Heat & Glo LifeStyle SL-750TRS-IPI-D owner manual NG, LP Service Parts List, SL-350TRS-C

Page 5

(NG, LP) Service Parts List

SL-350TRS-C

IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When order- ing, supply serial and model numbers to ensure correct service parts.

ITEM

STANDING PILOT

 

SERIAL #

PART NUMBER

 

Burner Orifice NG (#43C)

 

 

582-843

 

 

 

 

 

 

 

 

Burner Orifice LP (#53C)

 

 

582-853

 

 

 

 

 

 

1

Glass Door Assembly

 

 

GLA-350TRS

 

 

 

 

 

 

2

Burner NG, LP

 

 

540-234A

 

 

 

 

 

 

 

3

Mesh Panel Door

 

 

540-382A

 

 

 

 

 

 

 

4

Log Grate

 

 

540-361A

 

 

 

 

 

 

 

5

Base Refractory

PRE

4/06

540-206T

(Tan)

POST

4/06

2065-206

(Black)

 

 

6

Hood

 

 

SRV540-174

 

 

 

 

 

 

7

Log Set Assembly

 

 

LOGS-350

 

 

 

 

 

 

8

Log 1

 

 

SRV530-701

 

 

 

 

 

9

Log 2

 

 

SRV530-704

 

 

 

 

 

10

Log 3

 

 

SRV540-702

 

 

 

 

 

11

Log 4

 

 

SRV530-705

 

 

 

 

 

12

Log 5

 

 

SRV530-703

 

 

 

 

 

 

13

Junction Box

PRE

00251404

100-250A

 

POST

00251404

4021-013

 

 

 

 

14

Louver, Top

 

 

540-256A

 

 

 

 

 

 

 

15

Louver, Bottom

 

 

540-257A

 

 

 

 

 

 

 

 

Pilot Orifice NG

 

 

446-505

 

 

 

 

 

 

 

 

Pilot Orifice LP

 

 

446-517

 

 

 

 

 

 

 

 

Thermocouple

 

 

446-511

 

 

 

 

 

 

 

 

Thermopile

 

 

060-512

 

 

 

 

 

 

 

Conversion Kit NG

 

 

NGK-350TRS-C

 

 

 

 

 

 

Conversion Kit LP

 

 

LPK-350TRS-C

 

 

 

 

 

 

Vermiculite Embers

 

 

MYSTIC-EMBERS

 

 

 

 

 

 

 

Exhaust Restrictor

 

 

530-299

 

 

 

 

 

 

 

 

Glass Latch Assembly

 

 

386-122A

 

 

 

 

 

 

 

 

Mineral Wool

 

 

050-721

 

 

 

 

 

 

 

Touch up Paint

 

 

TUP-GBK-12

 

 

 

 

 

 

Also see additional pages for valve assembly service part numbers.

Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D2065-985 Rev. J • 5/06

5

Image 5
Contents SL-750TRS-IPI-D SL-550TRS-IPI-D SL-350TRS-C Installation and OperationSafety and Warning Information Table of Contents SL-350TRS-C Log Set AssemblySL-350TRS-C NG, LP Service Parts ListStanding Pilot Ignition Valve AssemblySL-550TRS-IPI-D SL-550TRS-IPI-D Part number list on following Log Set AssemblySL-750TRS-IPI-D Intermittent Pilot Ignition Valve Assembly Service Parts SL-750TRS-IPI-D, SL-550TRS-IPI-DInstallation Codes High Altitude InstallationsAppliance Certification CertificationManufacturer Requirements Requirements for the Commonwealth of MassachusettsVent Directly BELOW. Keep Clear of ALL OB- Structions ANY Such Action MAY Possibly Cause a Fire Hazard Pre-install PreparationIntroducing the Heat & Glo Gas Appliances Diagram of the SL-750TRS-IPI-D GAS Line Electrical Access Diagram of the SL-350TRS-C AccessClearance Requirements Constructing the Appliance ChaseLocating the Appliance Framing the Appliance Framing Dimensions34.93mm AT Each Joint 47 3/4 System Configuration Installing the Vent SystemIdentifying Vent Components SL D-SERIES Components in ANY VentWith TWO 900 Elbows Flex VentStraight UP Vertical Venting Venting with One 90 Elbow Use SL D-Series components only Use DVP-Series Components onlyVenting with Two 90 Elbows Venting with TWO 2 90 o Elbows MAX. = 16 FT 4.8m + V 1 + H MAX. = 40 FT 12.2m Venting with Three 90 elbows Venting with Three 3 90 o Elbows + H 1 MAX. = 16 FT 4.8m + V 1 + H + H MAX. = 40 FT 12.2m Venting with Four 90 elbows DVP Series Venting Only Go to Install FirestopsAttach the First Vent Component to the Starting Collars SL-D and SL-Flex Series Venting OnlyHole and Vent Pipe DVP, SL-D and SL-Flex Series VentingSL-Series Venting Only Vent TerminationFor DVP Venting Only For All VentingVent Termination Minimum Clearances Alcove ApplicationsMinimum Height from Roof to Lowest Discharge Opening Gas Control Systems Positioning, Leveling, and Securing the ApplianceStanding Pilot Ignition System Millivolt SystemPressure Natural Gas Propane Gas Supply LineGas Pressure Requirements For Standing Pilot Ignition Wiring Appliance Requirements Wiring the ApplianceOptional Accessories Wall SwitchIntermittent Pilot Ignition IPI Wiring Diagram Operation using Battery PowerNER FinishingShutter Settings Installing the TrimGlass Specifications Positioning the LogsDouble-check for faulty components After the InstallationBefore Lighting the Appliance Lighting the ApplianceImportant Turn OFF the GAS Before Servicing Your Appliance Appliance Maintenance