Napoleon Fireplaces BGD42CFN, BGD36CFGN, BGD36CFNTR Door Trim LOG Placement, Grate Installation

Page 31

31

DOOR TRIM

LOG PLACEMENT

The BGD42CF comes complete with top door trim

(W715-0729).

1.Guide the arms of the trim into the slots that are slightly hidden under the facing through the open- ing between the top of the door and the bottom edge of the facing as illustrated in the front view.

2.Slide the arm into the slot far enough to allow the front edge of the trim to go in behind the facing.

3.Let the bracket come forward towards the back of the facing and allow the trim to rest on the inside lip, this position will allow the notch on the arm of the trim to fall into place on the edge of the slot.

 

SLOT

FACING

FIGURE 102a

 

TRIM

DOOR

 

BGD42CF FRONT VIEW

NOTCH

FIGURE 102b

INSIDE LIP

S

 

 

 

 

E

 

 

 

 

E

 

 

 

 

-

 

 

 

 

T

 

 

 

 

H

 

 

 

 

 

R

 

 

 

 

 

U

 

 

 

 

 

W

 

 

 

 

I

 

 

O

D

N

 

 

W

 

 

 

 

 

 

 

 

 

 

 

BGD42CF SIDE VIEW

PHAZERTM logs and glowing embers, exclusive to Napoleon® Fireplaces, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect. Log colours may vary. During the initial use of the fi replace, the colours will become more uniform as colour pigments burn in during the heat activated curing process.

FIGURE 104

1.Place the cutout in the bottom of log #1 behind the pilot assembly. Rest the log against the back wall of the fi rebox.

FIGURE 105

FIGURE 102c

BGD42CF WITH TOP DOOR TRIM INSTALLED

GRATE INSTALLATION

The grate for this

 

fi replace has been

GRATE

removed for shipping

purposes.

 

The grate must be in-

 

stalled before the logs

PINS

are installed.

 

Remove the packag-

 

ing from the grate and

 

install onto the two pins

 

as illustrated.

 

FIGURE 103

2.Move the two small logs (#2 & #3) into position, lining up the studs located on the burner with the holes on the bottom of the logs.

3.Tear the glowing embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs (#2 & #3). Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fi bre hairs will glow. The ember material will only glow when exposed to direct fl ame; however, care should be taken to not block the burner ports. Blocked burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. PHAZERtm logs glow when exposed to direct fl ame.

FIGURE 106

4.Place the bottom of the left crossover log (#4) onto the stud on the left side of the log support. The top of the log should rest in the pocket on the back log.

FIGURE 107

5.Place the bottom of the right crossover log (#5) onto the stud on the right side of the log support. The top of the log should rest in the pocket on the left crossover log (#4).

W415-0661 / C / 02.20.08

Image 31
Contents Installation Operating Instructions Table of Contents W415-0661 / C For example in Massachusetts State General InstructionsGeneral Information Care of Glass and Plated Parts24 1/4 Unit DimensionsInstallation Overview 38 1/2Venting Lengths VentingW415-0661 / C See Venting Section Typical Minimum and Maximum Vent LengthsCorner Termination Special Vent InstallationsTOP Exit Installation Rear Exit Installation Periscope TerminationFireplace Vent Exit Rear Exit TOP Exit Venting Application Flow ChartHorizontal Termination Vertical Termination Elbow Vent Length Values When HT VTBGD36CFG TOP Exit / Horizontal Termination DefinitionsFormula 2 HT + VT 24.75 feet ExampleFormula 1 HT VT Formula 2 HT + VT 40 feet BGD36CFG Rear Exit / Horizontal TerminationFormula 1 HT 3.5VT Formula 2 HT + VT 24.75 feet Example Formula 1 HT 3VT Formula 2 HT + VT 40 feet Example Formula 2 HT + VT 40 feet Example =5 ftBGD36CFG TOP or Rear Exit Vertical Termination BGD42CF Horizontal Termination HT + VT BGD42CF Vertical Termination= .03 45 + 90 + 90 +90 135 = 5.4 ft = HR + HO = 5.5 + 5.4 = 10.9 ftFormula 1 HT 3VT Formula 2 HT + VT 40 feet Example Installation Wall and Ceiling Protection BGD36CFG PRE-INSTALLATION PreparationHeaders between the joist for Vertical InstallationBGD42CF only Adjustable Firestop Installation Space around the pipe. NailHorizontal AIR Terminal Installation Using Flexible Vent ComponentsVertical Venting Installation Using Rigid Vent ComponentsExtended Horizontal and Corner AIR Terminal Installation Restricting Vertical Vents GAS InstallationMobile Home Installation Optional Wall Switch Installation Excluding BGD36CFGFraming Installing StandoffsCavity 46 1/2 BGD36CFG BGD42CFBGD36CFG Minimum Mantel and Enclosure Clearances Finished Floor Installation Clean Face Surround Minimum Enclosure ClearancesConvex Concave Optional Clean Face Trim KIT Installation Hearth Installation37 3 BGD42CF Minimum Mantel and Enclosure Clearances Finishing BGD36CF Finishing LOG PlacementDoor Installation / Removal GLASS/DOOR ReplacementGrate Installation Door Trim LOG PlacementGrate BGD36CFG Finishing BGD36CFG Accessing the Blower Figure Optional Blower InstallationBGD42CF Accessing the Blower Installing the BlowerElectrical Code in the United States GD36 Thermostatic Sensor ControlGauge Feet BGD36CFG Burner Switch / Wiring DiagramBGD36CFG Light Switch / Wiring Diagram Receptacle Wiring Diagram Lighting Instructions Operation BGD36CF & BGD42CFTo Turn OFF GAS Operating Instructions MaintenanceFor Your Safety Read Before Operating Operation BGD36CFGPilot Burner Adjustment Excluding BGD36CFG AdjustmentsVenturi Adjustment BGD36CFG Venturi AdjustmentBGD36CFG Flame Characteristics Flame AdjustmentBGD36CF Flame Characteristics BGD42CF Flame CharacteristicsBGD36CFG Replacements Common ReplacementsBGD42CF Replacements W415-0661 / C Symptom Problem Test Solution BGD36CFG Trouble Shooting GuideIng, touch black lead to ground valve body Pilot lights Wiring / ConnectionRight order Not turn on Module or ValveLit until the thermo Gas valve hasAn interlock device Which will not allow Pilot burner to beModel BGD42CF only