Heat & Glo LifeStyle SL-750TRS-IPI-D owner manual Use DVP-Series Components only

Page 24

V

 

H

 

1' MIN. (305mm)

2'

MAX. (610mm)

 

2' MIN. (610mm)

4'

MAX. (1.22m)

 

3' MIN. (914mm)

6'

MAX. (1.86m)

 

4' MIN. (1.22m)

8'

MAX. (2.4m)

 

V+H=40' MAX. (12.4m)

 

 

H = 8' MAX. (2.4m)

 

 

 

 

 

 

V

Use DVP-Series

 

components only.

H

Figure 12. Venting with One 90° Elbow

H

Use SL D-Series components only.

VENTING WITH ONE (1) 90o ELBOW

NATURAL GAS

 

MODEL: SL-350TRS-C MODELS: SL-550TRS-D, SL-750TRS-D

V (MIN.)

H (MAX.)

 

H (MAX.)

90o Elbow on Top

2.5 FT (762mm)

 

2 FT (610mm)

1 FT (305mm)

3 FT (914mm)

 

3 FT (914mm)

2 FT (610mm)

4 FT (1.22m)

 

4 FT (1.22m)

3 FT (914mm)

6 FT (1.86m)

 

6 FT (1.86m)

4 FT (1.22m)

8 FT (2.48m)

 

8 FT (2.48m)

5 FT (1.52m)

16 FT (4.8m)

 

16 FT (4.8m)

H MAX. = 16 FT (4.8m)

V + H MAX. = 40 FT (12.2m)

 

 

 

 

VENTING WITH ONE (1) 90o ELBOW

PROPANE

MODELS: SL-350TRS-C, SL-550TRS-D, SL-750TRS-D

V (MIN.)

H (MAX.)

 

90o Elbow on Top

NOTALLOWED

1 FT (305mm)

2 FT (610mm)

2 FT (610mm)

4 FT (1.22m)

3 FT (914mm)

6 FT (1.86m)

4 FT (1.22m)

8 FT (2.48m)

5 FT (1.52m)

16 FT (4.8m)

H MAX. = 16 FT (4.8m)

V + H MAX. = 40 FT (12.2m)

 

 

 

V

NOTE: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installa- tion (see Figure 9).

Figure 13. Venting with One 90° Elbow

24

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06

Image 24
Contents Installation and Operation SL-750TRS-IPI-D SL-550TRS-IPI-D SL-350TRS-CSafety and Warning Information Table of Contents Log Set Assembly SL-350TRS-CNG, LP Service Parts List SL-350TRS-CValve Assembly Standing Pilot IgnitionSL-550TRS-IPI-D SL-550TRS-IPI-D Log Set Assembly Part number list on followingSL-750TRS-IPI-D Service Parts SL-750TRS-IPI-D, SL-550TRS-IPI-D Intermittent Pilot Ignition Valve AssemblyHigh Altitude Installations Installation CodesAppliance Certification CertificationRequirements for the Commonwealth of Massachusetts Vent Directly BELOW. Keep Clear of ALL OB- StructionsManufacturer Requirements Pre-install Preparation Introducing the Heat & Glo Gas AppliancesANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the SL-750TRS-IPI-D GAS Line Electrical Access Access Diagram of the SL-350TRS-CConstructing the Appliance Chase Locating the ApplianceClearance Requirements Framing Dimensions Framing the Appliance34.93mm AT Each Joint 47 3/4 Installing the Vent System System ConfigurationIdentifying Vent Components SL D-SERIES Components in ANY VentFlex Vent Straight UP Vertical VentingWith TWO 900 Elbows Use DVP-Series Components only Venting with One 90 Elbow Use SL D-Series components onlyVenting with Two 90 Elbows Venting with TWO 2 90 o Elbows MAX. = 16 FT 4.8m + V 1 + H MAX. = 40 FT 12.2m Venting with Three 90 elbows Venting with Three 3 90 o Elbows + H 1 MAX. = 16 FT 4.8m + V 1 + H + H MAX. = 40 FT 12.2m Venting with Four 90 elbows Go to Install Firestops DVP Series Venting OnlySL-D and SL-Flex Series Venting Only Attach the First Vent Component to the Starting CollarsDVP, SL-D and SL-Flex Series Venting Hole and Vent PipeVent Termination SL-Series Venting OnlyFor DVP Venting Only For All VentingAlcove Applications Vent Termination Minimum ClearancesMinimum Height from Roof to Lowest Discharge Opening Positioning, Leveling, and Securing the Appliance Gas Control SystemsStanding Pilot Ignition System Millivolt SystemGas Supply Line Gas Pressure RequirementsPressure Natural Gas Propane Wiring the Appliance For Standing Pilot Ignition Wiring Appliance RequirementsOptional Accessories Wall SwitchOperation using Battery Power Intermittent Pilot Ignition IPI Wiring DiagramFinishing NERInstalling the Trim Shutter SettingsGlass Specifications Positioning the LogsAfter the Installation Double-check for faulty componentsBefore Lighting the Appliance Lighting the ApplianceAppliance Maintenance Important Turn OFF the GAS Before Servicing Your Appliance