Gas-Fired Products PTU Series, PTS Series manual Burner Package Numbers, Natural GAS

Page 7

BURNER PACKAGE NUMBERS:

NATURAL GAS

MODEL NO

PART NO.

PTS/U 40-N5

#44149010

PTS/U 50-N5

#44149030

PTS/U 75-N5

#44149050

PTS/U 100-N5

#44149070

PTS/U 125-N5

#44149090

PTS/U 150-N5

#44149110

PTS/U 175-N5

#44149130

PTS/U 200-N5

#44149150

PROPANE GAS

MODEL NO

PART NO.

PTS/U 40-L5

#44149020

PTS/U 50-L5

#44149040

PTS/U 75-L5

#44149060

PTS/U 100-L5

#44149080

PTS/U 125-L5

#44149100

PTS/U 150-L5

#44149120

PTS/U 175-L5

#44149140

PTS/U 200-L5

#44149160

B) PTS 40-200 Body Package Descriptions

(Package Part Number is indicated on the outside of each corresponding carton.)

System Lengths

PTS Body Packages – Aluminized/Hot Rolled or

10 Ft.

20 Ft. pkg

30 Ft. pkg

40 Ft. pkg

50 Ft. pkg

 

Alumi-Therm/Hot Rolled

44134020

44135000

44136000

44137100

44138100

Part #

Each Body Package Includes:

Qty.

Qty.

Qty.

Qty.

Qty.

42912080

10 Ft. Tube with 24 Hole Flange (Aluminized)

1

1

1

-

-

42912169

10 Ft. Tube with 6 Hole Flange (Alumi-Therm)

-

-

-

1

1

41932101

10 Ft. Tube less Flanges (Hot Rolled)

-

1

2

3

4

43319100

Reflector, 9’ 11½”

1

2

3

4

5

30462980

Tube Coupling

-

1

2

3

4

43318000

Tube Hanger/Support Bracket, 13”

1

2

3

4

5

43980010

Wire Hanger

1

2

3

4

5

 

 

 

 

 

 

 

Body Fastener Kit (included in body packages)

42907280

42907190

42907200

42907210

42907220

42873000

U-Bolt

1

2

3

4

5

02127110

Hex Nut, 5/16-18

3

5

6

8

10

02189020

HWHSM Screw, #10-16 x ½” TEKS

4

8

10

14

18

60Ft. System

 

 

40 Ft. Pkg

20 Ft. Pkg

PTS Body Packages – Alumi-Therm/Hot Rolled

44137100

44135010

Part #

Each Body Package Includes:

Qty.

Qty.

42912169

10 Ft. Tube with 6 Hole Flange (Alumi-Therm)

1

-

41932101

10 Ft. Tube less Flanges (Hot Rolled)

3

2

43319100

Reflector, 9’ 11½”

4

2

30462980

Tube Coupling

3

2

43318000

Tube Hanger/Support Bracket, 13”

4

2

43980010

Wire Hanger

4

2

 

 

 

 

Body Fastener Kit (included in body packages)

42907210

42907190

42873000

U-Bolt

4

2

02127110

Hex Nut, 5/16-18

8

5

02189020

HWHSM Screw, #10-16 x ½” TEKS

14

8

70Ft. System

40 Ft. Pkg.

30 Ft. Pkg

44137100

44136040

Qty.

Qty.

1

-

3

3

4

3

3

3

4

3

4

3

 

 

42907210

42907200

4

3

8

6

14

10

 

Form #43343330

–6–

May 08

Image 7
Contents Installation and Operation Instructions Table of Contents General Information SafetyInstaller Responsibility Installation RequirementsHigh Altitude For Canada onlyMinimum Clearances to Combustibles Minimum Clearances to CombustiblesPTS/PTU Packing List SpecificationsNatural GAS Burner Package NumbersPTU 40-200 Body Package Descriptions Reflector, 4’ 11 ½’ End Reflector Accessory Package AccessoriesExhaust Hood Package Emitter Length Body Length Model Typical Layouts PTU / PTS SeriesPoisonous GAS and Soot Hazard Typical Assembly LayoutPTS Series Dimensions PTU Series Joining of Tube Sections Heater AssemblyTypical Assembly Overview PTU 40FT Shown Suspension Hazard Typical Suspension MethodsCUT Hazard Assembly of Tube SectionsMIN 8’ MAX 10’ Between Hangers Assembly of Extension SectionInserting Turbulators Adding Reflectors Assembly HazardAdding Optional Corner Reflector PTS only Adding Optional 90º Elbow PTS onlyAdding Optional U-BEND Reflector PTU only Adding 180U-Bend PTU onlyAttaching Burner BOX Assembly Instructions Connecting the Tiss SystemEnd View Angle Mounted Heaters only Do not USE AN Open Flame of ANY Kind to Test for Leaks GAS Connections and RegulationsKEY Dimensions and Components of the GAS Connections Supply Pressure Instructions for Pressure Test Gauge ConnectionManifold Pressure Combination GAS Valve is Factory SET STEP-OPENING GAS Control Valve Electrical ConnectionsGND Ignition Module Terminal Designations 24VAC/RTH/W PS/WLine Voltage 120V Thermostat Connections Multiple Heaters Line Voltage 120V Thermostat Connections Single HeaterLOW Voltage 24V Thermostat Connections Single Heaters Carbon Monoxide Hazard VentingSingle Heater Venting Horizontal Through Sidewall Single Heater Venting Vertical Through the Roof#10 Self-Drill Vent Pipe Screws PTS/PTU Common Vent Diameter Multiple Heater Vertical venting arrangementDirect Outside AIR for Combustion AIR for CombustionVertical Sequence of Operation Lighting and Shutdown InstructionsBurner Component Locations Electric Shock & Explosion Hazard Cleaning and MaintenanceTroubleshooting Guide Form Form #43343330 May Removal of Main Burner and Electrodes Replacing PartsAIR Switch Pressure Check Removal of GAS Valve and Manifold AssemblyTo Check Flame Sensor Circuit Ignition System ChecksIgnition Module Diagnostics Installation DataFasteners Replacement Parts Guide Burner BOXLabels/Manual 22c 22b 22a 40a 17a Description Body Components