VENTING WITH TWO (2) 90o ELBOWS

NATURAL GAS

 

MODEL: SL-350TRS-C MODELS: SL-550TRS-D, SL-750TRS-D

V (MIN.)

H + H1 (MAX.)

H + H1 (MAX.)

90o Elbow on Top

2.5 FT (762mm)

2 FT (610mm)

1 FT (305mm)

3 FT (914mm)

3 FT (914mm)

2 FT (610mm)

4 FT (1.22m)

4 FT (1.22m)

3 FT (914mm)

6 FT (1.86m)

6 FT (1.86m)

4 FT (1.22m)

8 FT (2.48m)

8 FT (2.48m)

5 FT (1.52m)

16 FT (4.8m)

16 FT (4.8m)

H + H1 MAX. = 16 FT (4.8m)

V + H + H1

MAX. = 40 FT (12.2m)

 

 

 

 

VENTING WITH TWO (2) 90o ELBOWS

PROPANE

MODELS: SL-350TRS-C, SL-550TRS-D, SL-750TRS-D

V (MIN.)

H + H1 (MAX.)

90o Elbow on Top

NOTALLOWED

1 FT (305mm)

2 FT (610mm)

 

2 FT (610mm)

4 FT (1.22m)

 

3 FT (914mm)

6 FT (1.86m)

 

4 FT (1.22m)

8 FT (2.48m)

 

5 FT (1.52m)

16 FT (4.8m)

 

H + H1 MAX. = 16 FT (4.8m)

V + H + H1 MAX. = 40 FT (12.2m)

 

 

 

H1

V

H

NOTE: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installa- tion (see Figure 9).

Use SL D-Series components only.

Figure 15. Venting with Two 90° Elbows

26

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06

Image 26
Contents Installation and Operation SL-750TRS-IPI-D SL-550TRS-IPI-D SL-350TRS-CSafety and Warning Information Table of Contents Log Set Assembly SL-350TRS-CNG, LP Service Parts List SL-350TRS-CValve Assembly Standing Pilot IgnitionSL-550TRS-IPI-D SL-550TRS-IPI-D Log Set Assembly Part number list on followingSL-750TRS-IPI-D Service Parts SL-750TRS-IPI-D, SL-550TRS-IPI-D Intermittent Pilot Ignition Valve AssemblyAppliance Certification High Altitude InstallationsInstallation Codes CertificationManufacturer Requirements Requirements for the Commonwealth of MassachusettsVent Directly BELOW. Keep Clear of ALL OB- Structions ANY Such Action MAY Possibly Cause a Fire Hazard Pre-install PreparationIntroducing the Heat & Glo Gas Appliances Diagram of the SL-750TRS-IPI-D GAS Line Electrical Access Access Diagram of the SL-350TRS-CClearance Requirements Constructing the Appliance ChaseLocating the Appliance Framing Dimensions Framing the Appliance34.93mm AT Each Joint 47 3/4 Identifying Vent Components Installing the Vent SystemSystem Configuration SL D-SERIES Components in ANY VentWith TWO 900 Elbows Flex VentStraight UP Vertical Venting Use DVP-Series Components only Venting with One 90 Elbow Use SL D-Series components onlyVenting with Two 90 Elbows Venting with TWO 2 90 o Elbows MAX. = 16 FT 4.8m + V 1 + H MAX. = 40 FT 12.2m Venting with Three 90 elbows Venting with Three 3 90 o Elbows + H 1 MAX. = 16 FT 4.8m + V 1 + H + H MAX. = 40 FT 12.2m Venting with Four 90 elbows Go to Install Firestops DVP Series Venting OnlySL-D and SL-Flex Series Venting Only Attach the First Vent Component to the Starting CollarsDVP, SL-D and SL-Flex Series Venting Hole and Vent PipeFor DVP Venting Only Vent TerminationSL-Series Venting Only For All VentingAlcove Applications Vent Termination Minimum ClearancesMinimum Height from Roof to Lowest Discharge Opening Standing Pilot Ignition System Positioning, Leveling, and Securing the ApplianceGas Control Systems Millivolt SystemPressure Natural Gas Propane Gas Supply LineGas Pressure Requirements Optional Accessories Wiring the ApplianceFor Standing Pilot Ignition Wiring Appliance Requirements Wall SwitchOperation using Battery Power Intermittent Pilot Ignition IPI Wiring DiagramFinishing NERGlass Specifications Installing the TrimShutter Settings Positioning the LogsBefore Lighting the Appliance After the InstallationDouble-check for faulty components Lighting the ApplianceAppliance Maintenance Important Turn OFF the GAS Before Servicing Your Appliance