT VTBGD36CFG TOP Exit / Horizontal Termination DefinitionsFormula 2 HT + VT 24.75 feet ExampleBGD36CFG Rear Exit / Horizontal Termination Formula 1 HT VT Formula 2 HT + VT 40 feetFormula 1 HT 3.5VT Formula 2 HT + VT 24.75 feet Example Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Formula 2 HT + VT 40 feet Example =5 ftBGD36CFG TOP or Rear Exit Vertical Termination BGD42CF Horizontal Termination HT + VT BGD42CF Vertical Termination= .03 45 + 90 + 90 +90 135 = 5.4 ft = HR + HO = 5.5 + 5.4 = 10.9 ftFormula 1 HT 3VT Formula 2 HT + VT 40 feet Example Installation Wall and Ceiling Protection BGD36CFG PRE-INSTALLATION PreparationHeaders between the joist for Vertical InstallationBGD42CF only Adjustable Firestop Installation Space around the pipe. NailHorizontal AIR Terminal Installation Using Flexible Vent ComponentsUsing Rigid Vent Components Vertical Venting InstallationExtended Horizontal and Corner AIR Terminal Installation Restricting Vertical Vents GAS InstallationMobile Home Installation Optional Wall Switch Installation Excluding BGD36CFGInstalling Standoffs FramingCavity 46 1/2 BGD36CFG BGD42CFBGD36CFG Minimum Mantel and Enclosure Clearances Clean Face Surround Minimum Enclosure Clearances Finished Floor InstallationConvex Concave Hearth Installation Optional Clean Face Trim KIT Installation37 3 BGD42CF Minimum Mantel and Enclosure Clearances Finishing BGD36CF Finishing LOG PlacementDoor Installation / Removal GLASS/DOOR ReplacementDoor Trim LOG Placement Grate InstallationGrate BGD36CFG Finishing BGD36CFG Accessing the Blower Figure Optional Blower InstallationBGD42CF Accessing the Blower Installing the BlowerElectrical Code in the United States GD36 Thermostatic Sensor ControlGauge Feet BGD36CFG Burner Switch / Wiring DiagramBGD36CFG Light Switch / Wiring Diagram Receptacle Wiring Diagram Operation BGD36CF & BGD42CF Lighting InstructionsTo Turn OFF GAS Operating Instructions MaintenanceFor Your Safety Read Before Operating Operation BGD36CFGPilot Burner Adjustment Excluding BGD36CFG AdjustmentsVenturi Adjustment BGD36CFG Venturi AdjustmentBGD36CFG Flame Characteristics Flame AdjustmentBGD36CF Flame Characteristics BGD42CF Flame CharacteristicsBGD36CFG Replacements Common ReplacementsBGD42CF Replacements W415-0661 / C Symptom Problem Test Solution BGD36CFG Trouble Shooting GuideIng, touch black lead to ground valve body Pilot lights Wiring / ConnectionRight order Not turn on Module or ValveLit until the thermo Gas valve hasAn interlock device Which will not allow Pilot burner to beModel BGD42CF only