22-3/4 [577]

 

 

 

 

 

11-3/8 [289]

1/2[13]

 

 

 

 

 

 

 

 

 

 

15-7/8

[402]

 

16-1/4

 

 

 

8-3/4 [413]

 

 

 

 

 

 

 

 

 

 

[223]

 

ø8 [203]

 

 

 

 

 

 

 

 

 

ø 6-5/8 [168.3]

 

 

 

 

34-1/2

 

2-1/8 30-1/2

15-1/4

29

3-1/2

30-5/8

[876]

 

[388]

[90]

[777]

 

 

[55]

[776]

 

[737]

 

21-1/4

 

 

 

 

 

 

 

[540]

GAS LINE

 

 

28-1/8

6-7/8

ELECTRICAL

ACCESS

 

6

[714]

ACCESS

 

 

 

33

[174]

 

 

 

[153]

 

 

 

[836]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOP STANDOFFS

 

 

 

 

 

 

 

 

 

 

VENT COLLARS

 

 

 

 

HOOD

 

 

 

 

 

 

 

CERAMIC

 

 

 

 

 

 

 

FIBER PAD

 

 

 

 

 

 

 

RATING PLATES

 

 

 

 

 

 

 

& LABELS

 

 

 

GAS LINE

 

 

GAS

BOTTOM GRILLE

 

ELECTRICAL

 

 

COVER

 

ACCESS

 

 

CONTROLS

 

ACCESS

 

 

 

 

 

Figure 3.

Diagram of the SL-350TRS-C

 

 

 

 

 

 

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06

17

Image 17
Contents SL-750TRS-IPI-D SL-550TRS-IPI-D SL-350TRS-C Installation and OperationSafety and Warning Information Table of Contents SL-350TRS-C Log Set AssemblySL-350TRS-C NG, LP Service Parts ListStanding Pilot Ignition Valve AssemblySL-550TRS-IPI-D SL-550TRS-IPI-D Part number list on following Log Set AssemblySL-750TRS-IPI-D Intermittent Pilot Ignition Valve Assembly Service Parts SL-750TRS-IPI-D, SL-550TRS-IPI-DInstallation Codes High Altitude InstallationsAppliance Certification CertificationManufacturer Requirements Requirements for the Commonwealth of MassachusettsVent Directly BELOW. Keep Clear of ALL OB- Structions ANY Such Action MAY Possibly Cause a Fire Hazard Pre-install PreparationIntroducing the Heat & Glo Gas Appliances Diagram of the SL-750TRS-IPI-D GAS Line Electrical Access Diagram of the SL-350TRS-C AccessClearance Requirements Constructing the Appliance ChaseLocating the Appliance Framing the Appliance Framing Dimensions34.93mm AT Each Joint 47 3/4 System Configuration Installing the Vent SystemIdentifying Vent Components SL D-SERIES Components in ANY VentWith TWO 900 Elbows Flex VentStraight UP Vertical Venting Venting with One 90 Elbow Use SL D-Series components only Use DVP-Series Components onlyVenting with Two 90 Elbows Venting with TWO 2 90 o Elbows MAX. = 16 FT 4.8m + V 1 + H MAX. = 40 FT 12.2m Venting with Three 90 elbows Venting with Three 3 90 o Elbows + H 1 MAX. = 16 FT 4.8m + V 1 + H + H MAX. = 40 FT 12.2m Venting with Four 90 elbows DVP Series Venting Only Go to Install FirestopsAttach the First Vent Component to the Starting Collars SL-D and SL-Flex Series Venting OnlyHole and Vent Pipe DVP, SL-D and SL-Flex Series VentingSL-Series Venting Only Vent TerminationFor DVP Venting Only For All VentingVent Termination Minimum Clearances Alcove ApplicationsMinimum Height from Roof to Lowest Discharge Opening Gas Control Systems Positioning, Leveling, and Securing the ApplianceStanding Pilot Ignition System Millivolt SystemPressure Natural Gas Propane Gas Supply LineGas Pressure Requirements For Standing Pilot Ignition Wiring Appliance Requirements Wiring the ApplianceOptional Accessories Wall SwitchIntermittent Pilot Ignition IPI Wiring Diagram Operation using Battery PowerNER FinishingShutter Settings Installing the TrimGlass Specifications Positioning the LogsDouble-check for faulty components After the InstallationBefore Lighting the Appliance Lighting the ApplianceImportant Turn OFF the GAS Before Servicing Your Appliance Appliance Maintenance