Napoleon Fireplaces BGD36CFGN, BGD42CFN, BGD36CFNTR manual Venting Lengths

Page 6

6

VENTING

THE BGD36CF(G) USES: 4" EXHAUST / 7" AIR INTAKE VENT PIPE

THE BGD42CF USES: 5" EXHAUST / 8" AIR INTAKE VENT PIPE

MODEL BGD36CF MAY BE VENTED EITHER AS A TOP VENT OR A REAR VENT.

REFER TO THE SECTION APPLICABLE TO YOUR INSTALLATION.

For safe and proper operation of the fireplace follow the venting instruction exactly. Deviation from the minimum vertical vent length can create difficulty in burner start-up and/or carboning. Provide a means for visually checking the vent connection to the fireplace after the fireplace is installed. Vent lengths that pass through unheated spaces (attics, garages, crawl spaces) should be insulated with the insulation wrapped in a protective sleeve to minimize condensation.

VENTING LENGTHS

Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp or American Metal Amerivent venting components. Minimum and maxi- mum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-Vent, Selkirk Direct Temp and American Metal Amerivent, follow the installation procedure provided with the venting components.

A starter adaptor must be used with the following vent systems and may be purchased from the corresponding supplier:

PART

4"/7"

5"/8"

SUPPLIER

Duravent

W175-0053

W175-0170

Wolf Steel

Amerivent

4DSC-N2

5DSC-N

American Metal

Direct Temp

4DT-AAN

5DT-AA

Selkirk

For Simpson Dura-Vent, Selkirk Direct Temp and American Metal Amerivent, follow the installation procedure found on the website for your venting supplier.

VENTING SUPPLIER

WEBSITE

Simpson Dura-Vent

www.duravent.com

Selkirk Direct Temp

www.selkirkcorp.com

American Metal Amerivent

www.americanmetalproducts.com

For vent systems that provide seals on the inner exhaust flue, only the outer air intake joints must be sealed using a red high temperature silicone (RTV). This same sealant may be used on both the inner exhaust and outer intake vent pipe joints of all other approved vent systems except for the exhaust vent pipe connection to the fi replace

ue collar which must be sealed using the black high temperature sealant Mill Pac.

BGD36CF(G)

When using Wolf Steel venting components, use only approved Wolf Steel rigid / fl exible components with the following termination kits: WALL TERMINAL KIT GD222, or 1/12 to 7/12 PITCH ROOF TERMI- NAL KIT GD110, 8/12 to 12/12 ROOF TERMINAL KIT GD111, FLAT ROOF TERMINAL KIT GD112 or PERISCOPE KIT GD201 (for wall penetration below grade). With fl exible venting, in conjunction with the various terminations, use either the 5 FOOT VENT KIT GD220 or the 10 FOOT VENT KIT GD330.

BGD42CF

When using Wolf Steel venting components, use only approved Wolf Steel fl exible components with the following termination kits: WALL TERMINAL KIT GD422, or 1/12 to 7/12 PITCH ROOF TERMINAL KIT GD410, 8/12 to 12/12 ROOF TERMINAL KIT GD411, FLAT ROOF TERMINAL KIT GD412 or PERISCOPE KIT GD401 (for wall penetration below grade). With fl exible venting, in conjunction with the various terminations, use either the 5 FOOT VENT KIT GD420 or the 10 FOOT VENT KIT GD430.

Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp or Ameri- can Metal Amerivent venting systems must not be combined. Wolf Steel rigid and flexible venting systems must not be combined.

These vent kits allow for either horizontal or vertical venting of the

replace. The maximum allowable horizontal run is 20 feet. The maximum allowable vertical vent length is 40 feet. The maximum number of vent connections is two horizontally or three vertically (excluding the fi replace and the air terminal connections) when us- ing fl exible venting.

For optimum flame appearance and fireplace performance, keep the vent length and number of elbows to a minimum.

REQUIRED RISE ON HORIZONTAL VENTING

 

 

 

 

BGD36CF(G)

BGD42CF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REAR VENT

RIGID VENTING

 

0" / FT

0" / FT

 

 

 

 

 

 

 

 

FLEXIBLE

 

0" / FT

0" / FT

 

 

 

 

 

 

 

VENTING

 

 

 

 

 

 

 

 

 

TOP VENT

RIGID VENTING

 

0" / FT

0" / FT

 

 

FLEXIBLE

 

0" / FT

0" / FT

 

 

 

VENTING

 

 

 

 

 

 

 

 

 

 

RIGID VENTING

0"

0"

 

 

CORNER

FLEXIBLE

6"

0"

 

 

 

VENTING

 

 

 

 

 

 

 

For optimum performance, it is recommended that all horizontal runs have a 1" rise per foot.

BGD36CF(G)

HORIZONTAL VENT SECTIONS: - A minimum clearance of 1" at the bottom and sides of the vent and 2" at the top on all horizontal runs to combustibles is required. The fi restop spacer (W010-1774) supplied with the unit must be used to maintain this clearance.

VERTICAL VENT SECTIONS: - A minimum of 1" all around the vent pipe on all vertical runs to combustibles is required except for clearances in fi replace enclosures. See "MINIMUM ENCLOSURE CLEARANCES" section. Use fi restop spacer W500-0096 (not supplied).

BGD42CF

HORIZONTAL VENT SECTIONS: A minimum clearance of 2" all around the vent pipe on all horizontal runs to combustibles is required. Use fi restop spacer W010-1778 (supplied).

VERTICAL VENT SECTIONS: A minimum of 1" all around the vent pipe on all vertical runs to combustibles is required. Use fi restop spacer W500-0028 (not supplied).

W415-0661 / C / 02.20.08

Image 6
Contents Installation Operating Instructions Table of Contents W415-0661 / C Care of Glass and Plated Parts General InstructionsGeneral Information For example in Massachusetts State38 1/2 Unit DimensionsInstallation Overview 24 1/4Venting Venting LengthsW415-0661 / C Typical Minimum and Maximum Vent Lengths See Venting SectionPeriscope Termination Special Vent InstallationsTOP Exit Installation Rear Exit Installation Corner TerminationVenting Application Flow Chart Fireplace Vent Exit Rear Exit TOP ExitHorizontal Termination Vertical Termination Definitions When HT VTBGD36CFG TOP Exit / Horizontal Termination Elbow Vent Length ValuesExample Formula 2 HT + VT 24.75 feetBGD36CFG Rear Exit / Horizontal Termination Formula 1 HT VT Formula 2 HT + VT 40 feetFormula 1 HT 3.5VT Formula 2 HT + VT 24.75 feet Example Formula 2 HT + VT 40 feet Example =5 ft Formula 1 HT 3VT Formula 2 HT + VT 40 feet ExampleBGD36CFG TOP or Rear Exit Vertical Termination BGD42CF Horizontal Termination = HR + HO = 5.5 + 5.4 = 10.9 ft BGD42CF Vertical Termination= .03 45 + 90 + 90 +90 135 = 5.4 ft HT + VTFormula 1 HT 3VT Formula 2 HT + VT 40 feet Example BGD36CFG PRE-INSTALLATION Preparation Installation Wall and Ceiling ProtectionSpace around the pipe. Nail Vertical InstallationBGD42CF only Adjustable Firestop Installation Headers between the joist forUsing Flexible Vent Components Horizontal AIR Terminal InstallationUsing Rigid Vent Components Vertical Venting InstallationExtended Horizontal and Corner AIR Terminal Installation Optional Wall Switch Installation Excluding BGD36CFG GAS InstallationMobile Home Installation Restricting Vertical VentsInstalling Standoffs FramingCavity BGD36CFG BGD42CF 46 1/2BGD36CFG Minimum Mantel and Enclosure Clearances Clean Face Surround Minimum Enclosure Clearances Finished Floor InstallationConvex Concave Hearth Installation Optional Clean Face Trim KIT Installation37 3 BGD42CF Minimum Mantel and Enclosure Clearances GLASS/DOOR Replacement LOG PlacementDoor Installation / Removal Finishing BGD36CF FinishingDoor Trim LOG Placement Grate InstallationGrate BGD36CFG Finishing Installing the Blower Optional Blower InstallationBGD42CF Accessing the Blower BGD36CFG Accessing the Blower FigureGD36 Thermostatic Sensor Control Electrical Code in the United StatesBGD36CFG Burner Switch / Wiring Diagram Gauge FeetBGD36CFG Light Switch / Wiring Diagram Receptacle Wiring Diagram Operation BGD36CF & BGD42CF Lighting InstructionsTo Turn OFF GAS Operation BGD36CFG MaintenanceFor Your Safety Read Before Operating Operating InstructionsBGD36CFG Venturi Adjustment AdjustmentsVenturi Adjustment Pilot Burner Adjustment Excluding BGD36CFGBGD42CF Flame Characteristics Flame AdjustmentBGD36CF Flame Characteristics BGD36CFG Flame CharacteristicsCommon Replacements BGD36CFG ReplacementsBGD42CF Replacements W415-0661 / C BGD36CFG Trouble Shooting Guide Symptom Problem Test SolutionNot turn on Module or Valve Pilot lights Wiring / ConnectionRight order Ing, touch black lead to ground valve bodyWhich will not allow Pilot burner to be Gas valve hasAn interlock device Lit until the thermoModel BGD42CF only