Heat & Glo LifeStyle owner manual SL-750TRS-IPI-D SL-550TRS-IPI-D SL-350TRS-C

Page 1

Owner’s Manual

Installation and Operation

Models:

SL-750TRS-IPI-D

SL-550TRS-IPI-D

SL-350TRS-C

CAUTION

DO NOT DISCARD THIS MANUAL

Important operating and maintenance instruc- tions included.

Read, understand and follow these instructions for safe installation and operation.

Leave this manual with party responsible for use and operation.

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing proper- ty damage, personal injury, or death.

Do not store or use gasoline or other flamma- ble vapors and liquids in the vicinity of this or any other appliance.

What to do if you smell gas

-Do not try to light any appliance

-Do not touch any electrical switch. Do not use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instruc- tions and the manufactured home construction and safety standard, Title 24 CFR, Part 3280 or Standard for Installa- tion in Mobile Homes, CAN/CSA Z240MH.

This appliance is only for use with the type(s) of gas indi- cated on the rating plate.

WARNING

HOT! DO NOT TOUCH.

SEVERE BURNS MAY RESULT.

CLOTHING IGNITION MAY RESULT.

Glass and other surfaces are hot during operation and cool down.

Keep children away.

CAREFULLY SUPERVISE children in same room as appliance.

Alert children and adults to hazards of high temperatures.

Do NOT operate with protective barriers open or removed.

Keep clothing, furniture, draperies and other combustibles away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. Do NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

In the Commonwealth of Massachusetts:

installation must be performed by a licensed plumber or gas fitter;

See Table of Contents for location of additional Commonwealth of Massachusetts requirements.

Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies suggests NFI certified or factory-trained professionals, or technicians supervised

by an NFI certified professional.

Í

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06

1

Image 1
Contents SL-750TRS-IPI-D SL-550TRS-IPI-D SL-350TRS-C Installation and OperationSafety and Warning Information Table of Contents SL-350TRS-C Log Set AssemblySL-350TRS-C NG, LP Service Parts ListStanding Pilot Ignition Valve AssemblySL-550TRS-IPI-D SL-550TRS-IPI-D Part number list on following Log Set AssemblySL-750TRS-IPI-D Intermittent Pilot Ignition Valve Assembly Service Parts SL-750TRS-IPI-D, SL-550TRS-IPI-DInstallation Codes High Altitude InstallationsAppliance Certification CertificationVent Directly BELOW. Keep Clear of ALL OB- Structions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Introducing the Heat & Glo Gas Appliances Pre-install PreparationANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the SL-750TRS-IPI-D GAS Line Electrical Access Diagram of the SL-350TRS-C AccessLocating the Appliance Constructing the Appliance ChaseClearance Requirements Framing the Appliance Framing Dimensions34.93mm AT Each Joint 47 3/4 System Configuration Installing the Vent SystemIdentifying Vent Components SL D-SERIES Components in ANY VentStraight UP Vertical Venting Flex VentWith TWO 900 Elbows Venting with One 90 Elbow Use SL D-Series components only Use DVP-Series Components onlyVenting with Two 90 Elbows Venting with TWO 2 90 o Elbows MAX. = 16 FT 4.8m + V 1 + H MAX. = 40 FT 12.2m Venting with Three 90 elbows Venting with Three 3 90 o Elbows + H 1 MAX. = 16 FT 4.8m + V 1 + H + H MAX. = 40 FT 12.2m Venting with Four 90 elbows DVP Series Venting Only Go to Install FirestopsAttach the First Vent Component to the Starting Collars SL-D and SL-Flex Series Venting OnlyHole and Vent Pipe DVP, SL-D and SL-Flex Series VentingSL-Series Venting Only Vent TerminationFor DVP Venting Only For All VentingVent Termination Minimum Clearances Alcove ApplicationsMinimum Height from Roof to Lowest Discharge Opening Gas Control Systems Positioning, Leveling, and Securing the ApplianceStanding Pilot Ignition System Millivolt SystemGas Pressure Requirements Gas Supply LinePressure Natural Gas Propane For Standing Pilot Ignition Wiring Appliance Requirements Wiring the ApplianceOptional Accessories Wall SwitchIntermittent Pilot Ignition IPI Wiring Diagram Operation using Battery PowerNER FinishingShutter Settings Installing the TrimGlass Specifications Positioning the LogsDouble-check for faulty components After the InstallationBefore Lighting the Appliance Lighting the ApplianceImportant Turn OFF the GAS Before Servicing Your Appliance Appliance Maintenance