Heat & Glo LifeStyle SL-750TRS-IPI-D owner manual 47 3/4

Page 21

 

6 1/2

6 3/8

 

 

 

 

 

 

 

 

9 1/4

 

 

 

 

 

 

 

 

6 1/2

9 5/8

 

 

 

 

 

 

 

 

6 3/8

 

 

 

6 5/8

 

 

 

 

 

 

SL-45D

6 5/8

 

 

 

 

 

 

 

 

 

 

 

9 5/8

 

 

 

 

 

SL-90D

 

 

SL-09D

SL-12/17D (SL12-17D)

SL-24D

SL-36D

 

SL-48D

8 3/4

 

 

 

 

 

 

12-17

 

 

 

 

 

23 3/4

 

 

 

 

 

 

 

35 3/4

 

 

 

 

 

 

47 3/4

 

17-24

 

 

 

 

 

 

 

 

6 1/2

 

 

 

11 3/4

 

 

 

 

 

5 3/4

 

 

 

 

SL-17/24D

 

 

6 5/8

 

 

SL-12D

SL-06D

 

 

 

(SL17-24D)

 

 

 

SL-FLEX-10

 

 

 

 

 

 

120”

 

 

 

 

 

(3048mm)

 

 

 

 

SL-FLEX-5

 

 

 

SL-FLEX-2

 

 

 

 

 

 

 

60”

 

 

24”

 

 

(1524mm)

 

 

 

 

 

 

(610mm)

 

 

 

 

 

 

SL-FLEX-3

 

 

 

 

 

 

36”

 

NOTE: PIPES OVERLAP 1-3/8 INCHES

 

 

(34.93mm) AT EACH JOINT.

 

(914mm)

 

 

Figure 7. SL D-Series Direct Vent Component Specifications

(4-inch inner pipe / 6 5/8-inch outer pipe)

 

 

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06

 

21

Image 21
Contents SL-750TRS-IPI-D SL-550TRS-IPI-D SL-350TRS-C Installation and OperationSafety and Warning Information Table of Contents SL-350TRS-C Log Set AssemblySL-350TRS-C NG, LP Service Parts ListStanding Pilot Ignition Valve AssemblySL-550TRS-IPI-D SL-550TRS-IPI-D Part number list on following Log Set AssemblySL-750TRS-IPI-D Intermittent Pilot Ignition Valve Assembly Service Parts SL-750TRS-IPI-D, SL-550TRS-IPI-DInstallation Codes High Altitude InstallationsAppliance Certification CertificationRequirements for the Commonwealth of Massachusetts Vent Directly BELOW. Keep Clear of ALL OB- StructionsManufacturer Requirements Pre-install Preparation Introducing the Heat & Glo Gas AppliancesANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the SL-750TRS-IPI-D GAS Line Electrical Access Diagram of the SL-350TRS-C AccessConstructing the Appliance Chase Locating the ApplianceClearance Requirements Framing the Appliance Framing Dimensions34.93mm AT Each Joint 47 3/4 System Configuration Installing the Vent SystemIdentifying Vent Components SL D-SERIES Components in ANY VentFlex Vent Straight UP Vertical VentingWith TWO 900 Elbows Venting with One 90 Elbow Use SL D-Series components only Use DVP-Series Components onlyVenting with Two 90 Elbows Venting with TWO 2 90 o Elbows MAX. = 16 FT 4.8m + V 1 + H MAX. = 40 FT 12.2m Venting with Three 90 elbows Venting with Three 3 90 o Elbows + H 1 MAX. = 16 FT 4.8m + V 1 + H + H MAX. = 40 FT 12.2m Venting with Four 90 elbows DVP Series Venting Only Go to Install FirestopsAttach the First Vent Component to the Starting Collars SL-D and SL-Flex Series Venting OnlyHole and Vent Pipe DVP, SL-D and SL-Flex Series VentingSL-Series Venting Only Vent TerminationFor DVP Venting Only For All VentingVent Termination Minimum Clearances Alcove ApplicationsMinimum Height from Roof to Lowest Discharge Opening Gas Control Systems Positioning, Leveling, and Securing the ApplianceStanding Pilot Ignition System Millivolt SystemGas Supply Line Gas Pressure RequirementsPressure Natural Gas Propane For Standing Pilot Ignition Wiring Appliance Requirements Wiring the ApplianceOptional Accessories Wall SwitchIntermittent Pilot Ignition IPI Wiring Diagram Operation using Battery PowerNER FinishingShutter Settings Installing the TrimGlass Specifications Positioning the LogsDouble-check for faulty components After the InstallationBefore Lighting the Appliance Lighting the ApplianceImportant Turn OFF the GAS Before Servicing Your Appliance Appliance Maintenance