Step 4. Positioning, Leveling, and Securing the Appliance

The diagram below shows how to properly position, level, and secure the appliance.

WARNING:

To ensure proper clearances the front framing header must be installed on its narrow edge and to the front of the frame.

NAILING TABS (BOTH SIDES)

Figure 32. Proper Positioning, Leveling, and

Securing of a Appliance

Place the appliance into position.

Level the appliance from side to side and from front to back.

Shim the appliance with non-combustible material, such as sheet metal, as necessary.

Secure the appliance to the framing using nails or screws through the nailing tabs.

Step 5. The Gas Control Systems

!WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

The two types of gas control systems used with this model: Standing Pilot Ignition and Intellifire Pilot Ignition (IPI).

Standing Pilot Ignition System

This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor.

WARNING: 110-120 VAC MUST NEVER BE ! CONNECTED TO A CONTROL VALVE IN A

MILLIVOLT SYSTEM.

STANDING PILOT

Figure 33. Gas Control Systems

Intellifire Pilot Ignition (IPI) System

This system includes a 3V control valve, electronic module and intermittent pilot.

!WARNING: CONTINUOUS 110-120 VAC SERVICE MUST BE WIRED DIRECTLY TO

THE APPLIANCE JUNCTION BOX IN A IPI SYSTEM.

38

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06

Image 38
Contents Installation and Operation SL-750TRS-IPI-D SL-550TRS-IPI-D SL-350TRS-CSafety and Warning Information Table of Contents Log Set Assembly SL-350TRS-CNG, LP Service Parts List SL-350TRS-CValve Assembly Standing Pilot IgnitionSL-550TRS-IPI-D SL-550TRS-IPI-D Log Set Assembly Part number list on followingSL-750TRS-IPI-D Service Parts SL-750TRS-IPI-D, SL-550TRS-IPI-D Intermittent Pilot Ignition Valve AssemblyAppliance Certification High Altitude InstallationsInstallation Codes CertificationManufacturer Requirements Requirements for the Commonwealth of MassachusettsVent Directly BELOW. Keep Clear of ALL OB- Structions ANY Such Action MAY Possibly Cause a Fire Hazard Pre-install PreparationIntroducing the Heat & Glo Gas Appliances Diagram of the SL-750TRS-IPI-D GAS Line Electrical Access Access Diagram of the SL-350TRS-CClearance Requirements Constructing the Appliance ChaseLocating the Appliance Framing Dimensions Framing the Appliance34.93mm AT Each Joint 47 3/4 Identifying Vent Components Installing the Vent SystemSystem Configuration SL D-SERIES Components in ANY VentWith TWO 900 Elbows Flex VentStraight UP Vertical Venting Use DVP-Series Components only Venting with One 90 Elbow Use SL D-Series components onlyVenting with Two 90 Elbows Venting with TWO 2 90 o Elbows MAX. = 16 FT 4.8m + V 1 + H MAX. = 40 FT 12.2m Venting with Three 90 elbows Venting with Three 3 90 o Elbows + H 1 MAX. = 16 FT 4.8m + V 1 + H + H MAX. = 40 FT 12.2m Venting with Four 90 elbows Go to Install Firestops DVP Series Venting OnlySL-D and SL-Flex Series Venting Only Attach the First Vent Component to the Starting CollarsDVP, SL-D and SL-Flex Series Venting Hole and Vent PipeFor DVP Venting Only Vent TerminationSL-Series Venting Only For All VentingAlcove Applications Vent Termination Minimum ClearancesMinimum Height from Roof to Lowest Discharge Opening Standing Pilot Ignition System Positioning, Leveling, and Securing the ApplianceGas Control Systems Millivolt SystemPressure Natural Gas Propane Gas Supply LineGas Pressure Requirements Optional Accessories Wiring the ApplianceFor Standing Pilot Ignition Wiring Appliance Requirements Wall SwitchOperation using Battery Power Intermittent Pilot Ignition IPI Wiring DiagramFinishing NERGlass Specifications Installing the TrimShutter Settings Positioning the LogsBefore Lighting the Appliance After the InstallationDouble-check for faulty components Lighting the ApplianceAppliance Maintenance Important Turn OFF the GAS Before Servicing Your Appliance