Heat & Glo LifeStyle SL-750TRS-IPI-D owner manual Venting with Three 90 elbows

Page 28

V

H

H + H1

1' MIN. (305 mm)

2' MAX. (610mm)

4' MAX. (1.22m)

2' MIN. (610 mm)

4' MAX. (1.22m)

8' MAX. (2.48m)

3' MIN. (914 mm)

6' MAX. (1.86m)

12' MAX. (3.72m)

4' MIN. (1.22 m)

8' MAX. (2.48m)

16' MAX. (4.8m)

V1+V+H+H1 = 40' MAX. (12.4m)

H = 8' MAX. (2.48m) H+H1 =16' MAX. (4.8m)

V1

V

H1

H

V

 

 

H

 

 

H + H1 + H2

1' MIN. (305 mm)

2' MAX. (610 mm)

4' MAX. (1.22m)

2' MIN. (610 mm)

4' MAX. (1.22 m)

8' MAX. (2.48m)

 

3' MIN. (914 mm)

6' MAX. (1.86 m)

12' MAX. (3.72m)

 

4' MIN. (1.22 m)

8' MAX. (2.48 m)

16' MAX. (4.8m)

 

V+H+H +H

2

= 40' MAX. (12.4 m)

 

 

 

 

1

 

H + H + H

 

= 16' MAX. (4.8m)

 

H = 8' MAX. (2.48m)

2

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

V

H2

H1

Use DVP-Series components only.

H

Figure 17. Venting with Three 90° elbows

28

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06

Image 28
Contents Installation and Operation SL-750TRS-IPI-D SL-550TRS-IPI-D SL-350TRS-CSafety and Warning Information Table of Contents Log Set Assembly SL-350TRS-CNG, LP Service Parts List SL-350TRS-CValve Assembly Standing Pilot IgnitionSL-550TRS-IPI-D SL-550TRS-IPI-D Log Set Assembly Part number list on followingSL-750TRS-IPI-D Service Parts SL-750TRS-IPI-D, SL-550TRS-IPI-D Intermittent Pilot Ignition Valve AssemblyHigh Altitude Installations Installation CodesAppliance Certification CertificationVent Directly BELOW. Keep Clear of ALL OB- Structions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Introducing the Heat & Glo Gas Appliances Pre-install PreparationANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the SL-750TRS-IPI-D GAS Line Electrical Access Access Diagram of the SL-350TRS-CLocating the Appliance Constructing the Appliance ChaseClearance Requirements Framing Dimensions Framing the Appliance34.93mm AT Each Joint 47 3/4 Installing the Vent System System ConfigurationIdentifying Vent Components SL D-SERIES Components in ANY VentStraight UP Vertical Venting Flex VentWith TWO 900 Elbows Use DVP-Series Components only Venting with One 90 Elbow Use SL D-Series components onlyVenting with Two 90 Elbows Venting with TWO 2 90 o Elbows MAX. = 16 FT 4.8m + V 1 + H MAX. = 40 FT 12.2m Venting with Three 90 elbows Venting with Three 3 90 o Elbows + H 1 MAX. = 16 FT 4.8m + V 1 + H + H MAX. = 40 FT 12.2m Venting with Four 90 elbows Go to Install Firestops DVP Series Venting OnlySL-D and SL-Flex Series Venting Only Attach the First Vent Component to the Starting CollarsDVP, SL-D and SL-Flex Series Venting Hole and Vent PipeVent Termination SL-Series Venting OnlyFor DVP Venting Only For All VentingAlcove Applications Vent Termination Minimum ClearancesMinimum Height from Roof to Lowest Discharge Opening Positioning, Leveling, and Securing the Appliance Gas Control SystemsStanding Pilot Ignition System Millivolt SystemGas Pressure Requirements Gas Supply LinePressure Natural Gas Propane Wiring the Appliance For Standing Pilot Ignition Wiring Appliance RequirementsOptional Accessories Wall SwitchOperation using Battery Power Intermittent Pilot Ignition IPI Wiring DiagramFinishing NERInstalling the Trim Shutter SettingsGlass Specifications Positioning the LogsAfter the Installation Double-check for faulty componentsBefore Lighting the Appliance Lighting the ApplianceAppliance Maintenance Important Turn OFF the GAS Before Servicing Your Appliance