Heat & Glo LifeStyle SL-750TRS-IPI-D owner manual Table of Contents

Page 3

TABLE OF CONTENTS

 

Safety and Warning Information

2

ÎService Parts Lists

4

Section 1: Approvals and Codes

12

Appliance Certification

12

Installation Codes

12

High Altitude Installations

12

Î Requirements for the Commonwealth of Massachusetts

13

Section 2: Getting Started

14

Introducing the Heat & Glo Gas Appliances

14

Pre-installation Preparation

14

Section 3: Installing the Appliance

18

Constructing the Appliance Chase

18

Step 1

Locating the Appliance

18

Step 2

Framing the Appliance

19

Step 3

Installing the Vent System

22

 

A. Vent System Approvals

22

 

B. Installing Vent Components

32

 

C. Vent Termination

35

Step 4

Positioning, Leveling, and

 

 

Securing the Appliance

38

Step 5

The Gas Control Systems

38

Step 6

The Gas Supply Line

39

Step 7

Gas Pressure Requirements

39

Step 8

Wiring the Appliance

40

Step 9

Finishing

42

Step 10

Installing Trim, Logs, and Ember Material

43

 

Installing the Trim

43

 

Positioning the Logs

43

 

Shutter Settings

43

 

Placing the Ember Material

43

 

Glass Specifications

43

Step 11 Before Lighting the Appliance

44

Step 12

Lighting the Appliance

44

After the Installation

44

Section 4: Maintaining and Servicing Your Appliance

45

 

Î= Contains updated information.

 

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06

3

Image 3
Contents SL-750TRS-IPI-D SL-550TRS-IPI-D SL-350TRS-C Installation and OperationSafety and Warning Information Table of Contents SL-350TRS-C Log Set AssemblySL-350TRS-C NG, LP Service Parts ListStanding Pilot Ignition Valve AssemblySL-550TRS-IPI-D SL-550TRS-IPI-D Part number list on following Log Set AssemblySL-750TRS-IPI-D Intermittent Pilot Ignition Valve Assembly Service Parts SL-750TRS-IPI-D, SL-550TRS-IPI-DCertification High Altitude InstallationsInstallation Codes Appliance CertificationRequirements for the Commonwealth of Massachusetts Vent Directly BELOW. Keep Clear of ALL OB- StructionsManufacturer Requirements Pre-install Preparation Introducing the Heat & Glo Gas AppliancesANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the SL-750TRS-IPI-D GAS Line Electrical Access Diagram of the SL-350TRS-C AccessConstructing the Appliance Chase Locating the ApplianceClearance Requirements Framing the Appliance Framing Dimensions34.93mm AT Each Joint 47 3/4 SL D-SERIES Components in ANY Vent Installing the Vent SystemSystem Configuration Identifying Vent ComponentsFlex Vent Straight UP Vertical VentingWith TWO 900 Elbows Venting with One 90 Elbow Use SL D-Series components only Use DVP-Series Components onlyVenting with Two 90 Elbows Venting with TWO 2 90 o Elbows MAX. = 16 FT 4.8m + V 1 + H MAX. = 40 FT 12.2m Venting with Three 90 elbows Venting with Three 3 90 o Elbows + H 1 MAX. = 16 FT 4.8m + V 1 + H + H MAX. = 40 FT 12.2m Venting with Four 90 elbows DVP Series Venting Only Go to Install FirestopsAttach the First Vent Component to the Starting Collars SL-D and SL-Flex Series Venting OnlyHole and Vent Pipe DVP, SL-D and SL-Flex Series VentingFor All Venting Vent TerminationSL-Series Venting Only For DVP Venting OnlyVent Termination Minimum Clearances Alcove ApplicationsMinimum Height from Roof to Lowest Discharge Opening Millivolt System Positioning, Leveling, and Securing the ApplianceGas Control Systems Standing Pilot Ignition SystemGas Supply Line Gas Pressure RequirementsPressure Natural Gas Propane Wall Switch Wiring the ApplianceFor Standing Pilot Ignition Wiring Appliance Requirements Optional AccessoriesIntermittent Pilot Ignition IPI Wiring Diagram Operation using Battery PowerNER FinishingPositioning the Logs Installing the TrimShutter Settings Glass SpecificationsLighting the Appliance After the InstallationDouble-check for faulty components Before Lighting the ApplianceImportant Turn OFF the GAS Before Servicing Your Appliance Appliance Maintenance