Heat & Glo LifeStyle SL-750TRS-IPI-D Installing the Trim, Positioning the Logs, Shutter Settings

Page 43

Step 10. Installing Trim, Logs and Ember Material, and Removing Shipping Support

Installing the Trim

Combustible materials may be brought up to the specified clearances on the side and top front edges of the appliance, but MUST NEVER overlap onto the front face. The joints between the finished wall and the appliance top and sides can only be sealed with a 300° F. (149° C) minimum sealant.

!WARNING: WHEN FINISHING THE APPLIANCE, NEVER OBSTRUCT OR MODIFY THE AIR INLET/ OUTLET GRILLES IN ANY MANNER.

Install optional marble and brass trim surround kits as desired. Marble, brass, brick, tile, or other non-combustible materials can be used to cover up the gap between the sheet rock and the appliance.

Do not obstruct or modify the air inlet/outlet grilles. When overlapping on both sides, leave enough space so that the bottom grille can be opened and the trim door removed.

Positioning the Logs

If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately, refer to the instructions that accompany the logs. Save the log instructions with this manual.

If sooting occurs, the logs might need to be repositioned slightly to avoid excessive flame impingement.

Shutter Settings

MODEL

TOP VENTED

REAR VENTED

SL-350TRS-C

1/4” open

3/16” open

SL-350TRS-C-LP

1/2” open

3/8” open

SL-550TRS-IPI-D

1/2” open

1/2” open

SL-550TRSLPIPID

Full open

Full open

SL-750TRS-IPI-D

1/2” open

1/2” open

SL-750TRSLPIPID

Full open

Full open

 

 

 

Placing the Ember Material

The bag labeled Mystic Embers is standard glowing ember material. To place the ember material:

Unlatch the latches at the top and bottom of the glass door.

Remove the glass door from the unit (see Figure 40).

LATCHES

(BOTH TOP

AND BOTTOM)

GLASS

ASSEMBLY

Figure 40. Glass Assembly

GLASS SPECIFICATIONS:

 

SL-750TRS-IPI-D

CERAMIC

SL-550TRS-IPI-D

CERAMIC

SL-350TRS-C

CERAMIC

Place Mystic Embers on base pan on both sides of the burner. Do NOT place on burner top.

Glowing embers can only be placed as shown around the front burner ports. Do NOT cover burner ports (see Figure 41).

EMBERS

Figure 41

• Reinstall and latch the glass door.

CAUTION: THE GLASS DOOR MUST BE SECURELY LATCHED BEFORE OPERATING THE UNIT.

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06

43

Image 43
Contents SL-750TRS-IPI-D SL-550TRS-IPI-D SL-350TRS-C Installation and OperationSafety and Warning Information Table of Contents SL-350TRS-C Log Set AssemblySL-350TRS-C NG, LP Service Parts ListStanding Pilot Ignition Valve AssemblySL-550TRS-IPI-D SL-550TRS-IPI-D Part number list on following Log Set AssemblySL-750TRS-IPI-D Intermittent Pilot Ignition Valve Assembly Service Parts SL-750TRS-IPI-D, SL-550TRS-IPI-DCertification High Altitude InstallationsInstallation Codes Appliance CertificationVent Directly BELOW. Keep Clear of ALL OB- Structions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Introducing the Heat & Glo Gas Appliances Pre-install PreparationANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the SL-750TRS-IPI-D GAS Line Electrical Access Diagram of the SL-350TRS-C AccessLocating the Appliance Constructing the Appliance ChaseClearance Requirements Framing the Appliance Framing Dimensions34.93mm AT Each Joint 47 3/4 SL D-SERIES Components in ANY Vent Installing the Vent SystemSystem Configuration Identifying Vent ComponentsStraight UP Vertical Venting Flex VentWith TWO 900 Elbows Venting with One 90 Elbow Use SL D-Series components only Use DVP-Series Components onlyVenting with Two 90 Elbows Venting with TWO 2 90 o Elbows MAX. = 16 FT 4.8m + V 1 + H MAX. = 40 FT 12.2m Venting with Three 90 elbows Venting with Three 3 90 o Elbows + H 1 MAX. = 16 FT 4.8m + V 1 + H + H MAX. = 40 FT 12.2m Venting with Four 90 elbows DVP Series Venting Only Go to Install FirestopsAttach the First Vent Component to the Starting Collars SL-D and SL-Flex Series Venting OnlyHole and Vent Pipe DVP, SL-D and SL-Flex Series VentingFor All Venting Vent TerminationSL-Series Venting Only For DVP Venting OnlyVent Termination Minimum Clearances Alcove ApplicationsMinimum Height from Roof to Lowest Discharge Opening Millivolt System Positioning, Leveling, and Securing the ApplianceGas Control Systems Standing Pilot Ignition SystemGas Pressure Requirements Gas Supply LinePressure Natural Gas Propane Wall Switch Wiring the ApplianceFor Standing Pilot Ignition Wiring Appliance Requirements Optional AccessoriesIntermittent Pilot Ignition IPI Wiring Diagram Operation using Battery PowerNER FinishingPositioning the Logs Installing the TrimShutter Settings Glass SpecificationsLighting the Appliance After the InstallationDouble-check for faulty components Before Lighting the ApplianceImportant Turn OFF the GAS Before Servicing Your Appliance Appliance Maintenance