BGD36CF / BGD42CF TROUBLE SHOOTING GUIDE

BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR OPEN.

 

SYMPTOM

 

PROBLEM

 

TEST SOLUTION

 

 

 

 

 

 

Main burner goes out;

Pilot fl ame is not large enough or

-

turn up pilot fl ame.

pilot stays on.

not engulfi ng the thermopile

- replace pilot assembly.

 

 

Thermopile shorting

- clean thermopile connection to the valve. Reconnect.

 

 

 

 

- replace thermopile / valve.

 

 

Remote wall switch wire is too

-

shorten wire to correct length or wire gauge.

 

 

long; too much resistance in the

 

 

 

 

 

 

 

 

 

system.

 

 

 

 

 

 

 

 

 

Faulty thermostat or switch.

-

replace.

 

 

 

 

 

 

 

 

 

Main burner goes out;

Refer to "MAIN BURNER GOES OUT; PILOT STAYS ON"

 

pilot goes out.

 

 

 

 

 

 

 

 

 

Vent is blocked

-

check for vent blockage.

 

 

 

 

Vent is re-circulating

-

check joint seals and installation.

 

 

 

 

 

 

 

 

 

 

 

 

 

4" fl exible vent has become dis-

-

re-attach to fi replace.

 

 

connected from fi replace.

-

7"ø cap was not replaced

 

 

Pilot goes out when the

 

System is not correctly purged.

-

purge the gas line.

 

gas knob is released.

 

 

 

 

 

 

 

 

 

 

 

Out of propane gas.

-

fi ll the tank.

 

The gas valve has

 

 

 

Pilot fl ame is not large enough

-

turn up the pilot fl ame.

 

 

an interlock device

 

 

 

 

 

 

 

 

 

 

 

Pilot fl ame is not engulfi ng the

- gently twist the pilot head to improve the fl ame pattern around the thermo-

 

which will not allow

 

 

the pilot burner to be

 

thermocouple.

couple.

 

lit until the thermo-

Thermocouple shorting / faulty.

-

loosen and tighten thermocouple.

 

couple has cooled.

 

 

-

clean thermocouple and valve connection.

 

Allow approximately

 

 

-

replace thermocouple.

 

60 seconds for the

 

 

-

replace valve.

 

thermocouple to

Faulty valve.

-

replace.

 

cool.

 

 

 

 

 

 

 

 

 

Pilot burning; no gas to

Themostat or switch is defec-

-

connect a jumper wire across the wall switch terminals; if main burner lights,

 

 

main burner; gas knob

tive.

replace switch / thermostat.

is on 'HI'; wall switch /

Wall switch wiring is defective.

- disconnect the switch wires & connect a jumper wire across terminals 1 & 3; if

thermostat is on.

 

 

the main burner lights, check the wires for defects and / or replace wires.

 

 

Main burner orifi ce is plugged.

-

remove stoppage in orifi ce.

 

 

Faulty valve.

-

replace.

 

 

 

 

 

 

 

Pilot will not light.

 

No spark at pilot burner

-

check if pilot can be lit by a match

 

 

 

 

 

 

 

-

check that the wire is connected to the push button igniter.

 

 

 

 

-

check if the push button igniter needs tightening.

 

 

 

 

-

replace the wire if the wire insulation is broken or frayed.

 

 

 

 

-

replace the electrode if the ceramic insulator is cracked or broken.

 

 

 

 

-

replace the push button igniter.

 

 

Out of propane gas

-

fi ll the tank.

 

 

Spark gap is incorrect

- spark gap should be 0.150" to 0.175" (5/32" to 11/64" approx.) from the electrode

 

 

 

 

tip and the pilot burner. To ensure proper electrode location, tighten securing nut

 

 

 

 

(fi nger tight plus 1/4 turn).

 

 

No gas at the pilot burner

-

check that the manual valve is turned on.

 

 

 

 

 

 

 

 

-

check the pilot orifi ce for blockage.

 

 

 

 

-

replace the valve.

 

 

 

 

-

call the gas distributor.

 

Pilot goes out while

Gas piping is undersized.

- turn on all gas appliances and see if pilot fl ame fl utters, diminishes or

standing; Main

 

 

extinguishes, especially when main burner ignites. Monitor appliance

burner is in 'OFF'

 

 

supply working pressure.

position.

 

 

-

check if supply piping size is to code. Correct all undersized piping.

W415-0661 / C / 02.20.08

Image 47
Contents Installation Operating Instructions Table of Contents W415-0661 / C For example in Massachusetts State General InstructionsGeneral Information Care of Glass and Plated Parts24 1/4 Unit DimensionsInstallation Overview 38 1/2Venting Lengths VentingW415-0661 / C See Venting Section Typical Minimum and Maximum Vent LengthsCorner Termination Special Vent InstallationsTOP Exit Installation Rear Exit Installation Periscope TerminationHorizontal Termination Vertical Termination Venting Application Flow ChartFireplace Vent Exit Rear Exit TOP Exit Elbow Vent Length Values When HT VTBGD36CFG TOP Exit / Horizontal Termination DefinitionsFormula 2 HT + VT 24.75 feet ExampleFormula 1 HT 3.5VT Formula 2 HT + VT 24.75 feet Example BGD36CFG Rear Exit / Horizontal TerminationFormula 1 HT VT Formula 2 HT + VT 40 feet Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Formula 2 HT + VT 40 feet Example =5 ftBGD36CFG TOP or Rear Exit Vertical Termination BGD42CF Horizontal Termination HT + VT BGD42CF Vertical Termination= .03 45 + 90 + 90 +90 135 = 5.4 ft = HR + HO = 5.5 + 5.4 = 10.9 ftFormula 1 HT 3VT Formula 2 HT + VT 40 feet Example Installation Wall and Ceiling Protection BGD36CFG PRE-INSTALLATION PreparationHeaders between the joist for Vertical InstallationBGD42CF only Adjustable Firestop Installation Space around the pipe. NailHorizontal AIR Terminal Installation Using Flexible Vent ComponentsExtended Horizontal and Corner AIR Terminal Installation Using Rigid Vent ComponentsVertical Venting Installation Restricting Vertical Vents GAS InstallationMobile Home Installation Optional Wall Switch Installation Excluding BGD36CFGCavity Installing StandoffsFraming 46 1/2 BGD36CFG BGD42CFBGD36CFG Minimum Mantel and Enclosure Clearances Convex Concave Clean Face Surround Minimum Enclosure ClearancesFinished Floor Installation 37 3 Hearth InstallationOptional Clean Face Trim KIT Installation BGD42CF Minimum Mantel and Enclosure Clearances Finishing BGD36CF Finishing LOG PlacementDoor Installation / Removal GLASS/DOOR ReplacementGrate Door Trim LOG PlacementGrate Installation BGD36CFG Finishing BGD36CFG Accessing the Blower Figure Optional Blower InstallationBGD42CF Accessing the Blower Installing the BlowerElectrical Code in the United States GD36 Thermostatic Sensor ControlGauge Feet BGD36CFG Burner Switch / Wiring DiagramBGD36CFG Light Switch / Wiring Diagram Receptacle Wiring Diagram To Turn OFF GAS Operation BGD36CF & BGD42CFLighting Instructions Operating Instructions MaintenanceFor Your Safety Read Before Operating Operation BGD36CFGPilot Burner Adjustment Excluding BGD36CFG AdjustmentsVenturi Adjustment BGD36CFG Venturi AdjustmentBGD36CFG Flame Characteristics Flame AdjustmentBGD36CF Flame Characteristics BGD42CF Flame CharacteristicsBGD36CFG Replacements Common ReplacementsBGD42CF Replacements W415-0661 / C Symptom Problem Test Solution BGD36CFG Trouble Shooting GuideIng, touch black lead to ground valve body Pilot lights Wiring / ConnectionRight order Not turn on Module or ValveLit until the thermo Gas valve hasAn interlock device Which will not allow Pilot burner to beModel BGD42CF only