Gas-Fired Products PTS Series, PTU Series manual Body Components, Description

Page 54

BODY COMPONENTS

ITEM

PART NO.

DESCRIPTION

1

02266010

Reflector Speed Clip

2

43980010

Wire Hanger

3

42873000

“U” Bolt Clamp, 4” OD Tube

3a

02127110

5/16-18 Hex Nut (2 per “U” Bolt)

4

43318000

Tube Support/Hanger Bracket, 13”

5

43319050

Reflector, 4’-11½” long (5’ section only; 1 per 5 ft. body section)

6

43319100

Reflector, 9’-11½” long (10’ section only; 1 per 10 ft. body section)

7

43320000

End Reflector (optional)

8

43342000

Corner Reflector Package (optional)

9

42921000

Tube Flange Gasket

10*

44028170

10’ Tube Assembly Kit, 4” OD, ATC steel with one 6-hole flange (start tube)

10a**

44028030

10’ Tube Assembly Kit, 4” OD, ALC steel with one 24-hole flange (start tube)

11

44028100

10’ Tube Assembly Kit, 4” OD, HRS steel without flanges (extension tube & exhaust tube)

11a

44028060

10’ Tube Assembly Kit, 4” OD, ALC steel without flanges (extension tube & exhaust tube)

12

44028120

5’ Tube Assembly Kit, 4” OD, HRS steel without flanges (extension tube & exhaust tube)

12a

44028010

5’ Tube Assembly Kit, 4” OD, ALC steel without flanges (extension tube & exhaust tube)

13

43208010

4” O.D. Elbow Package

14

02189020

#10 x ½” Self-Drilling Screw

15

30462980

4” OD Tube Compression Coupling w/bolts

16

43208020

4” OD U-Bend(Required for PTU Only)

17

43488000

U-Bend Reflector (PTU Option)

18

30504500

Flue Adapter Collar

19

44152240

Turbulator (see specifications section 5.0 for quantities)

*Required on 40ft, 50ft, 60ft and 70ft systems for mounting of control box.

**Required on 10ft, 20ft and 30ft systems for mounting of control box.

17

 

 

 

8

 

 

 

 

1

 

 

 

 

16

 

 

 

 

 

 

 

 

 

5

 

6

 

 

3

 

 

 

13

 

 

 

 

 

 

 

 

 

14,15

14,15

4

1

 

 

 

 

 

2

 

3a

7

 

 

 

 

12,12a

 

 

 

 

5 FT

 

 

 

10,10a,11,11a

 

BODY COMPONENTS

2

 

 

 

 

 

 

 

 

 

 

19

7

3

 

 

 

14,18

1

 

 

 

 

410 FT

BODY COMPONENTS

93a

ALL ILLUSTRATIONS ARE INTENDED TO GIVE THE GENERAL IMPRESSION OF UNITS ONLY. OTHER COMBINATIONS OF 5 FT. AND 10 FT. SECTIONS, AND ONES WITH OR WITHOUT THE ELBOW PACKAGE ARE POSSIBLE. PLEASE CONSULT WITH YOUR Space-Ray SALES REPRESENTATIVE. WE RESERVE THE RIGHT TO ALTER ANY SPECIFICATION WITHOUT NOTICE.

Form #43343330

 

May 08

–53–

Image 54
Contents Installation and Operation Instructions Table of Contents Installation Requirements SafetyInstaller Responsibility General InformationFor Canada only High AltitudeMinimum Clearances to Combustibles Minimum Clearances to CombustiblesPTS/PTU Specifications Packing ListBurner Package Numbers Natural GASPTU 40-200 Body Package Descriptions Reflector, 4’ 11 ½’ Accessories End Reflector Accessory PackageExhaust Hood Package Typical Layouts PTU / PTS Series Emitter Length Body Length ModelTypical Assembly Layout Poisonous GAS and Soot HazardPTS Series Dimensions PTU Series Heater Assembly Joining of Tube SectionsTypical Assembly Overview PTU 40FT Shown Typical Suspension Methods Suspension HazardAssembly of Tube Sections CUT HazardAssembly of Extension Section MIN 8’ MAX 10’ Between HangersInserting Turbulators Assembly Hazard Adding ReflectorsAdding Optional 90º Elbow PTS only Adding Optional Corner Reflector PTS onlyAdding 180U-Bend PTU only Adding Optional U-BEND Reflector PTU onlyAttaching Burner BOX Assembly Connecting the Tiss System InstructionsEnd View Angle Mounted Heaters only GAS Connections and Regulations Do not USE AN Open Flame of ANY Kind to Test for LeaksKEY Dimensions and Components of the GAS Connections Instructions for Pressure Test Gauge Connection Supply PressureManifold Pressure Combination GAS Valve is Factory SET Electrical Connections STEP-OPENING GAS Control ValvePS/W Ignition Module Terminal Designations 24VAC/RTH/W GNDLine Voltage 120V Thermostat Connections Single Heater Line Voltage 120V Thermostat Connections Multiple HeatersLOW Voltage 24V Thermostat Connections Single Heaters Venting Carbon Monoxide HazardSingle Heater Venting Vertical Through the Roof Single Heater Venting Horizontal Through Sidewall#10 Self-Drill Vent Pipe Screws Multiple Heater Vertical venting arrangement PTS/PTU Common Vent DiameterAIR for Combustion Direct Outside AIR for CombustionVertical Lighting and Shutdown Instructions Sequence of OperationBurner Component Locations Cleaning and Maintenance Electric Shock & Explosion HazardTroubleshooting Guide Form Form #43343330 May Replacing Parts Removal of Main Burner and ElectrodesRemoval of GAS Valve and Manifold Assembly AIR Switch Pressure CheckIgnition System Checks To Check Flame Sensor CircuitInstallation Data Ignition Module DiagnosticsReplacement Parts Guide Burner BOX FastenersLabels/Manual 22c 22b 22a 40a 17a Body Components Description